Thermo TRACE 1310 gas chromatograph
The Thermo Scientific TRACE 1310 gas chromatograph can help you improve productivity, accelerate response time, and reduce instrument holding costs. W
Product details

Thermo Scientific ™ TRACE ™ 1310 gas chromatograph

Thermo Scientific ™ TRACE ™ The 1310 gas chromatograph can help you improve productivity, accelerate response time, and reduce instrument holding costs. With its functional diversity and ultra-high GC and GC-MS performance, it is an ideal choice for large-scale production and QA/QC laboratories and research institutions. The system features a full touch screen design for instrument control, status monitoring, and method development on the instrument. With instant connection to the injection port and detector, you can replace modules, reconfigure different workflows, develop new methods, and save maintenance downtime in minutes.

Switch between injection port and detector within minutes

  • No special training or tools required, switch between injection port and detector within two minutes
  • Significantly reduces maintenance downtime, and samples can be restarted within minutes
  • Immediately switch to a different workflow or method

Improve productivity

  • Using robust injection port technology, analyzing dirty matrix samples requires almost no cleaning
  • With excellent detector sensitivity and micro volume technology, trace compounds can be analyzed with less injection volume and minimal pre concentration results.
  • Adopting optional blowback technology can protect system components and reduce operating time and maintenance
  • The use of low heat capacity injection ports and detectors, as well as rapid furnace chamber technology, can shorten the cycle time of sample operation
  • Use a range of sample processing options to automate the entire workflow (from pipetting to injection)
  • Using Thermo Scientific ™ Dionex ™ Chromeleon ™ Chromatography Data System (CDS) software simplifies and accelerates data analysis

Reduce the cost of instrument ownership

  • Reconfigure the module system to meet different requirements, or share injection ports and detectors among several GCs
  • Using tool free modules for easy maintenance to minimize downtime
  • Allow the use of standard consumables to reduce operating costs
  • Energy saving through low heat capacity and fast start
  • Minimize sample and solvent consumption with trace sample functionality

Instant connection between injection port and detector options

  • Helium saving module
  • Split/No Split (SSL); Reverse blowing function is also optional
  • Programmed temperature injection port (PTV); Reverse blowing function can also be selected
  • Flame ionization detector (FID)
  • Thermal conductivity detector (TCD)
  • Electron Capture Detector (ECD)
  • Nitrogen phosphorus detector (NPD)
  • Flame photometric detector (FPD)
  • Gas sampling valve

compatible

  • Thermo Scientific ™ TriPlus ™ RSH automatic sampler
  • Thermo Scientific ™ TriPlus 300 Headspace Automatic Sample Injector
  • Thermo Scientific ™ TriPlus 100 LS liquid automatic sampler
  • Thermo Scientific ™ AI/AS 1310 Automatic Sample Injector
  • Thermo Scientific ™ ISQ ™ Single quadrupole GC-MS
  • Thermo Scientific ™ ITQ ™ GC ion trap MS system (can be deleted, this product has been discontinued by the factory)
  • Thermo Scientific TSQ ™ 8000 triple quadrupole GC-MS/MS
  • Thermo Scientific ™ TSQ
  • Quantum XLS ™ Quantum XLS Ultra ™ Triple quadrupole GC-MS system
  • Thermo Scientific ™ DFS ™ High resolution GC-MS
  • Thermo Scientific ™ Delta V ™ Isotope ratio mass spectrometer
  • TRACE 1310 auxiliary furnace box

authentication

  • International Electrotechnical Commission (IEC): 6100-1:2001-61010-2-010:2003-61010-2-081:2001+A1: (2003)
  • CAN/CSA C22.2 No. 61010-1 and UL 61010-1
  • European Standard (EN): 6100-1:2001-61010-2-010:04-61010-2-081:2002
  • Electromagnetic compatibility (EMC) and radio frequency interference (RFI): CISPR 11/EN 55011:1 Group A and IEC/EN 61326-1:2006