VIP member
Three phase digital phase voltmeter
Function: Simultaneously measure three-phase AC voltage, current, phase, frequency, phase sequence, active power, power factor, etc. Voltage range: AC
Product details
FR2020 three-phase digital phase voltmeter, also known as multifunctional three-phase digital phase voltmeter, is a high-quality, multifunctional, high-precision, intelligent, portable handheld measuring instrument designed for on-site measurement of voltage, current, power, power factor, frequency, and phase. Widely used in energy metering, electricity inspection, power inspection, meter installation and relay protection, differential detection, start-up testing, industrial and mining enterprises, scientific research institutions and other departments. The instrument testing is characterized by precision, speed, simplicity, stability, and reliability.
The FR2020 three-phase digital phase volt ampere meter not only directly measures AC voltage and AC current values, phase and frequency between voltages, currents, and voltage and current, but also has other measurement and judgment functions. It can judge inductive current and capacitive circuits, check transformer wiring groups, and check whether the energy meter is wired correctly. It is an ideal instrument for grasping power usage and conducting secondary circuit inspections.
The FR2020 three-phase digital phase volt ampere meter consists of a main unit, current clamp, test line, and protective cover. It can store 500 sets of data and has a static data storage function. It has functions such as historical data reading, viewing, saving, reporting, and printing.
| Function | Measure three-phase AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, current vector sum, distinguish transformer wiring group, inductive and capacitive circuits, test secondary circuit and bus differential protection system, read out the phase relationship between CT of differential protection groups, check whether the wiring of the electricity meter is correct, and repair line equipment, etc | ||
| Power supply | 3.7V lithium rechargeable battery | ||
| Power consumption | Maximum 250mA | ||
| display mode | LCD color screen display, 72 × 55mm | ||
| Instrument size | Length, Width, and Thickness: 187 * 119 * 48mm | ||
| voltage range | AC 0.00V~600V | Resolution: 0.01V | Accuracy: ± 0.5% FS |
| current range | AC 0.0mA~20.0A | Resolution: 0.1mA | Accuracy: ± 0.5% FS |
| Phase range | 0.0°~360.0° | Resolution: 0.1 ° | Accuracy: ± 1 ° |
| Frequency range | 45.00Hz~65.00Hz | Resolution: 0.01Hz | Accuracy: ± 0.5Hz |
| Active power range | 0.0W~12kW | Resolution: 0.1W | Accuracy: ± (3% rdg+3dgt) |
| Reactive power range | 0.0W~12kVAR | Resolution: 0.1VAR | Accuracy: ± (3% rdg+3dgt) |
| Visual power range | 0.0W~12kVA | Resolution: 0.1VA | Accuracy: ± (3% rdg+3dgt) |
| Power factor range | -1~+1 | Resolution: 0.001 | Accuracy: ± 0.03 |
| Current vector and | 0mA~60.0A | ||
| Phase sequence | Positive phase: U1, U2, U3 or I1, I2, I3 The cursor flashes sequentially from left to right Reverse phase: U1, U2, U3 or I1, I2, I3 cursor flashes sequentially from right to left |
||
| Detection rate | About 2 seconds/time | ||
| data hold | During the test, press the HOLD key to hold the data, and the "HOLD" symbol will be displayed | ||
| Data Storage | 500 sets | ||
| Silicone protective cover | have | ||
| USBinterface | USB interface, data stored can be uploaded to the computer for easy analysis and management of data | ||
| Automatic shutdown | After about 15 minutes of startup, the instrument panel automatically shuts down to reduce battery consumption | ||
| Backlight function | Yes, suitable for use in dark places and at night | ||
| Voltage detection | When the battery voltage is below 3.2V, the low battery voltage symbol is displayed to remind timely charging | ||
| Instrument quality | Host: 380g (with battery) | ||
| Needle nosed current clamp: 180g × 3 | |||
| Test line: 190g | |||
| Length of voltage testing line | 1.5m | ||
| Current clamp wire length | 2m | ||
| Working temperature and humidity | -10℃~40℃; Below 80% Rh | ||
| Storage temperature and humidity | -10℃~60℃; Below 70% Rh | ||
| Input impedance | Test voltage input impedance: 1M Ω | ||
| Voltage resistance | The instrument circuit and the casing can withstand a sine wave AC voltage of 1000V/50Hz for 1 minute | ||
| Insulation | The distance between the instrument circuit and the casing is ≥ 100M Ω | ||
| Structure | Shell insulation | ||
| Suitable for safety regulations | IEC61010-1 CAT III 600V, IEC61010-031, IEC61326, Pollution Level 2 | ||
Online inquiry