On the basis of designing and developing various types of medium and low temperature refrigeration equipment, Shenzhen Lixiang Refrigeration Equipment Co., Ltd. can undertake general contracting of various refrigeration complete sets of projects externally; We mainly provide one-stop services for the design, construction, installation, commissioning, and maintenance of complete engineering projects such as concrete cooling, mixing chilled water systems, mine cooling chilled water systems, industrial production process cooling water/chilled water systems, industrial hot and cold water systems, food freezing and refrigeration systems, aquatic product quick freezing systems, process air conditioning regulation systems, and various environmental simulation laboratory projects.
Our company has long been supporting various refrigeration equipment in the chemical, pharmaceutical, industrial and mining, food and other industries. We have rich practical experience in the design and construction of industrial refrigeration complete sets of projects, and can provide customers with integrated refrigeration process solutions for refrigeration equipment production and manufacturing, engineering system design and planning, construction and installation, maintenance and repair - various industrial refrigeration system solutions with temperature ranges from+30 ℃ to -80 ℃.
1、 Industrial process cooling/chilled water system complete project:
We can provide customers with complete solutions for process cooling and freezing from+30 ℃ to -80 ℃; For example:
*-3 ℃ -+2 ℃ concrete mixing chilled water, 5 ℃ -7 ℃ concrete pouring cooling water system
*High temperature process cooling water at 7 ℃ -30 ℃; Or high-temperature water and large temperature difference cooling treatment process;
*0 ℃ -10 ℃ ambient temperature cooling water and large temperature difference cooling treatment process;
*-35 ℃ -0 ℃ medium low temperature process cooling system; Pharmaceutical and chemical process cold source;
*-80 ℃ to -35 ℃ ultra-low temperature process refrigeration system; Pharmaceutical and chemical process cold source
*Ice water mixing process cooling system; Suitable for process locations with high instantaneous loads such as liquid milk pasteurization cooling, rapid cooling in food processing, and concrete mixing cooling.
2、 Industrial gas cooling (condensation) and recovery complete set project:
*Various industrial production processes such as gas cooling, liquefaction, and recovery are applicable to natural gas cooling, ammonia cooling, and other toxic cooling, liquefaction, and recovery processes generated in industrial production;
*Complete system engineering for vapor cooling, condensation, separation and recovery of pharmaceutical and chemical raw materials;
*The minimum temperature can be -80 ℃; Including the design and engineering construction of various refrigeration hosts and gas heat exchangers
3、 Complete set of freezing and refrigeration engineering
Various large, medium, and small cold storage engineering projects; Storage temperature range+15 ℃~-70 ℃;
Tuna ultra-low temperature refrigeration warehouse complete set project, with storage temperature ranging from -45 ℃ to -60 ℃;
Liquid contact quick freezing and flat shelf quick freezing complete set project (temperature -40 ℃~-70 ℃);
4、 Mine cooling and dust removal complete set project
*The main heat sources in coal mines include: heat release from surrounding rock in tunnels, heat release during coal transportation, compression heat from downward (or upward) airflow, heat generated during the operation of mechanical and electrical equipment, oxidation heat release, and other heat sources. Due to the depth of mining, the ambient temperature at -925 meters level exceeds 37 ℃, making it a second level heat hazard zone. The entire system is composed of a ground refrigeration system, an ice water system, and an underground cooling and dispersing system. In reality, the underground cooling and dispersing system is an open system, where the return water flows back to the melting ice pool. The dust prevention water in the mining area, which is a small amount of water, can be connected from the cold water supply pipeline for dust prevention and spray cooling on the working face, effectively reducing the temperature of the underground environment and improving production efficiency. Ensure safe underground operations.
*It is to establish a refrigeration station near the wellhead on the ground, and generate low-temperature refrigerant of -5 ℃± 1 ℃ through refrigeration units or other pre cooling devices. By exchanging heat with purified water through plate heat exchangers, the water is cooled to 2 ℃± 0.5 ℃ and transported to the underground of the mine through pipelines. Directly spray chilled water onto the work area through a nozzle
*Low temperature water with a temperature of 2 ℃± 1 ℃ is transported by a cold water pump to the pipeline installed in the mining face machine roadway, and the chilled water is directly sprayed onto the working area through a nozzle to achieve cooling underground in the coal mine. Not only does it have cooling and dust removal effects, which traditional mine cooling cannot achieve. This process has low operating costs, good cooling effects, and does not pollute the environment.