Flite2Programmable pump for asbestos and other high flow air sampling pumps
Flite Company 2 Download
- Wide flow range: 2? 26 liters/minute to free air
-
Fully programmable
- Manual operation
- Timed operation and delayed startup
- intermittent sampling
- Sturdy steel casing
- Durable handle, easy to carry
- Long running time
- High performance sampling capability
- Convenient front-end power socket
- Battery or AC operation
-
Flow fault function ensures the integrity of the sample
- Reserved for displaying fault running time
Highly flexible SKCFliteTwo air sampling pumps provide high-performance sampling of asbestos and other particles. A sturdy steel casing can withstand the harshness of daily life, with a front mounted power outlet for charging or supplying power, and a sturdy handle for easy portability and convenience,Flite2 is the top choice for most high traffic sampling applications. Use fully programmable timer settings to manually run with or without delay start, timed run, or intermittent sampling. Flite2 area and environmental monitoring, stack sampling, indoor air research, asbestos monitoring, biosampling, Ideal choice for long-term backend monitoring.
Flite2application
|
|
Introduction to the Performance of Fleet2
Flow range | 2 to 26 liters per minute to free air |
operation temperature | 23 to 122 ° F (-5 to 50 ° C) |
battery | Lead acid |
size | 7 x 4.3 x 7.9 inches (18 x 11 x 20 centimeters) |
weight | 15 pounds (6.9 kilograms) |
Typical running time*
filter |
Flow rate (liters/minute) |
Running time (hours) |
25mm MCE, 0.8 microns |
4 |
24 |
25mm MCE, 0.8 microns |
8 |
12 |
25mm fiberglass |
8 |
20 |
25mm fiberglass |
12 |
12 |
47mm fiberglass |
16.67 |
6 |
47mm MCE, 0.8 microns |
16.67 |
4 |
* | The performance of the pump and battery may vary when using a fully charged new battery in a clean room. |
ordering information
Flite2Requires a 4-inch ID tube
describe | plug |
voltage |
Model |
Flite2 only sampling pump | many |
100-240 V |
901-2011 |
Flite2Pump kitIncluding 3.2 lightweight batteries, chargers, and a 1-meter polyethylene tube and sampling pump | many |
100-240 V |
901-2011-3K |
Flite2Sampling pumpPump accessory kitIncluding 7-AH battery with long running time, charger, and 1-meter polyethylene pipe | many |
100-240 V |
901-2011-7000 |
Sampling attachments | |||
Rigid aluminum sampling hypertrophy | 901-213 |
||
Asbestos sampling head,25mm, covered with plastic | 225-54 |
||
Asbestos sampling head,25mm, with aluminum cover | 225-54A |
||
Power accessories
| |||
Battery Charger | many |
100-240 V |
901-210 |
ac adapter | many |
100-240 V |
901-211 |
Replacing lead-acid batteries,3.2 Ah capacity | P901201 |
||
Replacing lead-acid batteries,7 Ah capacity | P901202 |