Advantages and Characteristics
• Measurement range of 0.5~65m/s, maximum allowable error ± 0.5m/s
• Contains precision signal processing unit and supports online calibration
New optoelectronic coupling design with high sensitivity and dynamic response characteristics
• Supports pulse signal output with optoelectronic isolation
• Supports RS485 digital signal output
Compact all aluminum body, supporting anti freezing and anti heat functions
Product specifications and parameters
|
Wind speed measurement range |
0.5~65m/s |
|
threshold wind velocity |
<0.5m/s |
|
Transform feature function |
U=0.1 × R+0.32 (U=wind speed [m/s], R=output pulse frequency [Hz]) |
|
maximum permissible error |
±0.5m/s |
|
resolution |
±0.1m/s |
|
Install the outer diameter of the wind rod |
50mm/52mm |
|
working power supply |
5~24VDC, 20mA/1A (heating on) |
|
output |
Optoelectronic isolation pulseRS485 |
|
Sensor output level |
1<+5mA high state>Uin-1.5V |
|
Working temperature during heating |
-50~55℃(-58~131℉) |
|
Storage temperature |
-60~70℃(-76~158℉) |
|
material |
Shell: Aluminum alloy |
|
Size(mm) |
240(h)×185(Φ)mm |
|
Wind cup turning radius |
64mm |
|
Wind cup diameter |
54mm |
|
weight |
500g |
|
Safety Certification |
CE |