VIP member
Taishida EF customized biosafety cabinet
Taishida EF customized biosafety cabinet is suitable for handling biological research (such as bacteria, viruses, etc.) and allergen (biosafety levels
Product details
Taishida EF customized biosafety cabinet
Explanation:
Taishida EF customized biosafety cabinet is suitable for handling biological research (such as bacteria, viruses, etc.) and allergen (biosafety levels 1, 2, 3) samples.
Taishida EF Clean Series Secondary Biosafety Cabinet provides high-level protection for operators, samples, and the environment. Minimize the harm in operations involving biological hazard levels 1, 2, 3.
This series of customized safety cabinets is designed based on high quality, high-level biological safety, high flexibility, ergonomic and practical considerations.
Safety standards:
The EF series biosafety cabinets are designed and manufactured according to international biosafety standards EN12469 (Level 2), NSF49 (Level 2 A2), and JIS K 3800 (Level 2 A2). The EF series safety cabinet has passed independent testing and certification by T ü V Nord, ensuring that the biosafety cabinet complies with the EN12469 standard. The work area is classified according to ISO 14644-1 (Class 5) and GMP Annex 1 (Class A) standards.
Basic principle:
The EF cabinet achieves protection for operators through incoming airflow, protects products through HEPA high-efficiency filters in the work area (30% exhaust, 70% recycling), and protects the environment through the external exhaust flow of HEPA high-efficiency filters.
Description:
This safety cabinet can meet some special applications of customers, such as hybrid weighing systems, microscopes, etc;
This cabinet has been designed for fixed solutions, such as isolation in the pharmaceutical, biotechnology, and food industries.
Standard settings
The outer panel is made of dried painted steel plate
Stainless steel inner liner
A stainless steel workbench
The safety cabinet has passed independent testing and certification by T ü V Nord, ensuring that the biosafety cabinet complies with EN12469 standards;
Exceeding the EN12469 standard, its multi shell structure ensures that all contaminated areas are under negative pressure or surrounded by negative pressure;
The workbench has V-shaped ventilation openings that provide advanced safety, preventing airflow from blocking and contaminating the operator's cuffs;
Filter blockage monitoring, with prompts displayed in the control panel;
● Automatic compensation for filter blockage: The microprocessor will automatically increase the fan speed to compensate for filter blockage;
All components (filters, etc.) can be easily accessed from the front of the safety cabinet;
The work area is classified according to ISO 1464401 (Level 5) and GMP Appendix 1 (Level A);
The hinged sliding front window can be fully opened and closed in a sliding manner. After the front window is opened, thorough cleaning and placement of large-sized products can be completed outside the operating area;
The front window is made of safety laminated glass (8mm, 2 layers), with pre designed working and switch positions;
Ergonomic epoxy aluminum arm support makes the operator more comfortable;
The fluorescent lamp is located outside the work area. Will not disrupt the sinking airflow, will not form shadows, and will not cause blockages during cleaning;
Ergonomic foot pads integrated into optional brackets;
Each workbench is equipped with a seamless stainless steel standard configuration. This design is easy to clean and can collect an additional 2-3 liters of spilled liquid;
The workspace is designed as a standard configuration with a stainless steel rounded corner, making it easy to clean;
● Easy to connect to the external pipeline: The external filter is located on the right-hand side of the top of the safety cabinet (except for EF/B 6: the external filter is located in the center);
Clever design makes the airflow sensor easier to replace;
The user-friendly control panel displays all relevant functions and alarms.
·Green light indicates that the safety cabinet is in working mode
·Red display with sound and light alarm
Sinking airflow (high/low)
·Inflow airflow (high/low)
·Front window (non working position)
·Filter blockage
·Working mode switch*
·Standby mode switch
·UV lamp switch*
·Fluorescent lamp switch
·Electric socket switch*
·Gas valve switch
·Five languages: English, Spanish, French, German, and Dutch
·Real time clock
·Total timing for the use of fans, fluorescent lamps, and ultraviolet lamps
·PIN code prevention for unauthorized use
·RS232 and RS485 connectors
·Non voltage contact alarm management system
·Non voltage contact external system control switches such as additional exhaust fans
·Disinfection control preparation
*At the same time, clock switches or timing can be managed through programming.
Gas valve safety control: The gas valve can only be opened when the safety cabinet is in safe working mode. If the safety cabinet is in a shutdown or alarm state, the gas valve will automatically close;
UV lamp safety control: When turning on the UV lamp, the fluorescent lamp must be turned off;
● Two redundant microprocessors (with automatic fault prevention devices);
Optional: The exhaust flow rate can be adjusted according to GMP Annex 1 and PIC's standards;
● Optional: Pre filter and collection tray. It can prevent fine dust, dirt, and particles from entering the interior of the safety cabinet, fully ensuring the longest service life and purification effect of the HEPA filter;
Standard sizes 4, 5, and 6 feet wide (120, 150, and 180cm).
Accessories and Options:
The optional components and accessories make this series of cabinets suitable for various applications. Our technical department's flexibility and specialized expertise enable this series of cabinets to meet specific customer requirements.
Options:
1. Electric socket
2. Faucet (natural gas, vacuum, oxygen, nitrogen, etc.)
3. UV lamp
4. Purification connection equipment
5. Outward conversion equipment
6. Dual external HEPA filter
7. Data connection box (USB, etc.)
8. Built in monitor
9 FAT / SAT / IQ / OQ
Attachment:
1. Bracket (fixed bracket, adjustable electrical bracket, GMP compatible bracket)
2. Independent workbench
3. Purification equipment
4. External casing
5. Check valve
Online inquiry