Junqi Instrument Equipment (Shanghai) Co., Ltd
Home>Products>Used Agilent 1100 liquid chromatograph, binary low-pressure liquid chromatograph, Agilent liquid phase accessories
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18017027751
  • Address
    No. 293-295 Yexie Yexiao Road, Songjiang District, Shanghai
Contact Now
Used Agilent 1100 liquid chromatograph, binary low-pressure liquid chromatograph, Agilent liquid phase accessories
The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column f
Product details

Used Agilent 1100 liquid chromatograph, binary low-pressure liquid chromatograph, Agilent liquid phase accessories

The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional)

0.001-2.5m/min (EFC closed state)

High pressure preparation pump system, unit or dual high-pressure preparation pump

Flow rate range: 0.001-100m1/min

● Flow rate range of analytical pump system:

Unit pump: 0.001-10m3/min, binary pump: 0.001-5m3/min, quaternary pump: 0.001-10m3/min

Agilent 1100 series injection system with a complete range of varieties

Standard manual sampler (analytical or preparation type)

● Standard automatic sampler

Sample bottle capacity: up to 100 pieces (2mlx100)

Injection volume: 0.1-100ul (0.1-1800ul) optional

● Micro disc automatic sampler

Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml

Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional

● Micro standard automatic sampler/micro disc automatic sampler

Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)

● Constant temperature standard automatic sampler/micro disc automatic sampler

Temperature range: 4-40 ℃ with adjustable step size of 1 ℃

220 type microporous plate automatic sampler - combined chemical sample management system

Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes

Injection volume: 0.1-5ul; 0.1-20ul

Variable wavelength scanning ultraviolet detector (VWD) wavelength range: 190-600nm

Multi wavelength detector (MWD) wavelength range: 190-950nm (dual lamp source)

● Diode Array Detector (DAD)

Wavelength range: 190-950nm (dual light source)

Fluorescence detector (FID) excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum

Differential Refraction Detector (RID) Temperature Control: Room Temperature+5 ℃ to 55 ℃ Built in Automatic Purging Valve and Automatic Solvent Circulation Valve

Electrochemical detector (ECD)

LC/MS quadrupole mass detector (MSD)

LC/MS ion trap mass detector (Trap MSD)

Column temperature box and deaerator components

● Column temperature range: 10 ℃ to 80 ℃ at room temperature Optional: Column switching valve

Vacuum online deaerator

JunqiinstrumentequipmentA new batch of Agilent equipment has arrived, including Agilent 6890 gas chromatograph (equipped with single capillary FID detector; dual capillary FID detector, ECD detector); Agilent 6890N gas chromatograph single capillary FID detector; Equipped with automatic liquid sampler and sampling tower, with a hundred position sample tray; Agilent 7694 headspace sampler (44 stations fully automatic, 6 stations sample heating); Agilent 6890N+5973 gas chromatography-mass spectrometer GCMS Shimadzu QP2010 GCMS, Agilent LC-MS, AB (API) GC-MS, etc.

Before making a purchase, be sure to contact the small shopHelp you find the item you need at a suitable price

contact information 18017027751

www.junqi-sh.com

www.sh-junqi17.com

Specific configuration price, phone contact

Junqi Instrument's new chromatography equipment rental service is currently limited to customers in Jiangsu, Zhejiang, and Shanghai. The rented equipment includesAgilent 5890PGas chromatographAgilent 6890 gas chromatograph Agilent 6890N-5973 gas chromatography-mass spectrometry Yishimitsu QP-2010 gas chromatography-mass spectrometer details consultation Junqi Instrument 18017027751

Updated on September 2, 2020 at 10:22:27

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!