Agilent Gas Chromatography GC6890N

Product model: 6890N
Technical Parameter
Technical specifications: Detector: FID detection limit<5pg carbon/s (propane) Column box Temperature control range: Room temperature+4 ℃~450 ℃ Split/non split capillary column Injection port pressure setting range: 0-100psi (optional 0-150psi) Split/non split capillary column Injection port total flow setting range: 0-200ml/minN2, 0-1000ml/minH2 or He
main features
Feature 1: Large volume injection, eliminating the need for sample concentration steps
2. Utilize simplified parameter input and system control to quickly set up methods
3. Comprehensive injection options: Split/No Split injection (0-100 psi and 0-150 psi), packed column injection, cold column head injection, programmed temperature vaporization injection port, and volatile substance analysis interface
4. A wide range of sensitive detector options in the industry, including flame ionization detectors, thermal conductivity detectors, miniature electron capture detectors, nitrogen phosphorus detectors, mass selective detectors, inductively coupled plasma mass spectrometry, and an improved flame photometric detector. The improved flame photometric detector is 5 times more sensitive to sulfur and 10 times more sensitive to phosphorus than the previous detector. Compared with the standard FPD, it has excellent sensitivity to both sulfur and phosphorus.
5. Other detectors available through Agilent partners include SCD, Pulse Flame Photodetector (PFPD), and Atomic Emission Spectrometer (AED)
6. Large volume injection eliminates the need for sample concentration steps
7. Built in Agilent 7683 automatic sampler control function. To achieve high efficiency, room temperature headspace, liquid-liquid extraction, and different ranges of injection volumes, you only need to simply add the injector and sample tray module
8. Optional injection techniques, including headspace injection, sweep capture, and valve injection
9. Various data processing options, including Agilent Petrochemicals QA/QC Cerity networked data system and Agilent ChemStation Plus series products (including ChemStore C/S and ChemAccess)
10. Equipped with all the functions of rapid gas chromatography, it can provide you with highly accurate and consistent results -10 times faster than standard gas chromatography
11. Built in compliance function
instrumentintroduce
The launch of Agilent's analytics solution is timely, as it can help you optimize your analytics process and meet the challenging needs of today's business environment. Agilent can provide customized, tested systems and solutions tailored to your specific chemical analysis application. We evaluate your business needs and design a solution that can help you achieve better business results, including instruments, accessories, parts, repairs, and any customized components needed. For your special application, we can also provide our developed, optimized, and tested methods based on your specific application. The equipment for Agilent Analytics Solution * is the 6890N network gas chromatograph (GC). The built-in local area network (LAN) enables you to share business and scientific data through your site for quick and accurate decision-making. Like its predecessor 6890 GC, this gas chromatograph has the flexibility and performance required for all industrial research and method development. This instrument is durable and reliable, suitable for conventional methods that require multiple chromatography columns or valves, specific injection ports or detectors, and a wide temperature range. This gas chromatography system provides proven fourth generation electronic gas path control, which can maintain constant pressure and flow settings during each operation. This technology supports retention time locking. In this way, on any other Agilent 6890 GC or 6850 GC with electronic gas path control, regardless of the operator, location, or detector column length, the retention time repeatability can be maintained within a few percent or a few thousandths of a minute. Features: 1. Large volume injection, eliminating the need for sample concentration steps. 2. Utilizing simplified parameter input and system control for rapid method setup. 3. Comprehensive injection options: split/non split injection (0-100 psi and 0-150 psi), packed column injection, cold column head injection, programmed temperature vaporization injection port, and volatile matter analysis interface. 4. Industry wide range of sensitive detector options, including flame ionization detector, thermal conductivity detector, micro electron capture detector, nitrogen phosphorus detector, mass selective detector, inductively coupled plasma mass spectrometry, and an improved flame photometric detector. The improved flame photometric detector is 5 times more sensitive to sulfur and 10 times more sensitive to phosphorus than the previous detector. Compared with the standard FPD, it has excellent sensitivity to both sulfur and phosphorus. 5. Other detectors available through Agilent partners include SCD, Pulse Flame Photodetector (PFPD), and Atomic Emission Spectrometer (AED). 6. Large volume injection eliminates the need for sample concentration steps. 7. Built in Agilent 7683 automatic sampler control function. To achieve high efficiency, room temperature headspace, trace liquid extraction, and different ranges of injection volumes, you only need to simply add an injector and sample tray module. 8. Optional injection techniques, including headspace injection, blowdown capture, and valve injection. 9. Various data processing options, including Agilent's petrochemical industry QA/QC Cerity networked data system and Agilent ChemStation Plus series products (including ChemStore C/S and ChemAccess). 10. With all the functions of rapid gas chromatography, it can provide you with highly accurate and consistent results -10 times faster than standard gas chromatography. 11. Built in regulatory compliance function

Updated on September 2, 2020 at 10:22:28

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!