The main purpose of the T35 axial flow fan is to replace the 30K4 type, which was introduced in the 1950s from the former Soviet Union and analyzed and compared with similar foreign products. Through model experiments, the fan airfoil was determined, and a cylindrical hub structure was adopted. The electric motor was modified to reduce flow losses structurally, thus increasing the fan efficiency to 77% based on the circular area and 89.58% based on the outlet ring area. The noise to A-level was reduced by 3.6dB, and the strength at the blade root was enhanced to avoid blade fracture.

The BT35 explosion-proof axial flow fan, due to its adoption of explosion-proof measures and the use of explosion-proof motors, can be used as a general explosion-proof ventilation equipment in non corrosive places containing flammable and explosive gases. The T35 BT35 axial flow fan can be used for ventilation and heat dissipation in general factories, warehouses, offices, and residential areas. If the casing is removed, it can be used as a free fan. It can also be installed in series at intervals in longer exhaust pipes to increase the air pressure in the pipes.

form

This series of products is divided into 13 machine numbers according to different impeller diameters, arranged in sequence as No.2.8, 3.15, 3.55, 4, 4.5, 5, 5.6, 6.3, 7.1, 8, 9, 10, 11.2, etc. Each machine number can be installed at 5 angles, including 15 °, 20 °, 25 °, 30 °, and 35 °.

This series of products adopts a direct connection structure where the impeller is directly mounted on the motor shaft. Under the condition that the circumferential speed of the impeller does not exceed 60m/s, three speeds are used: 2900r/min, 1450r/min, and 960r/min. The impeller rotates counterclockwise when facing the inlet direction, and the inlet direction is at the end of the impeller.

The gas passing through the T35 BT35 fan should be non corrosive and free of significant dust, and its temperature should not exceed 40 ℃. BFT35 fan can pass various corrosive gases (without any dust), and its temperature should not exceed 60 ℃.

All ventilation fans undergo operation tests before leaving the factory to ensure smooth operation.

structural style

BFT35 fan is mainly composed of impeller, casing, collector, etc., all of which are made of fiberglass. The bracket is made of profiles and connected to the air duct.

The T35 BT35 fan is mainly composed of impellers, casings, and collectors.

The impeller is composed of blades and a hub, both made of thin steel plates and welded to the hub at selected installation angles.

The casing is composed of an air duct and a bracket, both made of thin steel plates and profiles. The air duct is cylindrical with a certain gap between it and the impeller (BT35 fan air duct is internally riveted with aluminum lining for explosion prevention).

The collector section consists of a collector flange and a collector. The air collector is a curved streamline that reduces the loss of airflow at the inlet and is made of thin steel plate.

Performance and Selection

The performance of the fan in the performance table refers to the air performance under standard conditions (temperature 20 ℃, relative humidity 50%, atmospheric pressure 101.3 × 103Pa, gas density 1.2kg/m ³). If the ventilation fan operates in non-standard conditions, its performance needs to be converted. To change its fan speed, its performance can be converted according to relevant formulas.

T35, BFT35 Axial Flow Fan Performance Table

Machine number

Speed r/min

Air volume m ³/h

Total pressure Pa

Motor power Kw

2.8

2900

1224

128

0.12

1742-2560

141-143

0.180

2495

165

0.350

2778

186

0.370

1450

613-1133

32-35.7

0.025

1251-1392

41.2-46.6

0.040

3.15

2900

1944

170.1

0.180

2681

186.6

0.250

3418

189.2

0.370

3853-4155

217.7-247.0

0.550

1450

972

42.5

0.025

1340-1709

46.6-47.2

0.040

1877

54.9

0.060

2078

61.7

0.090

3.55

2900

2783

216.1

0.370

3839

237

0.550

4895-5375

240.3-279

0.750

5951

313.6

1.1

1450

1394

54

0.040

1923

59.2

0.060

2452-2692

60.2-69.7

0.090

2981

78.4

0.120

4

2900

3980

274.3

0.75

5489-6999

300.9-305.1

1.1

7685

354

1.5

8500

398.2

2.2

1450

1993

68.6

0.090

2749

75.2

0.120

3505-3849

76.2-88.5

0.180

4261

99.5

0.250

4.5

1450

2838

0.67

0.120

3914

0.71

0.180

4991

0.72

0.250

5480-6067

0.67-0.71

0.370

5

1450

4289

112.6

0.250

5763

124.8

0.370

7273-7907

129.6-145.6

0.550

8712

164.6

0.750

960

2839-5768

49.1-71.8

0.370

5.6

1450

6025

140.9

0.370

8097

156.1

0.550

10168

162.6

0.750

11110-12239

182.1-206

1.1

960

3989-8103

61.8-90.3

0.370

6.3

1450

8579

178.3

0.750

11528

197.6

1.1

14477-15817

205.8-230.5

1.5

17426

260.7

2.2

960

5680-9585

78.2-90.2

0.370

10472-11534

101.0-114.3

0.750

7.1

1450

12280

226.5

1.5

16501

250.9

2.2

20722-22641

261.4-292.7

3

24944

331.1

4

960

8130-17320

99.3-114.6

0.75

14990-16514

128.4-145.2

1.1

8

1450

17567

287.6

3

23605

318.6

4

29644-32389

331.8-371.6

5.5

35682

420.3

7.5

960

11630

126.1

0.75

15628-19626

139.6-131.1

1.1

21444

162.9

1.5

23624

184.2

2.2

9

960

16560

159.5

1.5

22252-27944

176.7-184.1

2.2

30532

206.2

3

33937

233.2

4

10

960

22716

197

2.2

30524

218.2

3

38333

227.3

4

41882-46141

254.5-287.9

7.5

11.2

960

31914

247

4

42844

273.7

5.5

53855

285.1

7.5

58841-64825

319.3-361.1

11

Performance Table of BT35 Explosion proof Axial Flow Fan

Machine number

Speed r/min

Air volume m ³/h

Total pressure Pa

Motor power Kw

2.8

2900

1102-2246

122-157

0.180

2500

177

0.25

1450

552-1253

30-44

0.120

3.15

2900

1750

162

0.180

2413

177

0.250

3076-3378

180-207

0.370

3739

235

0.550

1450

875-1870

40-59

0.120

3.55

2900

2505

205

0.370

3455-4406

225-237

0.550

4838

265

0.750

5356

298

1.100

1450

1255-2683

51-75

0.120

4

2900

3582

261

0.550

4935-6916

286-336

1.100

7657

378

1.500

1450

1794-3155

65-72

0.120

3464

84

0.180

3835

95

0.250

4.5

1450

2554

82

0.120

3523

90

0.180

4492

92

0.250

4932-5460

106-120

0.370

5

1450

3860

107

0.250

5187-6513

119-123

0.370

7136

138

0.550

7841

156

0.750


2555-5191

47-68

0.370

5.6

1450

5423

134

0.370

7287

146

0.550

9151

154

0.750

9999-11015

173-196

1.1

960

3590-7293

59-86

0.370

6.3

1450

7721

169

0.750

10375

188

1.1

13029-14235

196-219

1.5

15683

248

2.2

960

5112-8627

74-86

0.370

9425-10384

96-109

0.750

7.1

1450

11052

215

1.5

14851-18650

238-248

2.2

20377

278

3

22450

315

4

960

7317-13491

94-122

0.750

14863

138

1.1

8

1450

15870

273

2.2

21245-26680

303-315

4

29150

353

5.5

32114

399

7.5

960

10467

120

0.750

14065

133

1.1

17663-19299

125-155

1.5

21262

175

2.2

9

960

14904

152

1.5

20027-25150

169-175

2.2

27479

196

3

30273

222

4

10

960

20444

187

2.2

27472

207

3

34500-37694

216-242

4

41527

274

7.5

11

960

28723

235

4

38596

260

5.5

48470-52957

271-303

7.5

58343

341

11


The above is a detailed introduction about the T35 axial flow fan manufacturer, T35 axial flow fan price, T35 axial flow fan supply, T35 axial flow fan manufacturer, and T35 axial flow fan sales
Regional products:
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!