uv-visSolidSpec-3700 Product Introduction:
Fluorescence detectors are widely used in fields such as food, pharmaceuticals, and the environment. In these fields, the most important requirements for users are sensitivity and ability to handle ultra fast analysis in recent years. The Prominence RF-20A/20Axs adopts a newly designed optical system, achieving world-class ultra-high sensitivity and ultra fast analysis capabilities. Moreover, the position of the lamp and detection pool does not need to be adjusted, and can be replaced from the front, improving the convenience of device maintenance.
RF-20Axs has a cooling detection pool temperature control function that other companies do not have, utilizing temperature control near room temperature to provide excellent reproducibility. And it is equipped with a low-pressure mercury lamp for automatic wavelength confirmation.
Main Features
>> RF-20A
World class sensitivity: Water Raman peak signal-to-noise ratio of over 1200.
Fast response and sampling frequency (100 Hz, 10 ms) support UFLC analysis.
Replace the light and circulation pool from the front of the instrument without the need for position adjustment.
• Use the VP function to query usage time and manage logs.
>> RF-20AXS
World class sensitivity: Water Raman peak signal-to-noise ratio of over 2000.
The world's only temperature controlled testing pool equipped with cooling function.
Utilize the built-in low-pressure mercury lamp for automatic wavelength confirmation.
Application Data
High sensitivity analysis example
Compared with RF-10Axl, RF-20Axs has a sensitivity that is more than 10 times higher in the short wavelength region and more than 6 times higher in the long wavelength region, indicating a significant improvement in sensitivity.
•
Component name |
Measure wavelength |
S/Ncompare |
sensitivity ratio |
||
Ex |
Em |
RF-20Axs |
RF-10Axl |
||
anthracene |
250 |
380 |
176.5 |
9.7 |
18.2 |
naphthalene |
270 |
330 |
65.3 |
4.7 |
13.9 |
benzo[k]fluoranthene |
300 |
410 |
47.9 |
7.9 |
6.1 |
fluoranthene |
350 |
460 |
107.4 |
8.7 |
12.3 |
Indeno[1,2,3 cd]pyrene |
365 |
500 |
178.8 |
26.5 |
6.7 |
The temperature control function of the circulation pool provides excellent reproducibility

The analysis data of acridine shows that even under room temperature fluctuations, the temperature control function of the RF-20Axs flow cell can still ensure good analysis reproducibility.
*If there is no pool temperature control function, when the room temperature increases from 25 º C to 30 º C, the peak intensity decreases by 17.5% due to the increase in pool temperature. Under these conditions, the peak area reproducibility is (n=6) 6.3%. However, after using the temperature control function of the circulation pool, excellent reproducibility of 0.3% was achieved by maintaining a constant pool temperature of 25 º C under room temperature fluctuations.
Peak area fluctuation and reproducibility when room temperature changes from 25 º C to 30 º C