When an oxygen process application requires high precision and stability, as well as minimal maintenance costs, paramagnetic oxygen technology is usually prioritized. If the application also requires a robust, reliable, and corrosion-resistant analyzer, the latest XTP600 series thermal magnetic principle from Michell is the best choice.
highlight
- Excellent accuracy of less than 1% of full scale ensures that the range can be reset without the need for further verification.
- Excellent zero or range stability: 0.25% of the range per month
- Innovative sensor design means zero drift and no background gas influence
- Enhanced protection against pollution
- Two 4-20 mA input signals are provided to the process variable for dynamic compensation
- The two isolated outputs and local display inside the explosion-proof enclosure are suitable for both local and remote installation
- Simplify maintenance to minimize user costs
|
 |
technical indicators
|
|
performance |
|
| Thermomagnetic oxygen sensor |
|
| gas |
Process gas or non condensing gas |
| Measurement range |
Any oxygen content from 0~1% to 0~25% (special ranges, such as 0~100%, please consult first) |
| precision |
Better than ± 1% of the range |
| Response time (T90) |
70 seconds. If you need faster, please consult. |
| repetitiveness |
± 0.2% of the measuring range |
| linear |
Beyond the range of 0-5% is ± 0.5% of the measurement range Within the range of 0-5%, it is better than ± 1% of the measuring range |
| Zero stability |
± 0.25% of the measurement range per month |
| span stability |
± 0.25% of the measurement range per month |
| Sample gas flow rate |
Sensing section 0.4 l/min |
| Maximum sample gas pressure |
Normal pressure to a maximum of 300 kPa |
| Maximum sample gas temperature |
Up to 45 ° C (please consult for higher temperatures first) |
|
Electronic input/output |
|
| output signal |
Two 4~20 mA linear signals with safety isolation (one for oxygen and the other for background gas) |
| input |
Two 4~20 mA inputs for external background gas and pressure compensation |
| output range |
0 ~ 1%; 2%; 5%; 10%; 25% (for higher ranges such as 0~100%, pressure compensation is required) |
| display resolution |
0.1% within the range of 0-25% |
| power supply |
24 V DC , Maximum current of 1.5 A |
|
working conditions |
|
| ambient temperature |
0°C ~ +45°C |
|
Mechanical indicators |
|
| warm-up time |
30 Minutes |
| size |
213mm x 180mm x 140mm |
| weight |
6.3kg |
| Sealing material |
AISI 316 and viton, other materials on request |
| Gas interface |
1/4” NPT (f) |
| Protection level |
IP65。 Additional flame arresters are provided for hazardous applications |
|
other |
|
| Dangerous Place Certificate |
II 2 GD Exd IIC T4 Gb II 2 D Extb IIIC T135°C Db IP66 T Amb -50°C/+60°C |
| Ship certification |