YTC2165 Transformer Field Error Comprehensive Tester
The YTC2165 transformer field error tester can measure any percentage of ratio and angle difference between 1% and 120% of current, and can directly m
Product details

Product Introduction:
The YTC2165 transformer field error tester can measure any percentage of ratio and angle difference between 1% and 120% of current. It can directly measure the transformation ratio of current transformer field testers and voltage transformer field testers, qualitatively measure the ratio and angle difference of voltage transformers, and measure the actual secondary load of current and voltage transformers in the field.
The YTC2165 transformer on-site error tester adopts a 320x240 large LCD full Chinese interface, and has the function of saving any measurement parameters and printing measurement results.

Product nickname:Transformer calibrator, fully automatic transformer calibrator, transformer on-site calibrator, transformer on-site error tester.

Product features:
1.
This instrument measures the ratio and angle difference of current transformers according to national standards, and can measure S-level measurement functions. It can also measure on-site 0.2S and 0.5S level current transformers; One measurement process can simultaneously test the standard error of the current transformer under the upper and lower limit loads.
2.The YTC2165 transformer on-site error comprehensive tester has a large screen LCD display with full Chinese prompts for automatic measurement, and the entire instrument operation process is simple; The instrument is small in size, easy to carry, and only requires a few people to quickly complete the measurement work.
3.The instrument can qualitatively measure voltage transformers: during measurement, the instrument applies a certain power frequency voltage to the primary side of the voltage transformer to measure its primary voltage and secondary induced voltage, and obtain the transformation ratio and polarity of the voltage transformer at that voltage.
4.The YTC2165 transformer on-site error comprehensive tester can measure the on-site secondary load of current and voltage transformers, and can measure the ratio and angle difference of current transformers under this load.
5.This instrument can measure the transformation ratio of unmarked current transformers or voltage transformers accurately, quickly, and stably without the need for additional current or voltage boosting sources.
6.The YTC2165 transformer on-site error comprehensive tester can store and print various measurement data, and can save various setting parameters in case of power failure.