TA800 ammonia nitrogen rapid detection instrument, using the nano reagent comparison method, selecting water quality detection items, inlet
The solid-state cold light source emits a light source signal from the sensor, which is processed by a RAM processor to directly provide feedback on the sample concentration value, displayed in mg/L.
Detection Principle
The principle of ammonia nitrogen determination (Nessler's reagent method): Ammonia nitrogen in the form of free ammonia or ammonium ions reacts with Nessler's reagent to form a light reddish brown complex. The absorbance of the complex is proportional to the ammonia nitrogen content to determine the ammonia nitrogen content in the water sample.
Product Features
The determination of ammonia nitrogen follows national standards, with accurate and effective data, HJ535-2009。
2. Imported solid-state cold light source with stable optical performance, no need for light source preheating, and a light source lifespan of up to 10 years.
3. Equipped with Glos water quality intelligent detection system, it can perform guided detection and batch detection of sewage samples.
4. Dissolve the sample without the need to switch to a white detection method, which is simple and efficient.
5.4.3 English high-definition color screen, flat UI design, convenient for users to operate quickly.
6. ABS material, high-strength, corrosion-resistant, and heat-resistant shell.
7. Check the automatic printing density value or select manual printing mode.
8. Equipped with pre made reagents, only the water sample for testing needs to be added to the test tube and then digested for testing.
Technical Parameter
PRODUCT MODEL |
TA800 |
Detection parameters |
Ammonia nitrogen rapid analyzer |
Measurement standards |
HJ535-2009 Determination of Ammonia Nitrogen in Water Quality Nash Reagent spectrophotometric method
|
measuring range |
0-100mg/L |
limit of detection |
0.05mg/L |
Dissolving temperature |
Not dissolving |
detection time |
30 water samples per minute |
Indication error |
≤ 5% or ± 0.1mg/L |
Instrument power supply |
AC(220V±5%),50Hz |
work environment |
5-40 ℃, ≤ 85% non condensing |
Instrument dimensions |
300mm×230mm×115mm |
Instrument weight |
About 2.8kg |
Display mode |
4.3-inch high-definition color LCD screen |
Colorimetric method |
Colorimetric tube (digestion colorimetric integrated) |
Expand functionality |
PC online |
Configuration List
1 host, 1 set of ammonia nitrogen reagent, 1 pipette, 1 test tube rack, 18 digestion colorimetric tubes, 4 dilution bottles, 1 piece of velvet cloth, 2 pairs of gloves, and 1 user manual.