Research grade fertilizer nutrient detector
The scientific research grade fertilizer nutrient detector adopts an integrated aluminum alloy case with a chassis/agent, which is easy to carry, stur
Product details
Research grade fertilizer nutrient detectorAdopting the integrated aluminum alloy chassis for chassis/chemicals, it is easy to carry, sturdy and durable, equipped with finished chemicals, microcomputer control, digital circuits, programmed design, LCD display, AC/DC dual-use, can be used for field flow testing, greatly reducing operator errors and labor intensity. Resolution: 0.001, touch buttons, built-in thermal printer, can print test results. The soil fertilizer nutrient detector for the entire project can detect soil and fertilizers, organic fertilizers (including foliar fertilizers, water-soluble fertilizers, spray fertilizers, etc.), available nitrogen, available phosphorus, available potassium, total nitrogen, total phosphorus, total potassium, organic matter, acidity and alkalinity, calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, etc. in plants. The content of various trace elements and heavy metals such as lead, chromium, cadmium, mercury, arsenic, etc.
Adopting high brightness LED light source and dual dial filter processing technology to ensure stable wavelength of the light source, silicon semiconductor is used as the signal receiving system with a lifespan of up to 100000 hours. The light source is stable, with good reproducibility and high accuracy. The colorimetric groove adopts a single channel design, without mechanical displacement or wear. The optical path testing positioning is precise, ensuring the accuracy of the measurement results. It is equipped with an expert fertilization system data, which can scientifically calculate the recommended fertilization amount for more than 100 national agricultural, fruit tree, and economic crop target yields, ensuring that the detection results meet the national standard requirements.

Functions and testing items of scientific research grade fertilizer nutrient detector
1. Soil nutrients: nine items including ammonium nitrogen, nitrate nitrogen, available phosphorus, available potassium, organic matter, total nitrogen, pH value, moisture, and alkali hydrolyzed nitrogen; ● Medium and trace elements: calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, etc.
2. Fertilizer nutrients: ● Nitrogen, phosphorus, and potassium in elemental fertilizers; Ammonium nitrogen, nitrate nitrogen, phosphorus, potassium, and urea in compound (mixed) Hefei and urea; Available nitrogen, available phosphorus, available potassium, total nitrogen, total phosphorus, total potassium, organic matter, various humic acids, trace elements (calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon), etc. in organic fertilizers.
3. Plant nutrients: ● Nitrogen, phosphorus, and potassium in the plant; Nitrates and nitrites; Calcium, magnesium, sulfur, iron, manganese, boron, zinc, copper, chlorine, silicon, etc.
4. Nutrients of tobacco leaves: 20 items including total nitrogen, total phosphorus, total potassium, reducing sugars, water-soluble total sugars, boron, manganese, iron, copper, calcium, magnesium, etc.
5. Soil and fertilizer heavy metals: nearly ten heavy metals such as lead, chromium, cadmium, arsenic, mercury, etc.
6. Food (fruits, vegetables, etc.): nitrate, nitrite, heavy metals (lead, chromium, cadmium, arsenic, mercury), etc.
7. Water quality: ● Ammonium nitrogen, nitrate, nitrite, phosphorus, potassium, hardness PH、 Iron, copper, manganese, zinc, boron, chlorine, sulfur, silicon, etc.
Technical indicators of scientific research grade fertilizer nutrient detection instruments
1. Power supply: AC 220 ± 22V DC 12V+5V (can be powered by a car power supply or choose the instrument's built-in lithium battery) 2. Power: ≤ 5W
3. Range and Resolution: 0.001-9999
4. Repeatability error: ≤ 0.05% (0.0005, potassium dichromate solution) 5. Instrument stability: Drift less than 0.3% within one hour (0.003, transparency measurement). After the instrument is turned on and preheated for 5 minutes, there will be no drift in the displayed numbers within 30 minutes (transparency measurement); The numerical drift within one hour shall not exceed 0.3% (for transparency measurement) and 0.001 (for absorbance measurement); The digital drift within two hours should not exceed 0.5% (0.005, measured for transparency).
6. Linear error: ≤ 0.2% (0.002, copper sulfate detection)
7. Sensitivity: Red light ≥ 4.5 × 10-5 Blue light ≥ 3.17 × 10-3 Green light ≥ 2.35 × 10-3 Orange light ≥ 2.13 × 10-3
8. Wavelength range: Red light: 680 ± 2nm; Blue light: 420 ± 2nm; Green light: 510 ± 2nm; Orange light: 590 ± 4nm
9. PH value (pH): (1) Test range: 1~14 (2) Accuracy: 0.01 (3) Error: ± 0.1
10. Salt content (conductivity): (1) Test range: 0.01%~1.00% (2) Relative error: ± 5%
11. Soil moisture technical parameters Water unit:% (g/100g); Moisture content testing range: 0-100%; Error less than 0.5%
12. Simultaneous extraction and determination of efficient N, P, and K nutrients in soil, and scientific recommendation of fertilizer application rates
13. Simultaneous, rapid, and accurate detection of nutrients such as nitrogen (N), phosphorus (P), and potassium (K) in fertilizers
14. Testing speed: Test a soil sample (N, P, K) for ≤ 30 minutes (including pre-treatment time, without the need for any attachments from the user)
15. Simultaneously test 8 soil samples for ≤ 1 hour (including pre-treatment time)
8. Wavelength range: Red light: 680 ± 2nm; Blue light: 420 ± 2nm; Green light: 510 ± 2nm; Orange light: 590 ± 4nm
9. PH value (pH): (1) Test range: 1~14 (2) Accuracy: 0.01 (3) Error: ± 0.1
10. Salt content (conductivity): (1) Test range: 0.01%~1.00% (2) Relative error: ± 5%
11. Soil moisture technical parameters Water unit:% (g/100g); Moisture content testing range: 0-100%; Error less than 0.5%
12. Simultaneous extraction and determination of efficient N, P, and K nutrients in soil, and scientific recommendation of fertilizer application rates
13. Simultaneous, rapid, and accurate detection of nutrients such as nitrogen (N), phosphorus (P), and potassium (K) in fertilizers
14. Testing speed: Test a soil sample (N, P, K) for ≤ 30 minutes (including pre-treatment time, without the need for any attachments from the user)
15. Simultaneously test 8 soil samples for ≤ 1 hour (including pre-treatment time)
16. Data printing: Built in one click thermal printer
Test speed:
Test one soil sample (N, P, K) for ≤ 30 minutes, and simultaneously test three soil samples (N, P, K) for ≤ 40 minutes; Test one fertilizer sample (N, P, K) for ≤ 50 minutes, and simultaneously test three fertilizer samples (N, P, K) for ≤ 1.5 hours.
Test error:
Soil error ≤ 5%; The single error of fertilizer is ≤ 0.5%, and the error of nitrogen, phosphorus, and potassium is ≤ 1%
Research grade fertilizer nutrient detection instrument product characteristics
The soil fertilizer nutrient detector for the entire project is fully functional (all kinds of chemicals can be purchased).
Fully equipped: This instrument integrates medicine, equipment, and instruments, making it easy to carry and equivalent to a small laboratory. Suitable for agricultural service departments or agricultural material distributors, fertilizer manufacturers to conduct soil testing and fertilization, and to identify the authenticity of fertilizers.
Easy to operate and fast, the finished medicine can be used immediately after opening the bottle, without the need for configuration.
After sales service for scientific research grade fertilizer nutrient detection instruments
The entire instrument comes with a five-year warranty, lifetime free maintenance services, free shipping of instruments, and free training.
Lifetime free agricultural related technical support such as soil and fertilizer!
Configuration List (FT-TFD Type, Two Aluminum Alloy Boxes):