Equipment name |
Hot air circulation drying oven |
||||||
|
Factory model: |
TSCD-3500 |
Working temperature range: |
room temperature+10~260℃ |
||||
|
Voltage used: |
380V/N+3+land/50HZ |
Temperature control accuracy: |
±1℃ |
||||
|
Heating power: |
21KW |
Temperature uniformity: |
±2.5%℃ (unloaded) |
||||
|
Blast power: |
750W/380V*2group |
|
|
||||
|
Specifications and dimensions: |
|||||||
|
Studio size: |
1950*1200*1300MM |
deep*wide*High(mm) |
|||||
|
Overall dimensionsabout: |
2150*1640+210(Control box size)*1690+270(Motor height) |
deep*wide*High(mm) |
|||||
|
Material for box production: |
|||||||
|
Outer wall material of the box: |
A3The thickness of carbon steel cold rolled plate is1.0mmSheet metal bending, welding, and rivet splicing. |
||||||
|
Material of box air plate |
SUS304The thickness of stainless steel is1.0mmSheet metal bending machine punching. |
||||||
|
Box air duct material |
SUS304The thickness of stainless steel is1.0mmSheet metal bending, welding, and rivet splicing. |
||||||
|
Box frame material: |
8#channel steel |
||||||
|
Box reinforcement material: |
5#Angle steel, locally used2mmSteel plate bending |
||||||
|
Material of the bottom load-bearing frame of the box: |
6#channel steel |
||||||
|
Top frame material of the box: |
4#angle steel |
||||||
|
Thickness and material of insulation layer: |
100KHigh density aluminum silicate fiber filling with insulation layer thickness of90mm) |
||||||
|
Bottom fixed: |
Four iron feet fixed (optional movable casters and positioning feet) |
||||||
|
Outer box coating material: |
After rust prevention treatment, the surface is coated with environmentally friendly hammer pattern paint, and the color can be specified by the customer,Blue box, white door. |
||||||
|
Door production method: |
|||||||
|
Outer wall material: |
A3Cold steel plate sheet metal bending, welding, rivet splicing, surface coated with environmentally friendly hammer pattern paint |
||||||
|
Door inner wall material: |
SUS304The thickness of stainless steel is1.0mmSheet metal bending, welding, and rivet splicing. |
||||||
|
Number of doors: |
double door |
||||||
|
Door Buckle: |
Alloy hinges and upper and lower buckle pull rods |
||||||
|
Door frame sealing material: |
High temperature resistant silicone rubber sealing strip forced sealing (with good sealing performance and easy cleaning) |
||||||
|
Studio configuration:Stand up one,Vertical division20Ge,Shelf size:1870*1030*1280MM,spacing30MM. Suitable for graphite frame size:756*1110*25,1524*1100*25,1688*1160*25,1860*1000*25,1060*1000*25,1050*1000*25.
|
|||||||
|
exhaust system |
|||||||
|
Exhaust: |
aperture100mmThe air output can be manually adjusted1One, exhaust outward.side |
||||||
|
Circulating system: |
Forced circulation vertical belt horizontal air supply, hot air circulation avoids temperature blind spots inside the box. |
||||||
|
Blowing method: |
High temperature resistant extra long shaft oven motor with centrifugal fan blades2Set, power:750W*2Taiwan |
||||||
|
Motor device: |
top |
||||||
|
Heating element: |
All stainless steel tubular heating tube with long continuous service life.Quantity and power:3.5KW*6branch |
||||||
|
Notice during testing: |
The testing point should be at least away from the inner wall material120Millimeters, at least from the door100Millimeters. The testing time should be at least after reaching the temperature (constant temperature state)30minute. |
||||||
|
Standard electrical configuration: |
|||||||
|
Temperature control device: |
Digital display intelligent instrument XGQ-A2100FAutomatic temperature control, constant temperature and beltPIDAdjust. Control accuracy ±1℃. |
||||||
|
Overtemperature protection device: |
XGQ-D1100Digital intelligent instrument.Exceeding the specified temperature, the buzzer will sound an alarm and the heating will be cut off. |
||||||
|
Time setting device: |
HS48S-99.99Timer device, manually adjustable/Automatic switch, starts timing when the temperature reaches the set temperature, and cuts off the heating power when the time reaches the set range. |
||||||
|
Alarm device: |
APT/AD16Type sound and light alarm device, set end alarm prompt. |
||||||
|
Control circuit voltage: |
220V / 50HZ |
||||||
|
Temperature measuring device: |
Two stainless steel armorsKType temperature sensing device, precise temperature measurement. |
||||||
|
Protection system: |
Overtemperature protection, circuit breaker protection,Motor overload protection. |
||||||
|
Main control output: |
SSRSolid state relay output, contactor output |
||||||
|
Random spare parts: |
One copy of the user manual, one copy of the instrument manual, one copy of the warranty certificate, and one copy of the certificate of conformity. |
||||||
|
Warranty coverage: |
The product comes with a one-year warranty (excluding human damage) for all electrical components. |
||||||