Features and advantages
+Compliant with ANSI and IEC standards
+You can choose between level 1 or level 2 precision universal models
+Can run two 'virtual' sound level meters simultaneously
+Can measure both A-weighted and C-weighted simultaneously
+Programmable and triggered by sound level to start and stop
+A, C, and Z (flat) frequency weighting
+Fast, slow, and IEC pulse response time
+Optional threshold of 10 dB -140 dB
+3, 4, 5, 6dB exchange rate
+Luminous keyboard and backlit display
+SD memory card slot
+USB communication interface and RS-232 serial port output
+Adjustable display in multiple languages
+Record historical data with storage intervals ranging from 1 second to 60 minutes*
+Background clearing function
+Noise dose calculation/dosimetry function
*Only DL series
application
+Industrial noise assessment
+Environmental noise assessment
+Enforcement of Noise Regulations and Legal Measurement
+General noise and spectrum analysis
+Vehicle noise assessment
+Architectural Acoustics
+Mobile device evaluation
Sound pressure level display
Quasi analog and digital display
Simulated Display View
Display the current sound pressure level (SPL) based on the selected response time and filter weighting. The amplitude of measuring sound pressure level will be displayed simultaneously in the form of horizontal bars and numbers, with the numbers displayed below the bars. If the measured value is higher than the minimum value of the selected measurement range, a bar will appear.
1/1octave
Bar chart display
Bandwidth Bar Chart View
Display the 1/1 octave band spectrum analysis measurement values of the frequency band and bandwidth values of instrument 1 and 2 filters. The screen displays 13 columnar bars, including data within a specific bandwidth of 11 1/1 octave band filters and bandwidth sound pressure level data of 2 measurement channels. If the measured value is higher than the minimum value of the selected measurement range, a bar will appear.
1/3octave
Bar chart display
Bandwidth Bar Chart View
Display the 1/3 octave band spectrum analysis measurement values of the frequency band and bandwidth values of instrument 1 and 2 filters. The screen displays 35 columnar bars, including data from 33 1/3 octave band filters within a specific bandwidth and bandwidth sound pressure level data from 2 measurement channels. If the measured value is higher than the minimum value of the selected measurement range, a bar will appear.
DMS detection management software
Specially designed for dose determination, sound level measurement, thermal index assessment, and environmental monitoring, this advanced software can assist professionals in safety, health, and occupational health
personage:
+Configure instruments and save instrument preset values
+Retrieve, download, share, and save instrument data
+Generate charts, tables, and reports to visually illustrate your test results
+Export and share record results
Optional features andScalability
Quest SoundProOutdoor detection system(SP-OMS)
The SoundPro outdoor detection system helps protect instruments from wind, rain, snow, chemicals, particulate matter, animals, damage, and theft, and can also extend battery life for up to a week of continuous monitoring (with the option of a second battery for two weeks). In addition to storing instruments and battery packs, the weatherproof outer box also has space for accessories and system components. The exposed components are made of stainless steel, ABS, and engineering polymers. The OMS kit includes all necessary support rods, windproof balls, cables, battery packs, and adapters required for the use of SoundPro SE and DL instruments. Customers can also place the outer box on a fixed object using padlocks and cables.
Other options include:
+Real time spectrum analysis of 1/1 octave band
+Real time spectrum analysis of 1/3 octave band
+Acoustic Spectral Curve Options
+Voice clarity options
+Listening calibration component
+GPS data integration (using compatible GPS receivers)
+1/4 ", 1/2", and 1 "microphone sizes are optional
+Reverberation time (RT-60 option)
Sensor specifications
General
Display languages: English, French, Spanish, German, Italian, and Portuguese
10 function keys and 4 selection keys on the user interface, providing menu prompts
Display type 128 X 64 resolution LCD screen with backlight
function
meet the standard
EMC specification EN/IEC 61326-1 (2005) Group 1, Class BEmissions /Industrial Location Immunity.CFR:47 (2008) Part15 - Meets FCC Class B Emissions
performance
规格 EN/IEC61672-1(2002),ANSIS1.4(R2006), ANSIS1.43(R2007),EN/IEC61260(2001),ANSI S1.11 (R2009), (Also in compliance with earlier IEC 60651)and60804 standard)IEC60268-16 (2003) Voice Clarity Options
Safety specification IEC61010-1 (2010)
Certification of CE mark, WEEE, RoHS
physical properties
Size 3.1 "wide x 11.1" high x 1.6 "thick (including preamplifier and microphone);
7.9 cm x 28.2 cm x 4.1 cm
Weight 0.54 kg or 1.2 lbs. (including battery)
The outer shell is filled with ABS engineering plastic made of stainless steel fibers, which has internal EM/RFI shielding function
The back of the tripod fixed instrument has ¼ '-20 threaded holes for standard photographic equipment brackets
environmental parameters
Temperature operation temperature -10 º C~+50 º C (temperature effect<± 0.5 dB);
Storage temperature -25 º C~+70 º C
Humidity 10%~90% RH, non condensing
External electric field: 10V/meter, 1kHz modulation, 30MHz-1GHz,<55 dBC;
Magnetic field: 80 A/m, 50/60 Hz,No significant impact
measurement
Parameters SPL, LMax, LMin, LPk (peak), LEQ/LAVG, SEL, LN (optional L1 to) L99), TWA,Taktm,Taktmx,Dose, PDose, Exposure(Pa2H/Pa2S),LDN,CNEL,PTWA,LC-A
The total dynamic range is 120dB+(A-weighted), including over 8 dynamic ranges
Segmented range of 90 dB (A-weighted) (filtering dynamic range of 80dB);
The overall measurement range is 0-140dB
The peak range is up to 143 dB using the standard BK4936 microphone;
Optional microphones and preamplifiers with higher measurement range
Frequency weighting A, C, Z, and F (Flat)
Fast response time, slow response time, IEC pulse
Exchange rates of 3, 4, 5, and 6 dB
Threshold of 40~100 dB
Upper limit value 10~140 dB optional
Operation mode sound level triggers operation/stop, clock/date triggers power on and runs according to programmed time, external logic input runs/pauses, key directly triggers operation/pause within programmed time
Measurement reference SPL: 114 dB
Frequency: 1 kHz
Direction: 0 degrees, using a free field response microphone
Electrical Characteristics
4 disposable AA alkaline batteries, usually able to be used continuously without backlight
More than 10 hours (SLM only, no filter used); Optional nickel hydrogen compound battery (NIMH), typically capable of continuous use for more than 10 hours (SLM only)
External DC
Power input 100-240 VAC, 47-63Hz converted to 9 VDC
Standard microphone Type 1 accuracy - BK4936; Level 2 precision general purpose - QE7052; Other types and sizes of pre polarized or standard capacitor models from ¼ 'to 1' are available for selection
Microphone polarity 0 V or 200 V optional (Level 1 accuracy only)
The nominal sensitivity value of the microphone is optional, with a reference of 1Volt/Pa
instrument
Input impedance of 20 kW in series with an 11mF capacitor, grounded with a 100pF capacitor
Remote cables can drive cables up to 15 meters in length, with negligible signal loss
The preamplifier is detachable and can be directly connected to a half inch (0.52 inch or 13.2mm) microphone;
Other sizes require adapters
preamplifier
Input impedance greater than 1 GW; less than 2pF
Recording and Storage
Records are only supported for DL type. LMax, LMin, LPk (peak) LN, LEQ/LAVG data
Can be selected from 11 different sampling intervals ranging from 1 second to 60 minutes and stored in the insert
Inside the SD card. TSIQuest detection management software DMS can be used to analyze and process data.
All test sampling data are stored in the SD card for data aggregation. Can be detected using TSI Questmanagement
The software DMS is used for analysis and processing, and can also be exported to spreadsheet files or XML files.
The storage capacity can be used with 32 MB to 32 GB SD memory cards.
Interface and Connection
Power socket 9-16V DC external power supply
AC/DC output 3.5mm stereo headphone jack
10 needle assistance
Connect RS-232, 3 digital outputs, 1 digital input
USB complies with USB 2.0 standard, mini USB data cable
special function
Data erasure can choose to delete test data for 1-20 secondsThe data itself remains in the data file)
Security operation and settings can be set with a 4-digit password for permission settings
Optional acoustic spectrum noise standard curve (NC), preferred noise
Curve function
Spectral Curve Standard Curve (PNC), Room Standard Curve (RC), Balanced Noise Standard Curveline(NCB), Noise Level Curve (NR), Listening Room Curve (according to ANSI S3.1,OSHA Hearing Protection Amendment and ISO Hearing Room Hearing Screening Requirements
Optional voice clarity
The functional firmware is installed in the SoundPro series through a public address (PA) for fire alarmandMass Notification System (MNS), using STI-PA method, according to IEC 60268-16andNFPA 72 National Fire Alarm Standard is used to test and evaluate the speech clarity of broadcasting systems.The result is STI or CIS, and post-processing can be performed using instruments.
Optional reverb
Time (RT-60) is used to measure the time and degree of sound attenuation in a closed space or room
calibration
Complete calibration history data, including verification after calibration testing
Octave frequency filter (optional)
(Base-10 frequency band, recommended by IEC61260 [2001])
11 frequency bands with 1/1 octave center frequency from 16 Hz to 16 kHz
33 frequency bands with 1/3 octave center frequencies ranging from 12.5Hz to 20kHz