WTW Turb 550IR Scattering Turbidity Meter (Flow Tank Measurement)Product Introduction:

638094609642784280528.jpg

The laboratory turbidity measuring instrument adopts the 90 ° scattered light turbidity method, with automatic 3-point calibration, RS232 output and built-in real-time clock. The calibration interval can be set to remind the user when to check. The testing range is wide, ranging from 0.01... 1000 NTU, with automatic range switching. The dual row display screen can simultaneously display the current test value and previous test values for easy comparison. The Turb 550IR light source is an infrared LED light that complies with ISO 7027/DIN 27027 regulations.


Concise operation card, 3 empty test tubes, 3 AMCO standard solutions (0.02-10.0-1000 NTU), and test tube wiping tool. AMCO standard solution is certified according to USEPA and EN ISO7027 standards as a first-class standard for drinking water. A non pressure flow slot adapter can be used for continuous measurement.



WTW Turb 550IR Scattering Turbidity Meter (Flow Tank Measurement)Product features:


1. Test range 0.01 to 1000 NTU;

2. Automatic range switching;

3. Automatic 1-3 point calibration;

4. Flow channel measurement;

5. RS232 output;

6. Real time clock.


Technical parameters:


model Turb 550IR
measuring principle 90°Scattered light turbidity method
Lighting infraredLED
measure
range
NTU 0 one thousand
FNU 0 one thousand
EBC
Nephelos
FAU
resolution 0.01 NTU from 0.00 ... nine point nine nine
0.1 NTU from 10.0 ... ninety-nine point nine
1 NTU from 100 ... one thousand
accuracy ±2%Measurement value or±0.01 NTU
repeatability ±1%Measurement value or±0.01 NTU
correct 1-3 point automatic calibration
reaction time < 3second
Colorimetric tube 28 x 70 mmCircular colorimetric tube, 25 mlSample Volume
AQAfunction Calibration interval monitoring
Generate calibration records after calibration is completed
operate temperature +10 ... + 40 °C
power supply 100 - 240 VAC ±10% / 47 - 63 Hz





Turb 550IR Red light laboratory turbidity meter, containing calibration solution (0.02-10.0-1000NTU)and2An empty test tube, optional: continuous measurement slotD-Turb(600600) 600110