| Instructions: |
|
application
Specially designed for the petrochemical sector, it can directly measure the surface temperature of liquids, vapors, gases, and solids within the range of -200 ℃ to 1600 ℃.
working principle
The two electrical levels of a thermocouple are composed of different conductor materials. When there is a temperature difference between the measuring end and the participating end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.
Product execution standards
IEC584
IEC751
IEC1515
JB/T5582-91
JB/T5518-91
Nominal Pressure
Generally refers to the static external pressure that the protective tube can withstand at room temperature without breaking. The allowable working pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, and the flow rate and type of the measured medium.
Temperature measurement range and allowable deviation
thermocouple
|
model
|
graduation mark
|
Tolerance level
|
|
Ⅰ
|
Ⅱ
|
|
Allowable deviation
|
Temperature measurement range ℃
|
Allowable deviation
|
Temperature measurement range ℃
|
|
WRN
|
K
|
±1.5℃
|
-40~+375
|
±2.5℃
|
-40~+333
|
|
±0.004 │t│
|
375~1000
|
±0.0075 │t│
|
333~1200
|
|
WRE
|
E
|
±1.5℃
|
-40~+375
|
±2.5℃
|
-40~+333
|
|
±0.004 │t│
|
375~800
|
±0.0075 │t│
|
333~900
|
|
WRP
|
S
|
±1℃
|
0~+1000
|
±1.5℃
|
0~600
|
|
±(1+0.003
(t-1100))
|
1000~1600
|
±0.0025 │t│
|
600~1600
|
|
WRQ
|
R
|
±1℃
|
0~+1100
|
±1.5℃
|
0~1100
|
|
±0.004 │t│
|
1100~1600
|
±0.0025 │t│
|
1100~1600
|
|
WRR
|
B
|
-
|
-
|
-
|
-
|
|
-
|
-
|
±0.0025 │t│
|
600-1700
|
|
|
|