Technical parameters of V-cone flowmeter for steam pipeline:
1. Accuracy level: 0.5 level (differential pressure flow transmitter accuracy should be higher than 0.2 level, including 0.2 level), (β: 0.45-0.85, when β<0.55 and range ratio 4:1, accuracy level: ≤ 0.30)
2. Repeatability: 0.11%
3. Work pressure: 0-40MPa (with multiple pressure levels to choose from)
4. Working temperature: -40~851 ° C · Environmental temperature: -42~65 ° C
5. Installation requirements for straight pipe section: front 0-3D straight pipe, rear 0-1D straight pipe section. Range width ratio: usually 10:1, selecting appropriate parameters can achieve 50:1
6. Small pressure loss: For the same β value, the pressure loss is 1/3 to 1/5 of the orifice plate
7. Caliber ranging from DN25 to DN2000
Technical characteristics of V-cone flowmeter for steam pipeline:
1. Low installation requirements: front 0-3D straight pipe, rear 0-1D straight pipe section;
2. Range width ratio: usually 10:1, selecting appropriate parameters can achieve a higher ratio of 50:1;
3. Small pressure loss: For the same β value, the pressure loss is 1/3 to 1/5 of the orifice plate;
4. Wear resistance: After throttling the streamlined cone, a vacuum layer effect is generated on the surface of the cone, making it less prone to wear; 5. No blockage, no adhesion: The conical thorough blowing design avoids the retention of residues, condensates, or particles in the fluid;
6. Good long-term stability: The β value can remain unchanged for a long time and ensure long-term measurement;
7. High precision: 0.52 level;
8. Good repeatability: better than 0.122%;
9. Signal stability: 'Signal fluctuation' is 1/10 of the orifice plate;
10. Wide range of beta values: The unique geometric shape of the V-cone flow sensor allows for a wide range of beta values;
11. Wide caliber range: DN25 to DN2000;
12. Measurable high temperature and high pressure media: working temperature is higher at 850 ℃, with a higher pressure of 40MPa;
13. Measurable dirty media (coke oven gas, blast furnace gas, raw oil, residual oil, etc.);
14. Measurable gas-liquid two-phase media (moisture, condensate, etc.);
Technical parameters of V-cone flowmeter for steam pipeline:
1. Accuracy level: 0.5 level (differential pressure flow transmitter accuracy should be higher than 0.2 level, including 0.2 level), (β: 0.45-0.85, when β<0.55 and range ratio 4:1, accuracy level: ≤ 0.30)
2. Repeatability: 0.11%
3. Work pressure: 0-40MPa (with multiple pressure levels to choose from)
4. Working temperature: -40~851 ° C · Environmental temperature: -42~65 ° C
5. Installation requirements for straight pipe section: front 0-3D straight pipe, rear 0-1D straight pipe section. Range width ratio: usually 10:1, selecting appropriate parameters can achieve 50:1
6. Small pressure loss: For the same β value, the pressure loss is 1/3 to 1/5 of the orifice plate
7. Caliber ranging from DN25 to DN2000