Shanghai Binrui Testing Technology Service Co., Ltd
Home>Products>Standard rigid pipeline mirror swinging prism pipeline mirror
Standard rigid pipeline mirror swinging prism pipeline mirror
The direct view rigid pipeline mirror can be adjusted according to the tilt of the field of view from forward to backward, and its field of view angle
Product details

Standard rigid pipeline mirror swinging prism pipeline mirror

The direct view rigid pipeline endoscope can be adjusted according to the viewing angle from forward tilt to backward observation, with a viewing angle ranging from 120 ° to 140 °

A single rigid pipeline mirror cannot meet the needs of large-scale observation. The standard rigid pipeline mirror has a fixed observation direction and field of view, suitable for detecting a single area. If equipped with multifunctional accessories, it can detect a larger range of areas.

The characteristic of the rotating prism pipeline mirror is the adjustable prism at the target end of the instrument. The operator can control the observation direction from a distance using this prism, with an observation angle of 45 ° to 115 ° in front, which is equivalent to "scanning" the area. Combined with the 50 ° standard field of view of the instrument, its observation radius can reach 120 °. In addition, the optical waveguide fiber at the target end can provide divergent illumination light from different light outlets covering the entire observation area.

The design of the rotating prism embodies all the optical technology innovations accumulated by Olympus in the development of standard rigid pipeline mirrors.


- Characteristics

-Advanced optical system

Olympus has a reputation for optical innovation, and standard pipeline mirrors are no exception. Each diameter of the pipeline mirror is tailored according to its unique lens technology, optimizing the available space. Multi lens coating is used to reduce internal reflection and enhance the brightness and contrast of images.


-Rotating prism mechanism

The observation direction of the observation instrument can be continuously adjusted. The observation angle is 45 ° to 115 ° in front, combined with the field of view, and the observation arc can reach 120 ° (20 ° to 140 °).


-Track scanning

When the pipeline mirror is fixed or connected to CCTV (Pipeline Camera Inspection), this function can rotate the inserted pipeline 370 degrees without affecting the controller housing or accessories attached to the eyepiece.


-Advanced stainless steel products inserted into pipes

Durable, corrosion-resistant, and fluid resistant, equipped with an outer protective sheath.


-Laser welding end

Ensure safe and fault free detection to reduce the possibility of end drops.


-Ergonomic design of control housing

Comfort and practicality are the design concepts of Olympus for the casing of pipeline mirrors. Series 5 has made further breakthroughs in design, achieving true one handed operation.


-Color code identification ring

The eyepiece ring is engraved with the serial number and model reference. At the same time, use color codes to indicate the observation direction of the pipeline mirror.


-Lens to fiber ratio

A large lens can provide enough light to clear the surrounding image, but the overall effect actually depends more on the optical transmission performance of the instrument. Series 5 products effectively combine high-precision lenses and optical fibers to achieve excellent image illumination.



technical specifications

Performance and specifications of rotating prism tube mirror

product code

outside diameter

Length

View direction

field of view

depth of field

R060-023-045SW115-50

φ6.1mm

23cm

45 to 115°

50°

5 mm to infinity

R060-031-045SW115-50

31cm

R060-046-045SW115-50

46cm

R060-061-045SW115-50

61cm

R060-077-045SW115-50

77cm

R080-023-045SW115-50

φ8.1mm

23cm

R080-024-045SW115-20

24cm

20°

30 mm to infinity

R080-033-045SW115-50

33cm

50°

5 mm to infinity

R080-043-045SW115-50

43cm

R080-044-045SW115-20

44cm

20°

30 mm to infinity

R080-053-045SW115-50

53cm

50°

5 mm to infinity

R080-063-045SW115-50

63cm

R080-064-045SW115-20

64cm

20°

30 mm to infinity

R080-083-045SW115-50

83cm

50°

5 mm to infinity

R080-103-045SW115-50

103cm


The working environment for standard rigid endoscopes

Operating temperature

Insert tube

In the air:- 20 ~ 150 ℃

Underwater: 10 ~ 30 ℃

Insert components outside the tube

In the air:- 20 ~ 50 ℃

Atmospheric pressure during homework

Insert tube

In the air: 700-1700 hPa

Underwater: maximum 1700 hPa

Insert components outside the tube

In the air: 710-1060 hPa

Liquid resistance

Even if it comes into contact with engine oil, light oil, or a 5% salt solution, there will be no problem

Waterproof characteristics

Insert tube

Waterproof: Can work underwater

Insert components outside the tube

Prevent dripping and leakage

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!