Three box type cold and hot shock test chamber/high and low temperature shock test machine/wind type cold and hot shock test machine/water-cooled cold and hot shock test machine
1、 Product Introduction
This thermal shock test chamber is a three box type thermal shock test chamber used to test the degree to which material structures or composite materials can withstand continuous environments of extremely high and low temperatures in an instant, in order to test the chemical changes or physical damage caused by thermal expansion and contraction in the shortest possible time. The applicable objects include materials such as metal, plastic, rubber, electronics, etc., which can serve as a basis or reference for product improvement.
2、 Product Features
The three box equipment is divided into three parts: high temperature zone, low temperature zone, and testing zone. The test products are placed in the testing zone, and the high temperature zone or low temperature zone is balanced. The test products are dynamic.
Adopting a touch based graphical control interface, the operation is simple.
The impact method applies the air path switching method to import the temperature into the testing area for conducting cold and hot impact tests.
During high or low temperature impact, the maximum time can reach 999H and the maximum cycle period can reach 9999 times.
The system can be used as an automatic loop engine or a manual selective impact.
The cooling system adopts a binary freezing system, which has a fast cooling effect and is air-cooled.
Cannot test impact at room temperature
4、 Implement standards and test methods that meet the requirements
GJB150.5 Temperature Shock Test
GJB360.7 Temperature Shock Test
GB/2423.22 Temperature Shock Test
5、 Specification Table
| Model | HB-3D-80L | HB-3D-150L | HB-3D-225L | HB-3D-480L | ||
| Inner box dimensions | 50*40*40 | 60*50*50 | 70*60*60 | 80*80*75 | ||
| outer box dimensions | 160*180*155 | 185*190*185 | 110*149*113 | 102*164*124 | ||
| Operation mode | Fixed value operation/programmable operation (optional) | |||||
| system | PID Balanced Temperature Control System | |||||
| controller | Control type color LCD display human-machine interface controller | |||||
| Temperature stability | ≤±0.5℃ | |||||
| temperature range | Test tank | R: -40℃~+150℃ | L: -55℃~+150℃ | S: -65℃~+150℃ | ||
| High temperature tank | +60℃~+200℃ | +60℃~+200℃ | +60℃~+200℃ | |||
| Low temperature tank | -65℃~-40℃ | -70℃~-10℃ | -75℃~-10℃ | |||
| Impact return time | ≤5 mim | |||||
| Inner box material | Stainless steel mirror light plate (SUS 304 #) | |||||
| outer box material | Stainless steel matte line treatment (SUS 304 #) or spray painted paint (optional) | |||||
| Insulation material | Fine hard polyurethane foam and glass fiber cotton | |||||
| refrigeration system | Air cooling/water cooling (optional) | |||||
| Double stage: Fully enclosed or semi enclosed compressor, environmentally friendly refrigerant R404A+R23 | ||||||
| protective device | Non fuse switch, non fuse fuse, compressor overload protection switch, refrigerant high voltage protection switch, temperature air burn protection switch, under reverse phase protector, fault alarm system | |||||
| accessories | Two adjustable partitions at the bottom and top, with a test hole of Φ 50mm and one hole | |||||
| Sample weight (kg) | 5 | 5 | 10 | 15 | ||
| Weight (approximately kg) | 1000 | 1550 | 1680 | 1900 | ||
| power supply | 3Φ5W AC380V±10%50/6OHZ | |||||
| Note: When the ambient temperature is between 20 ℃ and 25 ℃ and the relative humidity is ≤ 85% R.H, the temperature and humidity distribution testing method is to measure the effective space at a distance of 1/6 from each side of the inner box. | ||||||
Characteristics and advantages of cold and hot shock test chamber:
1. The test shock recovery time is fast, which can be within 3-5 minutes, faster than general brand cold shock boxes.
2. The cold storage time is 20-30 minutes. Generally, the cold flushing box should last for more than 30 minutes, but ours can achieve 20-30 minutes.
3. Air cooling, abbreviated as air-cooled, is easy to install, has good cooling effect, is faster, and more efficient.
4. The controller operation adopts fuzzy algorithm and the latest technology for control. It adopts the cooling demand algorithm, which can reasonably and effectively utilize the cooling capacity, effectively reduce the consumption of cold and heat, and achieve stable control and energy-saving effects;
5. Imported 7 "TFT Korean ternary true color LCD touch screen, larger than other screens.
6. The controller interface is more convenient to operate, runs reliably, and is stable.
7. Control refrigeration system: Adopting static balance technology, namely the static balance method of "cooling process without heating" and "heating process without cooling", which is different from the traditional dynamic balance technology of "cold hot dynamic balance" for high-power refrigeration against high-power heating. When the compressor is turned on, the on-off refrigeration energy regulation technology is adopted, and the controller controls the cooling capacity by adjusting the refrigerant flow rate according to different temperature points (i.e. the "static balance" technology of cooling without heating and heating without cooling), so that the refrigeration and cooling losses in the laboratory maintain a static balance, and the temperature control accuracy can be achieved with less heating, so that the equipment always operates in a relatively low power consumption state. (Traditional production method: Constant customized cooling capacity is used to heat low cooling capacity while maintaining a constant temperature).
8. The refrigeration system compressor adopts imported French Taikang compressor, which has lower operating noise and superior performance.
9. With a sampling time of 60 seconds, it can ensure 120 days of real-time curve sampling and storage of historical data. The sampling rate can be set arbitrarily from 3 seconds to one hour.
10. Ultra long program capacity: 100 sets with 9999 cycles of memory.
11. Ultra long setting time: adjustable from 0 to 9999H59M.
12. Set the time for each program segment of 540 hours and 59 minutes.
13. Having USB The interface has direct copying and recording functions, including historical curves, historical data, etc., which can be directly copied to the computer for viewing, analysis, and storage.
14. Equipment RS-232C Communication interface, capable of bidirectional control of machine and computer hard disk storage data.
15. Optimization design combination of refrigeration system, stable and reliable
16. After sales guarantee, two-year warranty, lifetime service. If any problems occur during the use of the equipment, a response will be made within 8 hours of receiving notification, and maintenance engineers and technicians will be promptly dispatched to handle them.
For more details about the thermal shock testing machine, please call us for consultationRuan Sheng