VIP member
Testo 650 Reference and Water Activity Tester
Testo650 moisture activity meter testo650 standard humidity measuring instrument, with reading storage (up to 500000 readings), water activity probe,
Product details
Testo650 water activity meter
Testeo 650 standard humidity measuring instrument with reading storage (up to 500000 readings), water activity probe, battery, lithium battery, and factory report.
Testo650 can measure temperature CO2、 Speed, current, and voltage.
At the same time, the testo 650 can also be used to measure humidity and pressure.
The testo 650 can be upgraded to the multi-functional measuring instrument testo 400. Upgrade the functionality to make it always capable of performing your measurement tasks. The software upgrade function ensures that you always use the latest technology.
Practical functions:
Calculate all parameters in the Moller diagram:
Relative humidity% RH, dew point and pressure dew point (td, tpd)
Absolute humidity g/m3, dry wet bulb temperature
Humidity (g/kg), water vapor pressure (mbar/hPa)
Enthalpy kcal/kg
Water activity measurement with trend chart
atmospheric pressure
List of advantages:
Special advantage: Automatic correction of absolute pressure to ensure accurate measurement. Water activity measurement with trend display and automatic identification of balance.
Clear graphical display
3 user-defined function keys
Press the button to save or print
Power interface/fast charging
Integrated printer
Quick on-site printing
Data transfer with PC
Barcode pen
Easy to operate
2 external probe sockets, automatically identifying the connected probes
Technical Specifications
Optional probe
Attachment
Testeo 650 standard humidity measuring instrument with reading storage (up to 500000 readings), water activity probe, battery, lithium battery, and factory report.
Testo650 can measure temperature CO2、 Speed, current, and voltage.
At the same time, the testo 650 can also be used to measure humidity and pressure.
The testo 650 can be upgraded to the multi-functional measuring instrument testo 400. Upgrade the functionality to make it always capable of performing your measurement tasks. The software upgrade function ensures that you always use the latest technology.
Practical functions:
Calculate all parameters in the Moller diagram:
Relative humidity% RH, dew point and pressure dew point (td, tpd)
Absolute humidity g/m3, dry wet bulb temperature
Humidity (g/kg), water vapor pressure (mbar/hPa)
Enthalpy kcal/kg
Water activity measurement with trend chart
atmospheric pressure
List of advantages:
Special advantage: Automatic correction of absolute pressure to ensure accurate measurement. Water activity measurement with trend display and automatic identification of balance.
Clear graphical display
3 user-defined function keys
Press the button to save or print
Power interface/fast charging
Integrated printer
Quick on-site printing
Data transfer with PC
Barcode pen
Easy to operate
2 external probe sockets, automatically identifying the connected probes
| Brief description | Order Number | order |
| Testo 650 standard temperature and humidity meter, including battery, spare lithium battery, and calibration certificate | - |
Technical Specifications
| Storage temperature | -25.0...60.0°C |
| Operating temperature | 0.0...50.0°C |
| Battery Type | 1.5 V AA |
| battery life | 18.0 h |
| weight | 500.0g |
| Specifications (LxWxH) | 75.0 x 240.0 x 50.0 mm |
| Probe type (measured value) | range | ||
| CO2Probe (carbon dioxide) | 0.0...10000.0 ppm CO2 | ||
| Differential pressure>probe (pressure) | 0.0... inH2O | +/-0.0 inH2O ( ... inH2O) | |
| Pressure sensor 1 (Pressure) |
0.0... inH2O | ||
| Pressure sensor 1 (Pressure) |
0.0...25.0 psi | ||
| Pt100 (Temperature) |
-200.0...800.0 °C | precision | +/-1.0°C (-200.0...-100.0°C) +/-0.4°C (-99.9...-50.0°C) +/-0.1°C (-49.9...99.9°C) +/-0.4°C (100.0...199.9°C) +/-1.0°C (200.0...800.0°C) |
| resolution | +/-0.1°C (-200.0...-100.0°C) +/-0.01°C (-99.9...300.0°C) +/-0.1°C (300.1...800.0°C) |
||
| Pt100 (Temperature) |
-330.0...1500.0 °F | precision | +/-1.0°F (-330.0...-150.1°F) +/-0.4°F (-150.0...-58.1°F) +/-0.1°F (-58.0...212.0°F) +/-0.4°F (212.1...389.9°F) +/-1.0°F (390.0...1500.0°F) |
| resolution | +/-0.1°F (-330.0...-150.1 °F) +/-0.01°F (-150.0 ... 569.9 °F) +/-0.1°F (570.0 ... 1500.0 °F) |
||
| K型 (NiCr-Ni) (Temperature) |
-200.0 . .. 1370.0 °C | precision | +/-1.0°C (-200.0...-100.1°C) +/-0.4°C (-100.0...200.0°C) +/-1.0°C (200.1...1370.0°C) |
| resolution | +/-0.1°C (-200.0...1370.0°C) | ||
| K型 (NiCr-Ni) (Temperature) |
-330.0...2500.0 °F | precision | +/-1.0°F (-330.0...-150.1°F) +/-0.4°F (-150.0...389.9°F) +/-1.0°F (390.0...2500.0°F) |
| resolution | +/-0.1°F (-330.0...2500.0°F) | ||
| S-type (Pt10Rh Pt) (Temperature) |
0.0...1760.0 °C | precision | +/-1.0°C (0.0...1760.0°C) |
| resolution | +/-1.0°C (0.0...1760.0°C) | ||
| S-type (Pt10Rh Pt) (Temperature) |
32.0...3200.0 °F | precision | +/-1.0°F (32.0...3200.0°F) |
| resolution | +/-1.0°F (32.0...3200.0°F) | ||
| J-type (Fe CuNi) (Temperature) |
-200.0...1000.0 °C | precision | +/-1.0°C (-200.0...-150.1°C) +/-0.4°C (-150.0...150.0°C) +/-1.0°C (150.1...1000.0°C) |
| resolution | +/-0.1°C (-200.0...1000.0°C) | ||
| J-type (Fe CuNi) (Temperature) |
-330.0...1832.0 °F | precision | +/-1.0°F (-330.0...-240.1°F) +/-0.4°F (-240.0...299.9°F) +/-1.0°F (300.0...1832.0°F) |
| resolution | +/-0.1°F (-330.0...1832.0°F) | ||
| NTC (Temperature) |
-40.0...150.0 °C | precision | +/-0.4°C (-40.0...-10.1°C) +/-0.2°C (-10.0...50.0°C) +/-0.4°C (50.1...150.0°C) |
| resolution | +/-0.1°C (-40.0...150.0°C) | ||
| NTC (Temperature) |
-40.0...300.0 °F | precision | +/-0.4°F (-40.0...-14.1°F) +/-0.2°F (-14.0...121.9°F) +/-0.4°F (122.0...300.0°F) |
| resolution | +/-0.1°F (-40.0...300.0°F) | ||
| Testo humidity sensor, cap (humidity) | 0.0...100.0 %rF | resolution | +/-0.1%rF (0.0...100.0%rF) |
| Testo humidity sensor, cap (humidity) | 0.0...100.0 %RH | resolution | +/-0.1%RH (0.0...100.0%RH) |
| Differential pressure>probe (pressure) | 0.0... hPa | precision | +/-0.1% measurement value (... hPa) |
| Testo humidity sensor, cap (humidity) | 0.0...1.0 aW | ||
| Mechanical (rpm) | 20.0...20000.0 U/min | resolution | +/-1.0 U/min (20.0...20000.0 U/min) |
| Mechanical (rpm) | 20.0 . .. 20000.0 rpm | resolution | +/-1.0 rpm (20.0 ... 20000.0 rpm) |
| Current/voltage measurement (current (not used)) | 0.0...20.0 mA | precision | +/-0.04mA (0.0...20.0mA) |
| resolution | +/-0.01mA (0.0...20.0mA) | ||
| Current/voltage measurement (voltage AC) | 0.0...10.0 V | precision | +/-0.01V (0.0...10.0V) |
| resolution | +/-0.01V (0.0...10.0V) | ||
| CO2Probe (carbon dioxide) | 0.0...1.0 Vol. % CO2 | ||
| CO probe (carbon monoxide) | 0.0...500.0 ppm CO | precision | +/-5.0% measured value (0.0... 500.0ppm CO) |
| Pressure sensor 1 (Pressure) |
0.0...2000.0 hPa | precision | +/-0.2% measurement value (... hPa) |
Optional probe
| Brief description | product image | range | accuracy | Order number |
| Thermocouples, fiberglass heat pipes (5 pieces/pack) |
|
-200.0...400.0 °C | ||
| Pipeline probe with tear tape, suitable for a maximum diameter of 100mm |
|
-50…+150℃ | ||
| Precision air probe |
|
-100…+400℃ | ||
| Precision immersion probe, flexible, cable temperature resistance+300 ℃ |
|
-100…+265℃ | ||
| Immersion/insertion probe, high precision |
|
-100…+400℃ | ||
| Viscous thermocouple (2 pieces/pack) |
|
|||
| Immersion/insertion probe, high precision, with calibration certificate |
|
-40.0...300.0 °C |
||
| Surface probe, fast response, equipped with elastic thermocouple, with a range of up to+500 ℃ in a short time |
|
-200…+300℃ | ||
| Air probe, high precision, exposed sensor |
|
-40…+125℃ | ||
| Surface probe |
|
-200…+600℃ | ||
| Surface probe |
|
-50…+400℃ | ||
| Surface probe, bent 90 degrees, suitable for hard to reach areas |
|
-200…+600℃ | ||
| Immersion/insertion probe for gas and liquid measurement |
|
-200…+600℃ | ||
| Standard air probe |
|
-200…+600℃ | ||
| Immersion/insertion probe, sharpened measuring head, waterproof and anti baking |
|
-200…+400℃ | ||
| Surface probe, fast response, head bent 90 degrees, with elastic thermocouple |
|
-200…+300℃ | ||
| Immersion/insertion probe, fast response, used for high temperature measurement |
|
-200…+1100℃ | ||
| Immersion/insertion probe, fast response, used for measuring liquids |
|
-200…+600℃ | ||
| Immersion/insertion probe, fast response |
|
-200…+400℃ | ||
| Standard immersion/insertion probe |
|
-200…+600℃ | ||
| Standard immersion/insertion probe |
|
-200…+400℃ | ||
| Spare pipe clamp probe tip |
|
-60…+130℃ | ||
| Furnace probe with spare probe tip |
|
-200…+1250℃ | ||
| Plug in probe, 1030mm long, flexible, used for high temperature measurement, shell: nickel iron alloy |
|
-200…+1100℃ | ||
| Plug in probe, 550mm long, flexible, used for high temperature measurement, shell plated with nickel iron alloy 2.4816 |
|
-200…+1100℃ | ||
| Plug in probe, 1200mm long, flexible, used for high temperature measurement, housing: 1.4541 |
|
-330…+900℃ | ||
| Plug in probe, 750mm long, flexible, used for high temperature measurement, housing: stainless steel 1.4541 |
|
-200…+900℃ | ||
| Drum type probe, used for measuring rolling objects, with a maximum speed of 18-400m/min |
|
-50…+240℃ | ||
| Magnetic probe with an adhesion of approximately 10N |
|
-50…+400℃ | ||
| Magnetic probe with an adhesion of approximately 20N |
|
-50…+240℃ | ||
| Immersion/insertion probe, made of V4A stainless steel, waterproof and anti baking |
|
-200…+400℃ | ||
| Mini surface probe |
|
-200…+400℃ | ||
| Infrared surface probe, fast non-contact measurement, used for measuring rotating components |
|
-18…+260℃ | ||
| Surface probe with elastic thermocouple, measuring range up to+700 ℃ |
|
-200…+700℃ | ||
| Spherical temperature probe for measuring radiant heat |
|
0…+120℃ | ||
| Mechanical speed probe with plug |
|
|||
| High voltage probe, made of stainless steel, with a pressure resistance of 40 bar, without cable |
|
0.0...40.0 bar | ||
| High voltage probe, made of antifreeze stainless steel, with a pressure resistance of 435 PSI, without cable |
|
0.0...30.0 bar | ||
| Low voltage probe, made of antifreeze stainless steel, without cable |
|
-1.0...10.0 bar | ||
| Pressure probe, 800 |
|
0.0...800.0 inH2O 0.0...2000.0 hPa |
||
| Pressure probe, 40 |
|
0.0...40.0 inH2O 0.0...100.0 Pa |
||
| Pressure probe, 4 |
|
0.0...4.0 inH2O 0.0...10.0 hPa |
||
| Precision pressure probe, 0.4PSI, used for measuring differential pressure and wind speed (connected to pitot tube) |
|
0.0...40.0 inH2O 0.0...100.0 Pa |
||
| Precision pressure dew point probe, used for measurement in compressed air systems, with a test point of -40 ° C tpd |
|
0.0...100.0 %RH -60.0...50.0 °C tpd |
||
| Standard pressure dew point probe, used for measuring compressed air systems |
|
-30.0...50.0 °C tpd | ||
| Precision air temperature and humidity probe with certificate |
|
-20...+70℃, 0...+100%RH |
||
| Standard indoor air quality probe, temperature resistant to+70 ℃ |
|
-20...+70℃ 0...+100%RH |
||
| Pipeline temperature and humidity probe, can be connected to a telescopic handle |
|
-20...+70℃, 0...+100%RH |
||
| High humidity probe with sensor heating element |
|
0.0...100.0 %RH, -20.0 . .. 85.0 °C |
||
| Durable humidity probe, used for measuring balanced humidity or air outlet measurement |
|
-20...+120℃, 0...+100%RH |
||
| Material humidity cable |
|
|||
| Material humidity probe |
|
|||
| Sword shaped temperature/humidity probe |
|
-20...+70℃, 0...+100%RH |
||
| Water activity value set: pressure resistant precision humidity probe with certificate, measuring room, and 5 sampling containers |
|
0...1aW,-20...+70℃ 0...+100%RH |
||
| Flexible humidity probe (not maintaining its original shape), used for measuring hard to reach areas |
|
-20...+180℃, 0...+100%RH |
||
| Durable temperature/humidity probe, resistant to temperatures up to+180 ℃ |
|
-20...+180℃, 0...+100%RH |
||
| Flexible humidity probe |
|
-20...+140℃, 0...+100%RH |
||
| Flexible humidity probe, miniature measurement module, module cable length 1500mm, module size 50 × 19 × 7 |
|
-20...+125℃, 0...+100%RH |
Attachment
| Brief description | annotation | Order Number |
| Illumination software with interface | Used to display data in the form of data or tables | |
| Wind speed components, including measurement of air volume, comfort, etc | Upgrade through the repair center (upgrading testo 650 to testo 400) | |
| Refrigerant calculation upgrade component, including all commonly used refrigerant parameters | ||
| Memory upgrade component, capable of storing 500000 readings | Expand memory space (upgraded by repair center) | |
| Instrument sheath (anti impact), including hanging rope, magnetic bracket, and probe clamp | Prevent damage to instruments due to falling | |
| Plastic system box | Safely and orderly store instruments and their accessories | |
| Testeo 175/177 fastener specific lock | ||
| Printing labels (testo patent) for testo 575 printer (6 rolls/box) | ||
| Teflon protective cap, 5mm (5 pieces/pack) 16mm | Dustproof, suitable for measurement in high humidity and high wind speed environments | |
| DKD calibration certificate/humidity | Saturated salt solution, with a calibration point of 75.3% RH | |
| ISO calibration certificate/humidity | Saturated salt solution, with a calibration point of 75.3% RH | |
| DKD calibration certificate/humidity | Saturated salt solution: calibration point at 11.3% RH | |
| ISO calibration certificate/humidity | Saturated salt solution: calibration point at 11.3% RH | |
| Pressure probe adapter, 1/2 'external thread, 1/4' internal thread | ||
| Handle, used for plug-in measuring tips | ||
| Adapter, used to connect NiCr Ni thermocouple and probe | ||
| Wire mesh protective cap, 12mm | ||
| Metal protective cap for 12mm humidity probe | Used in situations where the wind speed is less than 10m/s | |
| Wire mesh filter, 21mm | Dust and damage prevention | |
| Teflon sintered cap, 21mm, used in corrosive environments | In high humidity and high wind speed situations | |
| Wire mesh protective cap for 21mm humidity probe | Used in situations where the wind speed is less than 10m/s | |
| Stainless steel sintered cap, 21mm, threaded to humidity probe | Protecting probes under heavy mechanical loads and high wind speeds | |
| Humidity probe calibration solution (33% RH) | ||
| Pressure probe magnetic bracket | Used for pressure probe 0638 1345/ .1445/..1545/. 1645mm adapter | |
| RS232 shielded cable (connecting instrument and PC) | ||
| Aluminum alloy system box | Used for safe and orderly storage of instruments and accessories | |
| Telescopic handle, 340-800mm long | ||
| Telescopic handle, with a maximum extension of 1m, used for probes with plugs | Cable: 2.5m long, PUR coated | |
| Connect probes for pressure probes 0638 1740, 0638 1840, | ||
| Extension cable, 5m long, used to connect cables with plugs and instruments | PUR coating | |
| Cable, 5m long, connecting probe with plug and instrument | PUR coating | |
| Rechargeable battery pack (4 × 2.4V/700mAh) | Used for fast charging | |
| Car power adapter | Used for charging instruments inside the car | |
| Power supply, 230 V/8 V/1 A, European plug | Used for powering instruments and charging rechargeable batteries | |
| Integrated printer, including 1 roll of thermal printing paper and battery | Quickly print on-site data | |
| Barcode pen | Quickly and accurately read on-site information | |
| Printer cover (dustproof, anti-collision) | Prevent instruments from being damaged due to falling | |
| Plastic instrument box | Used for safe and orderly storage of instruments and their accessories | |
| Cable, 1.5m long, connecting instrument and probe with plug | PUR coating | |
| DKD calibration certificate/temperature | Instruments equipped with air/immersion probes; The calibration points are -20 ° C; 0 ° C;+60 ° C; MI greater 0.2 K | |
| Thermal conductive silicone (14g), temperature resistant+260 ° C | Strengthen surface heat transfer | |
| DKD calibration certificate/temperature | Instruments equipped with air/immersion probes; The calibration point is 0 ° C;+100 ° C;+200 ° C | |
| Teflon sintered cap, 12mm, used in corrosive environments | High humidity and wind speed scenarios | |
| Calibration fluid kit, 11.3% RH/75.3% RH, including humidity probe adapter | Used for rapid calibration of humidity probes | |
| Surface humidity measurement adapter for 12mm humidity probe | ||
| Drilling protective cap, used for 12mm humidity probe | Measure the equilibrium humidity inside the borehole | |
| Stainless steel sintered cap, 12 mm, threaded connection to humidity probe | Used in high wind speed or dusty environments | |
| DKD calibration certificate/humidity | Electronic humidity meter; The calibration points are 11.3% RH and 75.3% RH at+25 ° C | |
| ISO calibration certificate/humidity | Electronic humidity meter; The calibration points are 11.3% RH and 75.3% RH at+25 ° C | |
| ISO calibration certificate/pressure | Absolute pressure; 5 calibration points distributed across the entire range | |
| Current/voltage cable (± 1 V, ± 10 V, 20 mA) | ||
| DKD calibration certificate/pressure | Absolute pressure; 11 calibration points distributed throughout the full range (0.1-0.6% of the full range) | |
| DKD calibration certificate/temperature | Contact surface temperature probe; The calibration points are+100 ° C;+200 ° C;+300 ° C | |
| ISO calibration certificate/temperature | Instruments equipped with air/surface probes; The calibration points are 0 ° C;+150 ° C;+300 ° C | |
| DKD calibration certificate/pressure | Differential pressure and positive pressure; 6 calibration points distributed across the full range (0.6% of the full range) | |
| DKD calibration certificate/temperature | Instruments equipped with air/surface probes; The calibration points are -20 ° C; 0 ° C;+60 ° C | |
| DKD calibration certificate/pressure | Differential pressure and positive pressure; 11 calibration points distributed across the entire range | |
| ISO calibration certificate/pressure box) | Differential pressure; 5 calibration points distributed across the entire range | |
| Immersion/insertion probe glass sleeve, corrosion-resistant | ||
| ISO calibration certificate/temperature | A thermometer equipped with a surface temperature probe; The calibration points are+60 ° C;+120 ° C;+180 ° C | |
| Backup lithium battery | Data will not be lost during battery replacement or charging | |
| ComSoft 3- Professional Edition Software | Including database, general analysis, and graphical functions | |
| Spare thermal printing paper (6 rolls/box) | ||
| Testo printer, including 1 roll of thermal printing paper and 4 AA batteries | On site printing of data | |
| Printer charger (including 4 standard rechargeable batteries) | Used for external charging of rechargeable batteries | |
| RS232 cable | Connecting instrument and PC, 1.8m long, used for data transmission |
Online inquiry