Oven Tracker DQ type/Furnace Temperature Tracker DQ type/Furnace Temperature Tracker DQ type:
Oven Tracker DQ type furnace temperature tracker, including Chinese version analysis software (including Chinese operation manual, computer connection CI3029 or CI1020), Data Logger DQ1860A (replacing DP9061A and DP9064A) DQ0441A (replacing DP4046A), DQ1862 (replacing DP9161A and DP9069A), DQ1861, DQ1801, DQ1812, Thermal Barrier Insulation Box TB0045 TB0046、TB5000、TB4005、TB2036、TB2015、TB2065、TB2021、TB2020、TB2065、TB2066、TB2067、TB2068、TB2061、TB2062、TB2081、TB2082、 A set of probes.
![]() |
![]() |
DQ1860 | DP9061A/DP9064A (discontinued) |
Data Logger: DQ1860 USB interface 6-channel |
Range:- 200℃ to 1370℃ |
Accuracy: ± 0.5 ℃ |
Resolution: 0.1 ℃ |
Working temperature: 0 ℃ to 85 ℃ (automatic shutdown) |
Size: 11.7 x 106 x 150 mm, weight 0.4Kg |
Storage capacity: 18000 data/channels |
Power supply: Nickel hydrogen rechargeable battery fast charging for 1 hour/standard charging for 8 hours |
Sampling interval: adjustable from 0.05 seconds to 10 minutes |
TB5000 Thermal Barrier
→ Insulation box TB5000 (including two heat absorbing blocks TB1001, suitable for DQ1860/Tpaq21, can be used for non stick coating) |
|||
weight |
size |
temperature |
Adiabatic time |
6.2 |
130 (high) |
100 |
870 |
190 (width) |
150 |
390 |
|
292 (long) |
200 |
270 |
|
250 |
210 |
||
300 |
180 |
→ Insulation box TB4005 (including one heat absorbing block, suitable for DQ1860/Tpaq21, used for enamel and glass powder curing) |
|||
weight |
size |
temperature |
Adiabatic time |
6.2 |
125 (high) |
200 |
360 |
248 (width) |
400 |
120 |
|
409 (long) |
800 |
60 |
Insulation box TB0045 (applicable to DQ1860 data collector) |
Weight (kg) 1.5 |
Dimensions (mm) 48 (height) × 185 (width) × 223 (length) |
Temperature (℃) 100 150 200 250 |
Adiabatic time (minutes) 80 45 35 30 |
Insulation box TB0046 (applicable to DQ1860 data collector) |
Weight (kg) 2.4 |
Dimensions (mm) 70 (height) x 195 (width) x 240 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 120 60 45 35 25 |
Insulation box TB2028 (applicable to DQ1860 data collector) |
Weight (kg) 0.2 |
Dimensions (millimeters) 24 (height) × 136 (width) × 195 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 9 |
Insulation box TB2003 (applicable to DQ1860 data collector) |
Weight (kg) 1.5 |
Dimensions (mm) 40 (height) × 162 (width) × 216 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 45 25 20 18 15 |
Insulation box TB5001 (applicable to DQ1860/Tpaq21 data collector) |
Weight (kg) 2.8 |
Dimensions (millimeters) 75 (height) x 176 (width) x 292 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 125 65 54 45 40 |
Insulation box TB5004 (applicable to DQ1860 data collector) |
Weight (kg) 4.2 |
Dimensions (millimeters) 50 (height) × 229 (width) × 271 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 285 165 105 75 60 |
Insulation box TB5006 (applicable to DQ1860 data collector) |
Weight (kg) 7 |
Dimensions (millimeters) 156 (height) × 190 (width) × 303 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 870 390 270 210 180 |
Insulation box TB2005 (applicable to DQ1860 data collector) |
Weight (kg) 4.2 |
Dimensions (mm) 68 (height) × 188 (width) × 368 (length) |
Temperature (℃) 200 250 300 400 800 |
Adiabatic time (minutes) 45 37 30 22 10 |
Insulation box TB2015 (applicable to DQ1860 data collector) |
Weight (kg) 0.7 |
Dimensions (millimeters) 25 (height) × 133 (width) × 210 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 13 10 9 |
Insulation box TB2065 (applicable to DQ1860 data collector) |
Weight (kg) 0.7 |
Dimensions (mm) 29 (height) × 133 (width) × 210 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 13 11 10 |
DQ1862
Data Logger DQ1862 USB interface 6-channel |
Range -200 ℃ to 1370 ℃ |
Accurate ± 0.5 ℃ |
Resolution 0.1 ℃ |
Working temperature: 0 ℃ to 85 ℃ (automatic shutdown) |
Size 20 x 57 x 165 mm, weight 0.3Kg |
Storage capacity of 18000 data/channels |
Power supply: Nickel hydrogen rechargeable battery, fast charging for 1 hour/standard charging for 8 hours |
Sampling interval adjustable from 0.05 seconds to 10 minutes |
Thermal Barrier TB2028 (applicable to DQ1862 data collector) |
Weight (kg) 0.2 |
Dimensions (millimeters) 24 (height) × 136 (width) × 195 (length) |
Temperature (℃) 100 150 200 250 300 |
Adiabatic time (minutes) 9 |
→ Insulation box TB2036 (applicable to DQ1862A/DP9069A/DP9161A) |
|||
weight |
size |
temperature |
Adiabatic time |
2.25 |
83 (high) |
100 |
300 |
127 (width) |
200 |
138 |
|
290 (length) |
300 |
78 |
Insulation box TB2020 (applicable to DQ1862 data collector) |
Weight (kg) 0.5 |
Dimensions (mm) 28 (height) x 84 (width) x 233 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 25 13 10 8 7 |
Insulation box TB2021 (applicable to DQ1862 data collector) |
Weight (kg) 0.65 |
Dimensions (mm) 35 (height) x 84 (width) x 233 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 36 18 13 11 10 |
Data Logger DQ1861 USB interface 6-channel | |
Range -200 ℃ to 1370 ℃ |
|
Accurate ± 0.5 ℃ |
|
Resolution 0.1 ℃ |
|
Working temperature: 0 ℃ to 85 ℃ (automatic shutdown) |
|
Size 12 x 62 x 302 mm, weight 0.4Kg |
|
Storage capacity of 18000 data/channels |
|
Power supply: Nickel hydrogen rechargeable battery, fast charging for 1 hour/standard charging for 8 hours |
|
Sampling interval adjustable from 0.05 seconds to 10 minutes |
|
|
|
Weight (kg) 0.65 |
|
Dimensions (millimeters) 20 (height) x 88 (width) x 334 (length) |
|
Temperature (℃) 100 150 200 250 280 |
|
Adiabatic time (minutes) 8 6 6 |
Insulation box TB2067 (applicable to DQ1861 data collector) |
Weight (kg) 0.65 |
Dimensions (mm) 25 (height) x 88 (width) x 334 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 11 10 8 |
Insulation box TB2068 (applicable to DQ1861 data collector) |
Weight (kg) 0.80 |
Dimensions (mm) 29 (height) x 88 (width) x 334 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 13 11 10 |
Data Logger DQ1810 USB interface with 10 channels |
Range -200 ℃ to 1370 ℃ |
Accurate ± 0.5 ℃ |
Resolution 0.1 ℃ |
Working temperature: 0 ℃ to 85 ℃ (automatic shutdown) |
Size 20 x 60 x 221 mm, weight 0.3Kg |
Storage capacity of 18000 data/channels |
Power supply: Nickel hydrogen rechargeable battery, fast charging for 1 hour/standard charging for 8 hours |
Sampling interval adjustable from 0.05 seconds to 10 minutes |
Insulation box TB2061 (applicable to DQ1810 data collector) |
Weight (kg) 0.60 |
Dimensions (mm) 28 (height) x 88 (width) x 258 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 10 8 7 |
Insulation box TB2062 (applicable to DQ1810 data collector) |
Weight (kg) 0.60 |
Dimensions (mm) 35 (height) x 88 (width) x 258 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 13 11 10 |
Data Logger DQ1812 USB interface 12 channels |
Range -200 ℃ to 1370 ℃ |
Accurate ± 0.5 ℃ |
Resolution 0.1 ℃ |
Working temperature: 0 ℃ to 85 ℃ (automatic shutdown) |
Size 20 x 60 x 237 mm, weight 0.4Kg |
Storage capacity of 18000 data/channels |
Power supply: Nickel hydrogen rechargeable battery, fast charging for 1 hour/standard charging for 8 hours |
Sampling interval adjustable from 0.05 seconds to 10 minutes |
Insulation box TB2081 (applicable to DQ1812 data collector) |
Weight (kg) 0.60 |
Dimensions (mm) 28 (height) x 88 (width) x 274 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 10 8 7 |
Insulation box TB2082 (applicable to DQ1812 data collector) |
Weight (kg) 0.60 |
Dimensions (mm) 35 (height) x 88 (width) x 274 (length) |
Temperature (℃) 100 150 200 250 280 |
Adiabatic time (minutes) 13 11 10 |
Probe probe
Probe probe
model |
product name |
specifications |
length |
temperature |
purpose |
sketch |
PA0011 |
Fixture workpiece |
K |
1.5 meters |
0-265℃ |
Non magnetic products |
|
PA0012 |
Fixture workpiece |
K |
3.0 meters |
|||
PA0016 |
Fixture workpiece |
K |
6.0 meters |
|||
PA0021 |
Fixture air |
K |
1.5 meters |
0-265℃ |
Non magnetic products |
|
PA0022 |
Fixture air |
K |
3.0 meters |
|||
PA0025 |
Fixture air |
K |
6.0 meters |
|||
PA0053 |
Magnetic workpiece |
K |
1.5 meters |
0-265℃ |
Magnetic Products |
|
PA0054 |
Magnetic workpiece |
K |
3.0 meters |
|||
PA0050 |
Magnetic workpiece |
K |
6.0 meters |
|||
PA0055 |
Magnetic air |
K |
1.5 meters |
0-265℃ |
Magnetic Products |
|
PA0056 |
Magnetic air |
K |
3.0 meters |
|||
PA0059 |
Magnetic air |
K |
6.0 meters |
|||
PA0973 |
MicroMag magnetic workpiece |
K |
1.5 meters |
0-265℃ |
Magnetic Products |
|
PA0974 |
MicroMag magnetic workpiece |
K |
3.0 meters |
|||
PA0975 |
MicroMag magnetic workpiece |
K |
6.0 meters |
|||
PA0995 |
MicroMag magnetic air |
K |
1.5 meters |
0-265℃ |
Magnetic Products |
|
PA0996 |
MicroMag magnetic air |
K |
3.0 meters |
|||
PA0999 |
MicroMag magnetic air |
K |
6.0 meters |
|||
PA0061 |
Paste probe |
K |
1.0 meter |
0-265℃ |
Infrared heating |
|
PA0060 |
Paste probe |
K |
1.5 meters |
|||
PA0062 |
Paste probe |
K |
3.0 meters |
|||
PA0066 |
Paste probe |
K |
5.0 meters |
|||
PA0063 |
Exposure probe |
K |
1.5 meters |
0-265℃ |
Using spot welding |
|
PA0065 |
Exposure probe |
K |
2.0 meters |
|||
PA0064 |
Exposure probe |
K |
3.0 meters |
|||
PA0071 |
Exposure probe |
K |
8.0 meters |
|||
PA0182 |
500 degree probe |
K |
1.5 meters |
0-500℃ |
|
|
PA0181 |
500 degree probe |
K |
2.0 meters |
|||
PA0180 |
500 degree probe |
K |
3.0 meters |
|||
PA0183 |
500 degree probe |
K |
5.0 meters |
|||
PA0830 |
High temperature probe |
K |
1.0 meter |
0-700℃ |
|
|
PA0831 |
High temperature probe |
K |
2.0 meters |
|||
PA0081 |
Gasket probe |
K |
1.5 meters |
0-265℃ |
|
|
TC22-200 |
High temperature probe |
K |
2.0 meters |
0-1250℃ |
|
|
TC22-300 |
High temperature probe |
K |
3.0 meters |