UV2300ultraviolet/Visible spectrophotometerProvides high performance, easy to use and reliable, with a wide range of applications. The resolution of 1.5nm meets the standards of the European Pharmacopoeia. In biochemical applications, it is possible to measure very small amounts of samples such as DNA, and a micro pool of 50ul can be selected.
UV2300ultraviolet/Visible spectrophotometercharacteristic:
High resolution monochromator;
UV2300 can achieve higher resolution due to the elimination of coma aberration in the Seya Namioka monochromator. The Seya Namioka monochromator is the most commonly used concave diffraction grating today. The diffraction grating in UV2300 was manufactured using a high-precision grating engraving machine from Japan
Better spectral bandwidth
The spectral bandwidth is 1.5mm, which meets the standards of the European Pharmacopoeia and enables more accurate measurements.
|
USB storage for storing and exchanging data
The UV2300 host has a built-in USB interface and File Manager file management software for data exchange. This interface can connect multiple brands of USB flash drives (USB flash drives) with large storage capacity, making it convenient for storing information. Optical systems have strong energy and good stability Dual beam dual detector design, good stability, short startup preheating time. Due to the presence of two detectors, light loss is reduced, light energy is stronger, baseline noise is lower, and analysis sensitivity is improved.
640 × 480 high-definition LCD display The calibration curve spectrum and test results can be displayed on a 640 × 480 high-definition LCD monitor, and the soft background light makes the displayed content easy to observe. The keyboard buttons are cleverly designed, allowing users to use fewer keys to complete desired operations and improve efficiency. Featuring multiple measurement modes such as wavelength scanning Measurement of photometric values: Concentration can be calculated using a line or multiple regression line as a calibration curve. Wavelength scanning: After measurement, the spectrum will be displayed; Various data processing techniques can be used; Repeated scanning can track the chemical reaction process. Time scan: displays the variation of its luminosity value over time at a single wavelength. This function can be used for enzyme reaction analysis. There are also various data processing techniques in time scanning. Multi wavelength photometric measurement: It can automatically perform tests for up to 6 wavelengths. If the required data is measured at a specific wavelength, full wavelength scanning can be avoided to achieve rapid measurement.
Full wavelength fast scanning The spectrum covers the ultraviolet/visible range of 190-1100mm, with a scanning speed of up to 3200nm/min. Whether it's scientific research or quality control for designing large quantities of samples, UV2300 can handle it with ease. Microcell system suitable for biochemical measurement *The optical design of the instrument ensures that it can use a 50ul micro cell device for micro sample analysis, especially in medical, biochemical experiments, and valuable sample testing. Built in 260/280nm ratio measurement function The determination of the 260/280nm ratio can be used for quantitative analysis of nucleic acids. GMP/GLP Wizard Function The built-in GMP/GLP wizard function can help users easily complete various operations required by GMP/GLP. Automatically record the time when the light is on. The lighting time of deuterium lamps, tungsten lamps, etc. is automatically recorded in the instrument's memory, and users can decide whether to replace the light source based on the displayed time consumed by the lamp. Fixed slot positioning light source When replacing the light source, simply plug it into the lamp holder without adjusting the light path. This way, even without the presence of manufacturer technicians, users can replace the light source themselves. The confirmation function of the instrument can real-time determine the current condition of the instrument UV2300 has a self checking function, which can ensure that the instrument operates under the best conditions. Parameters such as wavelength accuracy and early sound level can also be checked. Confirmation function: This function checks and confirms the performance of the instrument. Compare the measured value with the preset value. The parameters being checked are as follows: wavelength accuracy (656.1nm)、 Wavelength accuracy (486.0nm), wavelength repeatability, bandwidth, baseline smoothness, baseline stability, noise level. * Automatic calibration and diagnosis: During installation, many diagnostics and adjustments can be automatically performed, including memory checks, wavelength driver device checks, and wavelength accuracy checks at 656.1nm. Other automatic functions include using the D2 light to illuminate the line for wavelength correction. The lighting time of W1 and D2 lights can also be displayed to meet GLP requirements.
|
|
UV2300ultraviolet/Visible spectrophotometerHost software functionality
|
Measurement modes: quantitative calculation, wavelength scanning, time scanning, multi wavelength measurement
Ratio: (wavelength 260/280nm)
Correction factor calculation Proportional calculation Spectrum display data tracking Smooth curve AREA Data storage Automatic wavelength correction
|
Correction curve types: linear, quadratic Line and K-factor input Light source light on time Concentration unit input Printing of Spectral Calibration Curve Detecting peaks and valleys Expansion and contraction of coordinates differential Four operations between spectra Confirmation function Optical path length compensation |
UV2300ultraviolet/Visible spectrophotometerTECHNICAL INDEX
Wavelength range: 190-1100mm Spectral bandwidth: 1.5nm Wavelength accuracy: ± 0.3 nm Wavelength repeatability: ± 0.1 nm Range of photometric values: Abs: -3.000 to 3.000 %T:0~600%T Conc:0.000~9999 Accuracy of photometric values (NIST930 neutral color filter): ±0.002 Abs (0~0.5 Abs) ±0.004Abs(0.5~1.0 Abs) ±0.008Abs(1.0~2.0 Abs) ±0.3%T Repeatability of photometric values (NIST930 neutral color filter): ±0.001 Abs (0~0.5 Abs) ±0.002 Abs(0.5~1.0 Abs) ±0.004 Abs(1.0~2.0 Abs) ±0.15%T |
Scattered light: less than 0.05% (220nm NaCl, 340nm NaNO2) Baseline stability: 0.0003 Abs/h (500nm, after 2 hours of preheating) Noise level: 0.0003 Abs (500nm) Baseline smoothness: ± 0.002 Abs (190-1100nm)
Wavelength scanning speed: 10100200400800120024003600 nm/min
Response time: fast, medium, slow
Light source: W1 lamp, D2 lamp Light source switching: automatic switching, users can freely choose between 325-370nm Detector: Silicon Phototube Display: Liquid Crystal Display (LCD, 190 × 138mm) Printer interface: Standard (supports ESC/P, PCL3 language) Serial interface: Standard (RS-232C) Dimensions: 505 (W) × 705 (D) × 225 (H) mm Weight: 29kg Power supply: 1001152020230240V, 50/60HZ
Power consumption: 200VA
|
Rich attachments suitable for various applications and trace sample analysis
Automatic samplerThis automatic sampler can be controlled by the built-in processor of the host or by an external computer through the host, and can be automatically recognized by software. Extremely low sample size requirement, with sample recovery and other multiple functions. Combined with an automatic sampler, automatic analysis can be performed. Zui sample size: 0.6ml ◎ Residual amount: less than 1% Pool capacity: about 70ul ◎ Optical path value: 10mm Reference beam: 10mm rectangular cuvette |
|
Constant temperature automatic samplerThe design structure is the same as that of an automatic sampler. Using a semiconductor constant temperature device, the temperature is continuously adjustable, and the flow cell section can maintain precise constant temperature. Zui sample size: 0.6ml ◎ Residual amount: less than 1% Pool capacity: about 70ul ◎ Optical path value: 10mm Set temperature: 20-40 ℃ Reference beam: 10mm rectangular cuvette |
|
Thermostatic pool bracketConstant temperature water circulates in the pool rack to maintain a constant sample temperature. Operating temperature range: Room temperature to 40 ℃ Setting accuracy: ± 3 ℃ Attention: The constant temperature water circulation device and colorimetric cell are not included and need to be purchased separately. |
|
Trace pool rackSuitable for trace sample analysis in the fields of medicine and biochemistry. Wavelength range: 220-1000nm Repeatability of pool installation: within 1.3% T Baseline stability: within 0.005Abs (when using a 50ul micro pool) |
|
Constant temperature automatic six connected poolUsing a semiconductor constant temperature device, the temperature of the sample cell is continuously adjustable. Install 6 10mm optical path colorimetric dishes on one side of the sample beam, which can be automatically or manually switched. Pool switching error: ± 0.5% (at 100% T) Available sample pool: 10mm (not included) Temperature adjustable: 20-40 ℃ |
|
|
5 connected pool conversion bracket
Five rectangular cells can be installed on one side of the sample beam, and a micro cell baffle can be inserted into each cell (the sample cell and micro cell baffle need to be purchased separately).
|
|
|
Rectangular long pool rack
Rectangular pool available, optical path length: 10, 20, 30, 40, 100mm
|
|
Thin film rackUsed for measuring thin film type samples Film size: 25mm wide, 30-50mm high Beam hole: 10mm wide, 20mm high, can be used as a cylindrical colorimetric dish, length: 10, 20, 30, 40, 50, 100mm |
|
|
Cylindrical pool rack
Used for measuring cylindrical sample tanks Can use cylindrical colorimetric dishes, length: 10, 20, 30, 40, 50, 100mm
|
|
|
Glass filter holder
Used to measure the absorption and transmission of solid samples, such as glass filters.
|
|
Related product links:
UV1100Series UV/Visible spectrophotometer
UV2300ultraviolet/Visible spectrophotometer
VIS 7200Type visible spectrophotometer
AA6000atomic absorption spectrophotometer
buck scientificAtomic absorption spectrometer
AFS-3100Fully automatic dual channel hydride generation atomic fluorescence spectrophotometer
AFS-2202EDual channel hydride generation atomic fluorescence spectrophotometer