English

Yongjia County Marine Water Pump Factory
Home>Products>WQK/QG unobstructed cutting cutter submersible sewage pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13676799385
  • Address
    No. 8 Linpu Road, Zhangbao Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province
Contact Now
WQK/QG unobstructed cutting cutter submersible sewage pump
The WQK/QG non clogging cutting cutter submersible sewage pump has a particularly strong sewage discharge capacity, with good cutting performance. It
Product details

Model Meaning
WQK/QG无堵塞切割绞刀式潜水排污泵型号意义

Product Introduction
The WQK/QG non clogging cutting cutter submersible sewage pump has a particularly strong sewage discharge capacity, with good cutting performance. It can chop up impurities such as long fibers, plastics, paper, belts, cloth strips, straw, ropes, etc. in the sewage and discharge them. Designed with reasonable hydraulic characteristics, the electric pump can operate at full head. The excellent combination of dry motor and water pump makes the total efficiency of the electric pump reach the same level as the ASS cutting device series products of West German ABS company. The electric pump adopts high-quality hard alloy, double end mechanical seal and skeleton oil seal assembly surface, which should not exceed 1/2 of the height of the motor, and the temperature of the pumped waste should not exceed 40 ℃.

Product Features
The WQK/QG non clogging cutting cutter submersible sewage pump is mainly used for discharging domestic wastewater, sewage, human feces and urine, as well as solid suspended solids and non corrosive media containing short fiber paper scraps, sawdust, starch, sediment, ore particles, etc. The temperature of the pumped liquid does not exceed 40 ℃, the density is not greater than 1200kg/m3, and the pH value is about 9. This electric pump adopts a double end mechanical seal and a rotating impeller. The impeller is made of stainless steel, wear-resistant, non clogging, non winding, and has the advantages of small volume, compact structure, and easy portability.

application
The WQK/QG unobstructed cutting cutter submersible sewage pump is mainly used for engineering sewage and domestic sewage.
For example: (1) Used for construction sites, engineering foundation construction, municipal facilities, and water treatment plants.
(2) Sewage discharge from the basement of various high-rise buildings, civil air defense pits, subways, and other underground structures.
(3) Sewage treatment and circulating water transportation for small and medium-sized enterprises.
(4) The pumping of slag and slurry from factories and mining enterprises such as food, paper, brewing, steel and non-ferrous metals, leather, textile, pharmaceutical, cement plants, etc.
(5) Chicken farms, pig farms, various animal husbandry industries, fish ponds are used for pumping and cleaning ponds, oxygenation, septic tanks, and other occasions for the transportation of human and animal manure and urine.
Note: The main performance and data of WQK are the same as those of WQK/QG type in terms of internal structure, except for the absence of cutting device.

Working conditions
(1) Before using the electric pump, it is necessary to first check whether the cables are damaged. When handling and installing the water pump, cut iron to pull or damage the cables to prevent accidents caused by cable breakage and water leakage. If the cable cracks hard, it should be replaced immediately. And use a megohmmeter to check if the insulation resistance of the electric pump is normal (the insulation resistance should not be less than 1 megohm)
(2) Identify the grounding wire (usually yellow or green or marked with a grounding symbol), and follow the prescribed procedures to properly connect the grounding wire. Our factory's grounding wire is equipped with a grounding sign.
(3) Choose appropriate protectors (such as leakage protectors, air switches, phase failure overcurrent protectors, etc.) and do not directly connect them with knife switches.
(4) Connect the power cord according to the standard, test the power supply, check if the electric pump is running normally, and determine if the steering is correct. If the steering is incorrect, swap any two of the three power cords (note that the running time should not exceed half a minute).
(5) Install the water outlet connector and water outlet hose (or iron pipe), tie a rope on the handle of the electric pump (cable cannot replace the function of the hanging rope), place the electric pump into the pump to be pumped, connect the power supply, and it can be used.
(6) In order to ensure personal safety, it is strictly prohibited to install water operations (such as moving, inspecting, troubleshooting, etc.) near the electric pump during the operation of the electric pump. Contact with the electric pump is necessary to prevent accidents caused by electric pump leakage
(7) It is strictly prohibited to expose the entire electric pump to the water surface for long-term (or short-term) operation. The "on" and "off" of the electric pump should not be too frequent to prevent motor overheating and damage
(8) Long term pumping of liquids with high sand content causes significant wear on the overcurrent components of the WQK/QG belt cutting device sewage pump. It is recommended to use our factory's cyclone sewage submersible electric pump product.
(9) If it is found that the WQK/QG sewage pump with cutting device does not rotate, the protector trips, and the fuse burns out during operation, the power should be immediately cut off and the wiring of the power protector checked for any problems
If these external devices are all normal, it may be a fault with the electric pump, and it should not be continued to be used to avoid accidents!

performance parameter

model
caliber
Maximum flow rate
Maximum head
Motor Power
voltage
mm
m3/h
m
KW
v
WQK10-15-1.1
50
23
17
1.1
380
WQK15-9-1.1
65
30
15
1.1
380
WQK15-15-1.5
50
25
20
1.5
380
WQK20-12-1.5
65
35
18
1.5
380
WQK9-22-2.2
50
32
25
2.2
380
WQK25-12-2.2
65
45
21
2.2
380
WQK35-10-2.2
80
56
15
2.2
380
WQK15-25-3
50
35
30
3
380
WQK25-18-3
65
48
24
3
380
WQK35-13-3
80
60
18
3
380
WQK50-9-3
100
68
12
3
380
WQK15-32-4
50
40
36
4
380
WQK25-28-4
65
50
32
4
380
WQK40-18-4
80
65
27
4
380
WQK50-12-4
100
85
18
4
380
WQK18-34-5.5
50
43
40
5.5
380
WQK30-26-5.5
65
55
35
5.5
380
WQK40-24-5.5
80
70
30
5.5
380
WQK70-10-5.5
100
95
22
5.5
380
WQK100-7-5.5
150
120
12
5.5
380
WQK45-24-7.5
80
85
35
7.5
380
WQK70-18-7.5
100
110
30
7.5
380
WQK100-12-7.5
150
152
20
7.5
380

Fault analysis and troubleshooting methods

Fault phenomenon
Reason for malfunction
solution
The electric pump is not running
The power cord is not properly connected
Connect the power supply according to standard requirements
One phase of the power supply is not powered on
Check the fuse and power supply, connect the three-phase power supply
Impeller and chassis stuck
Adjust the chassis clearance between 0.2-0.5mm so that the impeller can be easily moved by hand
Electric pump burnt out
Repair the motor again
Damaged protective device
Repair or replace
Small water output
Insufficient head
The clearance between the impeller and the chassis is too large
Adjust the gap to the normal range (0.2-0.5mm)
The impeller is severely worn out
Replace the impeller
The motor speed cannot reach the normal speed
Replace the motor rotor or repair the voltage
The power supply voltage is too low
Adjust the voltage to the rated voltage
Reduce the voltage drop on the power leads of large cross-section cables (in the case of excessively long power leads)
Reverse rotation of electric pump
Swap the two power connectors to make the electric pump rotate forward
Cannot cut impurities
Poor cutting effect
The clearance between the impeller and the chassis is too large
Adjust the gap to the normal range (0.2-0.5mm)
Cutting blade wear becomes pure
Replace the impeller and chassis
Protector knows to disconnect
Connected and then disconnected
Improper selection or damage of protector
Re select a suitable protector (the rated current of the protector must match the rated current of the electric pump)
The insulation resistance of the power motor is too low (less than 0.5M Ω) due to moisture or water leakage
Remove the motor for drying. If the mechanical seal, sealing ring, or cable sealing head is damaged and leaks water, the damaged sealing components should be replaced
Short circuit between turns of motor stator coil
Replace or repair the motor again
Two phase operation of motor
Check the power supply or connectors, repair them
The power supply voltage is too low
Restore the voltage to normal value
The electric pump is stuck by impurities
Clean up impurities
Excessive viscosity or sand content in water can cause overload operation of the electric pump
Reduce viscosity or sand content
Bearing damage
Replace bearings


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!