|
Explanation: ① 24 bit A/D converter. It has an accuracy of 0.05% and a display resolution of 1/100000. The adjustable segmented measurement and control speed of 1 to 20 times per second meets the different application requirements of high resolution and measurement and control speed. There are 3 levels of adjustable display brightness. 16 segment polyline function. Equipped with maximum and minimum value memory function. The 3-point switch input and 4 buttons can be programmed separately to achieve specified functions. ② Anti interference design, suppressing fast pulse group interference and other electromagnetic interference generated by relays, contactors, etc. on site, with anti-interference capability reaching level III ③ Temperature drift (-20 ℃)~Within the range of 50 ℃: the internal reference of the instrument is less than 5ppm/℃; Thermocouples, thermistors, and DC mV inputs are all less than 10ppm/℃; If the input of DC current and DC voltage is less than 30ppm/℃, and the user has high requirements for the temperature drift of these two signals, special customization can be proposed when ordering. ④ The input signal includes: thermistor (Pt100, Pt1000), with a temperature measurement range of -200.00 ℃~500.00℃; Thermocouples (K, S, E, T) with a resolution of 0.1 ℃; Direct current; DC voltage; DC mV ⑤ Panel size: 96 × 48 ⑥ Instrument power supply 220V AC Basic Configuration Single display(5Position redLED) Extended features ① Alarm output:2point ② transmitter output ③ External ordinary power supply (to power the transmitter):24Vor12V or 5V External precision power supply (supplying power to sensors such as load and pressure sensors)10Vor12V Or 0.5~1.5mA External precision constant current power supply: general1.28mA ④ communication interface:RS 485 or RS 232 ⑤ Printing interface
Note: Only one of the communication interface and printer interface can be selected
|
content
|
Code and Description
|
|
XSE6/
|
Single display, 5-digit red LED
|
|
|
C-
|
96×48×112(W×H×L)
|
|
Panel form
|
H
|
horizontal format
|
|
input signal
|
E
|
thermocouple
|
|
R
|
Thermistor or resistance
|
|
I
|
direct current
|
|
V
|
DC voltage
|
|
M
|
MV signal
|
|
Number of alarm points
|
T□
|
TO: No alarm T1~T2: 1~2 point alarm
|
|
transmitter output
(Independent power supply, fully isolated.
12 bits of D and A, with an error of less than ± 0.2% FS;
16 bit transmission output can be ordered with an error of less than ± 0.04% FS
|
A0
|
No output
|
|
A1
|
Current output (4~20) mA, (0~10) mA, or (0~20) mA
|
|
A2
|
Voltage output (0~5) V, (1~5) V
|
|
A3
|
Voltage output (0~10) V
|
|
A4
|
Other outputs
|
|
external power supply
|
B0
|
No external power supply
|
|
B1
|
External supply 24V DC
|
|
B2
|
External supply 12V DC
|
|
B3
|
External precision voltage source
|
|
B4
|
External precision constant current source
|
|
B5
|
other
|
|
communication interface
(Independent power supply, fully isolated, 24009.2K)
Instrument address 0.99, response delay less than 500Us)
|
S0
|
No communication interface
|
|
S1
|
RS-232 interface
|
|
S2
|
RS-485 interface
|
|
instrument power supply
|
V0
|
85V AC~265V AC
|
|
Printing function (printing function cannot coexist with communication interface)
|
P
|
P ribbon printing function
|
|
P1
|
Indicating the presence of an integrated printer
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: * Level III - Suitable for typical industrial environments. The places where industrial process equipment is used, such as power plants, outdoor high-voltage substations, relay rooms, etc., can serve as representatives of such environments.
Level II - Suitable for protected environments. The control rooms or terminal rooms of factories and power plants can serve as representatives of such environments.
Grade I - Used in environments with good protection. The computer room can serve as a representative of such environments.
*85V~265V AC
Explanation: ① 24 bit A/D converter. It has an accuracy of 0.05% and a display resolution of 1/100000. The adjustable segmented measurement and control speed of 1 to 20 times per second meets the different application requirements of high resolution and measurement and control speed. There are 3 levels of adjustable display brightness. 16 segment polyline function. Equipped with maximum and minimum value memory function. The 3-point switch input and 4 buttons can be programmed separately to achieve specified functions.
② Anti interference design, suppressing fast pulse group interference and other electromagnetic interference generated by relays, contactors, etc. on site, with anti-interference capability reaching level III
③ Temperature drift (within the range of -20 ℃~50 ℃): The internal reference of the instrument is less than 5ppm/℃; Thermocouples, thermistors, and DC mV inputs are all less than 10ppm/℃; If the input of DC current and DC voltage is less than 30ppm/℃, and the user has high requirements for the temperature drift of these two signals, special customization can be proposed when ordering.
④ The input signal includes: thermistor (Pt100, Pt1000), with a temperature measurement range of -200.00 ℃ to 500.00 ℃; Thermocouples (K, S, E, T) with a resolution of 0.1 ℃; Direct current; DC voltage; DC mV
Basic technical specifications
Power supply: 85V AC~265V AC, power consumption less than 8W;
Working environment: 0 ℃~50 ℃, humidity below 85% R.H
Display range: -19999~99999, decimal point position can be set
Display color: red, display brightness can be set to 3 levels
Display resolution: 1/100000
Input signal types: voltage, current, thermistor, thermocouple, mV, among which Voltage: 1V~5V DC, 0V~5V DC can be selected through setting Current: 4mA~20mA, 0mA~10mA, 0mA~20mA can be selected through setting Thermistor: Pt1000 or Pt100 must be specified when ordering
3-wire or 4-wire system selected through internal jumper of the instrument
Temperature measurement range: -200.00 ℃~500.00 ℃
Thermocouples: K (0~1350.0 ℃), S (0~1750.0 ℃), E (0~800.0 ℃), T (0~400.0 ℃) can be selected by setting, with a resolution of 0.1 ℃
MV signal: 30mV, 60mV, 120mV can be selected through setting
Basic error: less than ± 0.05% F.S
Measurement resolution: 24 bit A/D converter
A/D conversion rate: 20 times/second
Measurement and control speed: 1 time/second, 5 times/second, 10 times/second, 20 times/second, 4 levels to choose from
Technical specifications for selected accessories
alarm output
Relay output: Contact capacity 220V AC, 3A
OC gate output (specified when ordering): voltage less than 30V, current less than 50mA
transmitter output
- Optoelectronic isolation
-4mA~20mA, 0mA~10mA, 0mA~20mA DC current output, selected through setting. Load capacity greater than 500 Ω
-1V~5V, 0V~5V, 0V~10V DC voltage output, please specify when ordering
- Output resolution: 1/3000, error less than ± 0.2% F.S
16 bit transmission output can be ordered with an error of less than ± 0.05% F.S
communication interface
- Optoelectronic isolation
RS232 and RS485 standards, please specify when ordering
- Instrument address 0~99 can be set
- Communication rates of 1200, 2400, 4800, 9600, and 19200 can be selected through setting. Rates lower than 1200 should be specified when ordering
- Delay in the response of the instrument from receiving computer commands to sending corresponding data: The command with "#" as the delimiter has a response delay of less than 500 μ s; The response delay for other commands is less than 50ms
- Supporting testing software, providing technical support for configuration software and application software
Printing interface and printing unit
- Built in hardware clock, power outage does not affect timekeeping, automatically adjusts leap years, major and minor months
The printing content can be set as measured value, maximum value, and minimum value
The printing method can be set to manual printing or timed printing
external power supply
- Ordinary power supply: used to power the transmitter, with a small error between the output value and the nominal value At ± 5%, with a load capacity greater than 100mA
- Precision constant voltage source: used to supply power to strain sensors such as pressure and load, and output
The error between the value and the nominal value is less than 0.1%, and the load capacity is greater than 40mA
- Precision constant current source: generally 1.28mA, used to supply power to diffused silicon pressure sensors
|