Beijing Beifen Raleigh Analytical Instrument (Group) Co., Ltd
Home>Products>RWL-1000 spark photoelectric direct reading spectrometer
RWL-1000 spark photoelectric direct reading spectrometer
technology
Product details
RWL-1000 spark photoelectric direct reading spectrometer

overview

technology

A digital parallel acquisition system based on FPGA, with proprietary IVF conversion receivers for all channels, achieving a high-speed, high-precision, and highly integrated measurement and control system with higher and more stable measurement accuracy.

Innovative Design

Spark power supplies have dozens of excitation conditions to meet the analysis of different materials and purities.

A brand new concept

High degree of automation, simple operation, capable of continuous high-intensity work, the best choice for enterprise process control.

Higher starting point

The RWL-1000 R&D team has gathered several well-known experts and researchers in the fields of optics, mechanics, electronics, software, etc. who have been working in the industry for decades; All R&D personnel have a bachelor's degree or above and have many years of experience in instrument development. The R&D team is led by several senior engineers, consolidating decades of R&D expertise.

higher quality

The problem of failure rate in the instrument industry has always been criticized. In order to improve instrument reliability, all key components of RWL-1000 come from top international manufacturers; More than 90% of electronic components are imported from overseas with original packaging.

higher level

Using the Paschen Runge apparatus with a focal length of 1 meter, compared to shorter focal length instruments, it has good imaging quality and high resolution, making it a symbol of high-performance and high-end instruments.

A comprehensive service system

Localized service system to ensure timely delivery of services;

Advanced customer management system, providing full lifecycle tracking services for each instrument, relieving customers' worries.

application area

Instruments are widely used in various industries such as casting, metallurgy, various machinery manufacturing, shipbuilding, automotive, chemical, electronics, etc. They are necessary instruments for rapid quantitative analysis before metallurgical furnaces, testing of incoming materials, and quality monitoring of metal materials in laboratories and product material analysis fields.

Performance characteristics

Precise optical system

Using the Paschen Runge apparatus with a focal length of 1 meter, compared to shorter focal length instruments, it has good imaging quality and high resolution, making it a symbol of high-performance and high-end instruments.

Multiple customized options for engraved gratings to meet the testing needs of different customers.

The overall slit technology reserves multiple channels for users to add and change channels, saving costs.

Accurate constant temperature system

Constant temperature of 38 ° C ± 0.1 ° C, suitable for different on-site environmental requirements. Ensure long-term stability of the instrument.

Using special casting materials with low thermal expansion coefficient and natural stress relief.

Stable vacuum shock absorption system

Using imported high-end vacuum pumps, with low noise and strong reliability, it can maintain a low vacuum degree in the spectral chamber for a long time.

Pioneering the use of adsorption trap solenoid valve technology, effectively preventing oil vapor from entering the light chamber and protecting optical components.

Special shock resistant design ensures the stability of the instrument.

Unique Inspiration Platform

• Argon saving design

Combination argon gas regulating valve, optimized flow design, minimal argon gas consumption, operating costLow.

• Lens design

The lens is easy to disassemble and clean, reducing maintenance time.

Flexible moving compression rod

Adapt to samples of different specifications and shapes. And small sample fixtures (optional) can be provided.

High reliability light source

• Digital control technology

The excitation light source adopts precision digital control technology to stabilize the spark discharge frequency and improve excitation consistency.

• Customized lighting conditions

Dozens of excitation conditions to meet different material analysis requirements; Matching different light source parameters for different channels of the same sample,improveMeasurement accuracy and detection limit.

• Integrated design

Integrated design of spark light source and excitation stage, multiple Faraday cage shielding structures are used to avoid electromagnetic interference and harm to human bodyHarm.

High speed measurement and control system

Parallel high-speed acquisition

A digital parallel acquisition system based on FPGA, where all channels have their own dedicated conversion receivers,Realize high speed and efficiencyA precise and highly integrated measurement and control system.

• Digital Points

The acquisition system adopts analog filtering digital integration circuit, which eliminates the disadvantage of large quantization error in traditional segmented integration technology,carryHigher element measurement range.

High precision adjustable negative high voltage

Voltage stability ≤ 0.01%; Temperature drift ≤ 0.0025%; The negative high voltage program is adjustable, expanding the range of element analysis.

• Intelligent monitoring

Intelligent monitoring system for various data and real-time diagnostic functions.

Multifunctional software

Global standardization, local standardization, type standardization, monitoring sample analysis

• Database storage (standard sample library, brand library, analysis result library)

Automatically switch channels based on the range of element content

• Customize printing templates

Custom output statistical results (AVG, SD, RSD)

• Automatic program selection

• Historical data query

• User permission management

Pre combustion curve, convenient for selecting the optimal analysis parameters

Based on customer needsSet the original factory calibration curve and provide international SUS standard samples. Users do not need to provide standard sample productionCurve.

Multi mode output test results (absolute intensity relative intensity standardized intensity interference corrected intensity apparent concentration channel)Concentration element content

Laboratory environment requirements

Temperature: 15 ℃~30℃

Relative humidity: 20%~80%, no water vapor condensation

Power requirements: 220V ± 22V, current 10A, single item 50Hz, grounding resistance<2Q

Size: 1800mm (L) x1050mm (W) x1245mm (H)

Instrument weight: 500kg, power consumption: 2.8kVA