| brand | TES/Taiwan Taishi |
|---|
Taiwan Taishi TES-1306 digital thermometer
Technical parameters of Taiwan Taishi TES-1306 dual channel digital thermometer:
Taiwan TaishiTES-1306 digital thermometerElectrical specifications
Type J |
-200℃ to 760℃/ -328℉ to 1400℉ |
Type K |
-200℃ to 1370℃/ -328℉ to 2498℉ |
*Accuracy is calibrated in an environment with a temperature of 23 ± 5 ℃ and a relative humidity below 80% RH.
Taiwan Taishi TES-1306 digital thermometer temperature measurement range
Single thermocouple measurement
Gear position |
resolution |
range |
accuracy |
|
Type K |
Type J |
|||
℃ |
0.1℃ |
-200℃~0℃ |
-200℃~0℃ |
±(0.2%rdg+1℃) |
0℃~200℃ |
0℃~150℃ |
±(0.1%rdg+0.8℃) |
||
1℃ |
200℃~1370℃ |
150℃~760℃ |
±(0.2%rdg+2℃) |
|
℉ |
0.2℉ |
-328℉~32℉ |
-328℉~32℉ |
±(0.2%rdg+2℉) |
32℉~392℉ |
32℉~302℉ |
±(0.1%rdg+1.6℉) |
||
2℉ |
392℉~2498℉ |
302℉~1400℉ |
±(0.2%rdg+ 3℉) |
|
Accuracy under T1-T2 dual ended measurement mode: basic accuracy+0.2% reading.
Note: Accuracy error does not include the error of the temperature measuring rod. Please refer to the specifications of the temperature measuring rod.
General specifications of Taiwan Taishi TES-1306 dual channel digital thermometer
Exceeding the measurement range indication |
OL |
Polarity representation |
Automatic polarity '-' indicates |
Sampling rate |
0 ℃ to 40 ℃ (32 ℉ to 104 ℉) |
Load protection maximum input voltage |
DC 60 V,AC 24 V |
power supply |
Single 9V battery, 006P or IEC6F22 or NEDA1604 |
BATTERY LIFE |
About 100 hours |
Operating temperature and humidity |
0℃ to 40℃ (32℉ to 104℉ ), 10 - 80%RH |
Storage temperature and humidity |
-10℃ to 60℃ (14℉ to 140℉ ), 10 - 80%RH |
size |
135mm (length) x 72mm (width) x 31mm (height) |
weight |
Approximately 235 grams |
attachment |
User manual, battery, protective cover, temperature measuring rod (TP-K01) |