MSQ8100Volatile organic compound detectioninstrumentBy combining efficient single quadrupole mass spectrometry with advanced GC1290 gas chromatography, we provide customers with high-quality analytical capabilities and performance.
The unique multi-core parallel processing technology and innovative ion source structure ensure excellent sensitivity under high-speed scanning, quickly obtaining qualitative and quantitative information of each component in complex samples, effectively improving analysis efficiency, and achieving rapid GC/MS analysis.
MSQ8100Volatile organic compound detectioninstrumentcharacteristic:
Excellent quadrupole design and performance
The quadrupole used in the MSQ8100 gas chromatography-mass spectrometer is a specially designed long rod structure for high-performance analysis, with excellent resolution and mass axis stability, providing high ion transport efficiency. The performance and reliability of the new processing technology achieved through the development of national major scientific instruments and equipment.
The detector has high resolution and long-term stability throughout the entire mass range (up to 1100u).
Innovative ion source structure design improves instrument performance
The MSQ8100 gas chromatography-mass spectrometer uses an innovatively designed curved repulsion electrode, which has superior electric field distribution and smoothness compared to a flat repulsion electrode, improving ion generation efficiency and migration efficiency, achieving better sensitivity and stability, and enhancing the overall performance of the instrument.
High speed electronic circuits enhance instrument performance and achieve full range Scan data acquisition
Because only Scan can perform spectral library retrieval, Scan has more advantages than SIM mode. The MSQ8100 design utilizes high-speed electronic circuit design, significantly improving data transmission speed with a scanning speed of up to 30000 u/sec, making full range scanning possible in GC-MS detection without sacrificing instrument analysis performance, making customer applications more convenient.

GC/MS software suitable for various workflows and applications
A fully functional customized Clarity software that fully supports GLP/FDA-21CFR Part 11 electronic signature authentication, making the operation more user-friendly and convenient.
A fully Chinese workstation software that adopts task and method modes, providing flexible and versatile combinations suitable for various workflows and applications.
The graphical interface and good human-computer dialogue make it easy to learn and master, and non professionals can also quickly master software usage.


Advanced gas chromatograph
The MSQ8100GC/MS gas chromatography-mass spectrometer is used to prepare the GC1290 gas chromatograph, which adopts advanced EPC electronic gas path control and high-precision temperature control. Combined with optimized column temperature box and sampler design, it provides an excellent chromatographic separation system, taking GC/MS to a new level.
A fully automated gas chromatograph that can be controlled and managed by a microcomputer from sample import to analysis report. Large touch screen setup and display, user-friendly interface, and simple operation. At the same time, the high reliability design reflects excellent quality performance, greatly improving analysis efficiency.
New EPC electronic pneumatic control
The integrated EPC module ensures precise and stable control of flow and pressure, and digitally controls the gas path parameters of the sampler and detector, ensuring the accuracy and reproducibility of the analysis results.
5 EPC modules can be installed simultaneously to achieve EPC control for 12 channels. And with standardized atmospheric pressure and temperature compensation, environmental changes will not affect the detection results, making it more suitable for use with mass spectrometry detectors to ensure excellent retention time repeatability accuracy.
Large volume sampler

Large volume sampler - used in conjunction with GC/MS, the detection sensitivity is increased by 10-100 times.
Unique "gastric bag" liner, capable of withstanding a sample injection volume of 200 μ l at high energy.
Significantly increase the detection limit of pesticide residue methods.
Reduce the sampling volume or eliminate the concentration step, accelerate the pre-processing process, and improve analysis efficiency.
Multi functional automatic sampling system

● Powerful sample pre-processing and automatic injection platform.
Standard liquid injection module, optional headspace injection and thermal desorption modules.
A 162 bit x2mL sample processing platform with expandable sample grades.
Blow and capture sample concentration system

The Eclipse 4760 blow and capture system from OI company, matched with MSQ8100 GC/MS, provides services for volatile organic compounds (VOCs) in water/soil.
Optional: 4551A (water sample) and 4100 (water/soil sample) automatic sampler.