Functional characteristics of pH unit
Circular pH sensitive membrane, fully sensing the pH value of the liquid.
Calibration from 1 to 3 points, automatically identifying USA or NIST standard buffer solutions.
Automatic temperature compensation ensures accurate measurement across the entire range.
The settings menu allows customization of pH buffer standards, number of calibration points, temperature units, etc.
Functional characteristics of EC unit
Platinum conductive electrode provides accurate and reliable measurement results.
Calibration from 1 to 3 points, automatic identification of conductivity standard solution.
Automatic temperature compensation, correcting conductivity measurements and converting readings to reference temperature.
The settings menu allows customization of the number of calibration points, TDS coefficient, temperature units, etc.
Functional characteristics of DO unit
Equipped with a polarographic electrode.
1 or 2-point calibration, using air saturated water or zero oxygen solution.
Salinity and atmospheric pressure compensation eliminate measurement errors.
Automatic temperature compensation ensures accurate measurement across the entire range.
The settings menu allows customization of the number of calibration points, concentration units, temperature units, etc.
General functional features
Automatic endpoint locking, retaining stable readings for easy browsing and recording.
Automatic power shutdown effectively saves battery energy consumption.
Reset function, automatically restore the instrument to factory default settings.
PHunit | ||
PH |
measuring range |
-1.00~15.00pH |
display resolution |
0.01pH |
|
measurement accuracy |
±0.01pH |
|
calibrated point |
1to3drop |
|
pHbuffering option |
USA (pH4.01/7.00/10.01), NIST (pH4.01/6.86/9.18) |
|
temperature |
measuring range |
0 ~60°C/32~140°F |
display resolution |
0.1°C/0.1°F |
|
measurement accuracy |
±1°C/±1.8°F |
|
offset calibration |
1drop,Measurement value ±10°C/°F |
|
other |
Temperature compensation range |
0~60°C/32~140°F,automatic |
Data locking |
Manual or automatic |
|
Automatic shutdown |
40After minutes of no button operation |
|
Power source |
LR44Type battery3joint |
|
ECunit | ||
conductivity |
measuring range |
0~20.00, 200.0, 2000µS/cm, 20.00mS/cm |
display resolution |
0.01, 0.1, 1,automatic |
|
measurement accuracy |
±1% F.S. |
|
calibrated point |
1~3drop |
|
Use calibration solution |
84µS, 1413µS, 12.88mS, |
|
TDS |
measuring range |
0~10.00, 100.0, 1000ppm, 20ppt |
display resolution |
0.01, 0.1,1,automatic |
|
measurement accuracy |
±1% F.S. |
|
TDSconversion coefficient |
0.1to1.0 (default0.5) |
|
salinity |
measuring range |
0~10.00ppt |
display resolution |
0.01ppt |
|
measurement accuracy |
±1% F.S. |
|
temperature |
measuring range |
0 ~60°C/32~140°F |
display resolution |
0.1°C/0.1°F |
|
measurement accuracy |
±1°C/±1.8°F |
|
offset calibration |
1drop,Measurement value ±10°C |
|
other |
Temperature compensation range |
0~100°C/32~212°F,automatic |
Temperature compensation coefficient |
2%/°C,, Linear |
|
reference temperature |
25°C |
|
Conductivity cell constant |
K=1 |
|
Data locking |
Manual or automatic |
|
Automatic shutdown |
40After minutes of no button operation |
|
Power source |
LR44Type battery3joint |
|
DOunit | ||
dissolved oxygen concentration |
measuring range |
0.0~20.0mg/L |
display resolution |
0.1mg/L |
|
measurement accuracy |
±0.5mg/L |
|
%saturation |
measuring range |
0.0~200.0% |
display resolution |
0.1% |
|
measurement accuracy |
±2.0% |
|
Other |
calibrated point |
1perhaps2drop |
Temperature compensation range |
0~40°C/32~104°F,automatic |
|
Range of atmospheric pressure compensation |
450~850mmHg,hand movement |
|
Salinity compensation range |
0~35g/L,hand movement |
|
Automatic shutdown |
40After minutes of no button operation |
|
Power source |
LR44Type battery3joint |
|