1: Product Overview
The SCYG414 flat film pressure transmitter takes the integrated silicon pressure resistance sensor as the core of the sensor, uses the flat film to directly sense the pressure signal, and the built-in processing circuit converts the sensor millivolt signal into standard voltage, current, and digital signal output, which can be directly connected with computers, control instruments, display instruments, etc., and can carry out remote signal transmission. The end face of the flat membrane pressure transmitter sensor is exposed to directly sense pressure, which can prevent problems such as scaling, unhygienic, and viscous pressure blockage.
This product is widely used in industries such as medicine, food, brewing, dairy products, beverages, etc. where viscosity is prone to clogging and requires high hygiene standards for convenient cleaning; Pressure testing for industries such as environmentally friendly chemical coatings, polyurethane equipment, paint detection systems, and measurement media where scaling may occur. Select the clamp flat film, cavity free flat film, and flange flat film leveling measurement method according to the customer's operating conditions.
2: Product Features
1. Stainless steel structure, small size, light weight, anti-interference, corrosion-resistant
2. High precision, high output, shock resistance, and vibration resistance
3. Wide voltage power supply, multiple pressure interfaces
4. Equipped with short-circuit protection and reverse polarity protection
3: Typical applications
1. Disinfection and sterilization industry
2. Food and pharmaceutical industries
3. Chemical and biological science industries
4. Ultra pure water equipment industry
4、 Performance indicators
Range |
-100kPa... 0kPa~10kPa... 100MPa Full range coverage |
Overvoltage |
≤ 1.5 times the full range pressure or 110MPa (consult technical personnel for details) |
pressure type |
Gauge pressure, absolute pressure, sealed gauge pressure type |
Accuracy |
±0.1%FS ±0.25%FS ±0.5%FS |
Long term stability |
≤± 0.3% FS/year (specific consultation with technical personnel) |
Zero temperature error |
≤±0.05%FS/℃(≤100kPa); ≤±0.03%FS/℃(>100kPa) |
Full temperature error |
≤±0.05%FS/℃(≤100kPa); ≤±0.03%FS/℃(>100kPa) |
compensation temperature |
0℃~60℃ |
ambient temperature |
-20~60℃ |
medium temperature |
-40℃~85℃; -40℃~150℃ |
power supply |
9V~36V DC |
output signal |
mV 0~5V/10V 4~20mA |
protection grade |
IP65 (plug-in type) IP67 (cable straight out type) |
Electrical connection |
Husman connector, straight out cable, aviation plug |
Shell |
Stainless steel 1Cr18Ni9Ti |
5: Selection Table

Please contact the sales engineer to assist you in selecting and confirming specific technical parameters.
6: Outline structure diagram

Selection reminder:
When selecting, please pay attention to the compatibility between the tested medium and the contact part of the product.
If the ordered product requires a metrological verification certificate or other special requirements, please consult with our company and indicate it in the order.