Four line pure text display, menu guided on-site operation, quick and simple instrument debugging, available in 7 languages
-
On site envelope display, complete simple instrument fault diagnosis
-
Linearization function (up to 32 points) can convert measurement values into any unit of length, volume, or flow rateSpot E H Ultrasonic Level Gauge FMU30-AAHEAAGGF
-
Non contact measurement, minimizing maintenance services to the greatest extent possible
-
Threads G1 half or 1 half NPT or above can be installed
-
Built in temperature sensor, automatically corrects the speed of sound affected by temperature
-
-
application area
Suitable for continuous and non-contact level measurement of liquids, slurries, sludge, and solid blocks; System integration: 4...20mA; Maximum measurement range: 1/2 Sensor: Liquid: 5m (16ft); Solid: 2m (6.6ft); 2 'Sensor: Liquid 8m, Solid 3.5m (11 ft)Spot E H Ultrasonic Level Gauge FMU30-AAHEAAGGF
Features and specifications
-
measuring principle
ultrasonic
-
Features/Applications
Compact ultrasonic transmitter
-
Power/Communication
2-wire
-
ambient temperature
-20 °C... 60 °C
(-4 °F... 140 °F) -
process temperature
-20 °C... 60 °C
(-4 °F... 140 °F) -
Process pressure (absolute pressure)/maximum overpressure limit value
0.7 bar... 3 bar abs
(10 psi ...44 psi) -
Main liquid receiving components
PP/EPDM
-
Process connection
G / NPT 1 1/2'
G / NPT 2' -
Blind spot distance
Sensor 1 1/2': 0.25 m,
Sensor 2': 0.35 m -
communication
4...20 mA
-
Certificates and certifications
ATEX, CSA C/US, IEC Ex, NEPSI
-
option
Accessory Enclosed:
UNI flange 2'... 4' -
Application Restrictions
Take notice of range diagram