Langsongkeli (Shanghai) Instrument Co., Ltd
Home>Products>ZMJ100XD density relay
ZMJ100XD density relay
Product Overview: Used to monitor the density of SF6 gas in sealed containers, it can display the gas density on site and alarm when the density value
Product details

product overview

Used for monitoring sealed containersSF6The density of gas can be displayed on site, and an alarm will be triggered when the density value reaches the set value. It is suitable for detecting high-pressure systems. We can provide various solutions such as supporting new substations and intelligent transformation of existing substations.


Application scope

SF6Insulated composite electrical appliances(GIS

SF6Insulated Circuit Breaker

SF6Insulated pole switch

SF6insulating transformer

SF6Insulation Transformer

SF6Insulated busbar system


Product Features

1. Using gas compensation for higher set point accuracy

2. full scale1Level precision display.

3. Suitable for different installation needs indoors and outdoors

4. Micro switch, capable of freely switching between normally open and normally closed points

5. Up to four pairs of nodes, capable of achieving dual alarm and dual lockingWaiting for multiple options for safer and more reliable monitoring

6. High seismic resistance

7. No need for oil filling, no oil leakage hazard

8. Normally closed contacts will not give false alarms due to vibration


Technical Parameter

1. Measurement range:-0.1~0.9MPa

2. Set point accuracy1Grade(±10 kPa@ –30...+50 °C

3. Indication accuracy:1Grade(±10 kPa@ 20 °C

4. Protection level:IP65

5. Working temperature:-40°C~ +60°C,Relative humidity ≤95%RH

6. Leakage rate: 1×10-9 Pa·m3/s(Helium leak detection)

7. Interface size:M20×1.5(Customizable)

8. Installation method: radial or axial

9. Electrical connection:Connect the plug when it is pluggable, wire diameter0.2...2.5 mm2

10. Insulation performance: Insulation resistance:>100 MW(DC 500V)

Power frequency withstand voltage:2kV, 50/60 Hz, 1min

11. Contact type: Micro switch

12. Impact level:50g

13. Contact electrical parameters:30W/50VA, 1A.(Maximum)

220VDC/380V 50/60Hz(maximum)

14. Table glass: multi-layer safety glass

15. Weight:1.0kg

16. Pressure sensing components: imported corrugated tube and Bowden tube


Optional features:

measuring range

A wider temperature range:-60°C~+60°C

detectableSF6AirN2SF6+N2Waiting for gas

Remote transmission function


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!