Guangzhou Beize Instrument Technology Co., Ltd
Home>Products>T-2 oxygen sensor T-2, oxygen cell T-2
T-2 oxygen sensor T-2, oxygen cell T-2
American AMI Oxygen Sensor: Oxygen Sensor T-2, Oxygen Cell T-2, Fuel Cell T-2 Oxygen Sensor T-4, Oxygen Cell T-4, Fuel Cell T-4 Oxygen Sensor P-2, Oxy
Product details

American AMI oxygen sensor

Oxygen sensor T-2, oxygen cell T-2Fuel Cell T-2

Oxygen sensor T-4Oxygen cell T-4Fuel cell T-4

Oxygen SensorP-2. Oxygen batteryP-2. Fuel cellP-2

Oxygen SensorP-3Oxygen batteriesP-3Fuel cellP-3

Oxygen SensorP-4Oxygen batteriesP-4Fuel cellP-4

Oxygen SensorP-5Oxygen batteriesP-5Fuel cellP-5

American AMI oxygen sensorT-seriesIncluding 2 highly specific oxygen sensorsT-2 andOxygen SensorT-4Provide high levels of accuracy, reliability, and linearity throughout the entire measurement range. In fact, we are a company in the world that produces PPM electrochemical oxygen sensors that can resist trace amounts of H2S. Our BULLET SENSOR TECHNOLOGY ™ sendT-4oxygenSensors can provide error free performance even when exposed to H. H2S levels can reach up to 500ppm. In addition, all of ourT-seriesSensors can withstand environments with 100% CO2. AMI ensures the resistance of our sensors to these problematic gases within their guaranteed product lifespan.

Technical parameters:

T-series

P series

AMI model

T-2

T-4

P-2

P-3

P-4

P-5

range

0-10,000ppm

0-10,000ppm

0-50%

0-25%

0-100%

0-25%

range

0-5ppm

0-5ppm

0-1000ppm

0-1000ppm

0-1%

0-1000ppm

detection limit

0.05ppm

0.05ppm

10ppm

100ppm

1000ppm

100ppm

90% full range response time (increased oxygen content)

8 seconds

8 seconds

8 seconds

30 seconds

30 seconds

30 seconds

1 minute of air exposure time is less than 10ppm

<15 minutes at 70 ° F

<15 minutes at 70 ° F

Not Applicable

Not Applicable

Not Applicable

Not Applicable

life expectancy

12 to 24 months in oxygen below 100ppm

12 to 24 months in oxygen below 100ppm

12-15 months 20.9% 0xygen

9-12 months 20.9% 0xygen

18 months 20.9% 0xygen

9-12 months 20.9% 0xygen

Warranty FOB Costa Mesa, California

6 months

6 months

6 months

6 months

6 months

6 months

application

The H2S content in PPM oxygen is 10ppm. Almost all background gases (including carbon dioxide) have a content ranging from zero to 100%.

The H2S content in PPM oxygen is as high as 500ppm. The content of almost all background gases (including carbon dioxide) ranges from zero to 100%.

Percentage of oxygen in inert or reducing background gas

Percentage of oxygen in background gas containing CO2

Percentage of oxygen in inert background gas

The oxygen content in the background gas containing CO2 is 500ppm H2S

Attention:
*Indicating an air calibration range of 0-25%
**Indicates less than 25% oxygen
T-2oxygenSensors and T-4oxygenThe oxygen range of the sensor during the warranty period is 0-10000 ppm. Therefore, they can easily perform short-term air exposure (containing 20.9% oxygen) for calibration!

Oxygen sensor T-2, oxygen cell T-2

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!