ZR-KX-GVPVP/R compensation wire cable
This product complies with the equivalent of GB/4989-94 and adopts the IEC584-3 standard
The flame retardant properties comply with the requirements of GB/T18380.3 (IEC60332-3).
The function of compensating wires for hotspots is to extend the cold end of thermocouples and connect them with thermometers to form a temperature measurement system. The product adopts polyvinyl chloride insulation and sheath, which has excellent moisture-proof, wear-resistant, and flame-retardant properties.
Basic model and name
model
product name
ZR-KX-GsVV
Flame retardant polyvinyl chloride insulated and sheathed precision single stranded conductor, compensating wire for K-index thermocouple
ZR-KX-GsVVR
Flame retardant polyvinyl chloride insulation and sheath precision grade multi strand conductor, compensating flexible wire for K-index thermocouple
ZR-KX-GsVVP
Flame retardant polyvinyl chloride insulation and sheath, precision grade single stranded conductor copper wire braided shielding, compensating cable for K-index thermocouple
ZR-KX-GsVVRP
Flame retardant polyvinyl chloride insulation and sheath, precision grade single stranded conductor copper wire braided shielding, compensating flexible cable for K-index thermocouple
ZR-KX-GsVPVP
Flame retardant polyvinyl chloride insulation and sheath precision grade single stranded conductor copper wire braided split screen, total screen, compensating cable for K-index thermocouple
ZR-KX-GsVPVRP
Flame retardant polyvinyl chloride insulation and sheath precision grade single stranded conductor copper wire braided split screen, total screen, compensating flexible cable for K-index thermocouple
ZR-KX-GsVVPl
Flame retardant polyvinyl chloride insulation and sheath precision single stranded conductor aluminum-plastic composite tape wrapped shielding, compensating cable for K-index thermocouple
ZR-KX-GsVVRPl
Flame retardant polyvinyl chloride insulation and sheath precision grade single stranded conductor aluminum-plastic composite tape wrapped shielding, compensating flexible cable for K-index thermocouple
ZR-KX-GsVPlVPl
Flame retardant polyvinyl chloride insulation and sheath, precision grade single stranded conductor aluminum-plastic composite tape wrapped and divided screen, compensating cable for K-index thermocouple
ZR-KX-GsVPlVRPl
Flame retardant polyvinyl chloride insulation and sheath, precision grade single stranded conductor aluminum-plastic composite tape wrapped and divided screen, compensating flexible cable for K-index thermocouple
ZR-KX-GsVVP2
Flame retardant polyvinyl chloride insulation and sheath precision single stranded conductor copper plastic composite tape wrapped shielding, compensating cable for K-index thermocouple
ZR-KX-GsVVRP2
Flame retardant polyvinyl chloride insulation and sheath precision single stranded conductor copper plastic composite tape wrapped shielding, compensating flexible cable for K-index thermocouple
ZR-KX-GsVP2VP2
Flame retardant polyvinyl chloride insulation and sheath precision grade single stranded conductor copper plastic composite tape wrapped and divided screen total screen, compensating cable for K-index thermocouple
ZR-KX-GsVP2VRP2
Flame retardant polyvinyl chloride insulation and sheath, precision grade single stranded conductor, copper plastic composite tape wrapped and divided screen, compensating flexible cable for K-index thermocouple
Detailed introduction:
▲ Implementation standard: GB/T4989/94 is equivalent to IEC584.3
▲ Purpose: Suitable for temperature control systems in energy, metallurgy, petroleum, chemical and other industrial enterprises and research departments. It is used for connecting the cold end of temperature measuring instruments and between temperature measuring instruments. The heat-resistant type adopts imported fluoroplastic insulation and sheath, which has excellent heat resistance, waterproof, anti-corrosion, acid and alkali resistance, chemical resistance, wear resistance, aging resistance and non combustion performance. The operating temperature ranges from -60 to 205 ℃, which is at the international advanced level.
▲ Usage characteristics: Compensation cable usage characteristics
Type: Minimum bending radius, minimum temperature, maximum temperature
Unarmored, armored, fixed installation, non fixed installation
general type
There is "105" in the model“
There is "90" in the model“
High temperature cable outer diameter 6 times
Cable outer diameter 10 times cable outer diameter 12 times ≥ -40 ℃
≥-60℃ ≥-15℃
≥-20℃ ≤70℃
≤105℃
≤90℃
≤250℃