Open type bypass flow processor
Open type bypass flow processor
Product details

Product Introduction

The YLD - ∥ series bypass circulating water processor is a new generation product developed on the basis of the original full flow water processor. The product adopts the principle of pulse type low-voltage electric field and automatically adjusts the working output signal according to changes in water quality. After treatment by a water processor, the aggregation degree of water molecules decreases and the structure changes, such as an increase in the dipole distance and polarity of water molecules, an increase in surface tension, thereby increasing the ability of water molecules to dissolve scale and achieving the goal of scale removal.

Under the action of electrodes, the processor generates a large number of tiny crystals with excellent anti scaling function, which can remove scaling ions from water and form loose aragonite crystals, which are discharged through an automatic drain valve. The water processed by the processor activates dissolved oxygen, and under the electrolysis of the electrode, a large amount of OH ˉ, O2 ˉ, H2O2, and a large amount of reactive oxygen species are produced in the water. These substances have strong oxidizing properties and can completely kill microorganisms and various algae in the water, thereby achieving excellent bactericidal and algaecidal functions and preventing the formation of scale.

At the same time, the large amount of active oxygen generated by the processor further oxidizes the system pipe wall, forming a dense oxide film, such as the iron oxide film, which passivates the system pipe wall, thereby inhibiting pipeline corrosion, increasing the system's service life, and achieving the effect of equipment anti-corrosion.

Technical Parameter

Input power supply: 220V/380V, 50Hz Sterilization rate:> 99%

Working voltage: < 36V algae killing rate:> 97%

Applicable water temperature: 0 ℃~95 ℃ Corrosion rate: meets national standards

Head loss: 4~7m Applicable water quality: calculated as CaCO3

Scale removal and inhibition efficiency: 99% Total hardness: < 700mg/L

G-type (used for closed circulating water systems)


Specification and parameter table of G-type bypass flow processor

Selection area
External dimensions
Detailed dimensions
External connection size
head loss
m
Ideal power
w
weight
Kg
model
Model Diameter mm
Long L
mm
Width W
mm
High H
mm
A
mm
B
mm
C
mm
Import and export diameter mm
Discharge outlet diameter mm
YLD-‖-1G
80
900
560
1200
500
350
120
25*
25
0.2
≤50
100
YLD-‖-2G
100
900
560
1200
500
350
120
25*
25
0.4
≤90
100
YLD-‖-3G
150
900
560
1200
500
350
120
25*
25
0.7
≤120
102
YLD-‖-4G
200
900
560
1200
500
350
120
25*
25
1.0
≤160
110
YLD-‖-5G
250
900
560
1200
500
350
120
25*
25
1.0
≤220
110
YLD-‖-6G
300
900
560
1200
500
350
120
32*
25
1.0
≤300
115
YLD-‖-7G
350
900
560
1200
500
350
120
32*
25
1.0
≤500
120
YLD-‖-8G
400
900
560
1200
500
350
120
40*
25
1.0
≤600
130
YLD-‖-9G
450
950
580
1200
500
350
120
40*
25
1.0
≤800
160
YLD-‖-10G
500
950
580
1200
500
350
120
50
25
1.0
≤900
180
YLD-‖-11G
600
950
580
1200
500
350
120
50
25
1.0
≤1100
190
YLD-‖-12G
700
1000
1100
1200
500
350
120
65
25
1.0
≤1400
236
YLD-‖-13G
800
1000
1100
1200
500
350
120
65
25
1.0
≤1700
250

Note: The applicable pipe diameter refers to the diameter * of the closed system main pipe suitable for this model of water processor, which is indicated as a threaded connection, while others are flange connections
F-type (for open cooling water systems)



Specification and parameter table of F-type bypass flow processor

Selection area
External dimensions
Detailed dimensions
External connection size
head loss
m
Ideal power
w
weight
Kg
model
Model Diameter mm
Long L
mm
Width W
mm
High H
mm
A
mm
B
mm
C
mm
D
mm
E
mm
F
mm
Import and export diameter
mm
Discharge outlet diameter
mm
YLD-‖-1 F
80
1100
600
1300
620
350
590
440
310
180
25*
25
6
≤90
160
YLD-‖-2 F
100
1100
600
1300
620
350
590
440
310
180
25*
25
6
≤120
160
YLD-‖-3 F
150
1100
600
1300
620
350
590
440
310
180
25*
25
6
≤160
165
YLD-‖-4 F
200
1100
600
1300
620
350
590
440
310
180
25*
25
6
≤200
170
YLD-‖-5 F
250
1100
600
1300
620
350
590
440
310
180
25*
25
6
≤300
172
YLD-‖-6 F
300
1100
650
1300
620
350
590
440
310
180
32*
25
4
≤500
180
YLD-‖-7 F
350
1100
650
1300
620
350
590
440
310
180
32*
25
7
≤600
180
YLD-‖-8 F
400
1200
720
1400
630
350
590
440
310
180
40*
25
5
≤800
185
YLD-‖-9 F
450
1200
720
1400
630
350
590
440
310
180
40*
25
7
≤900
186
YLD-‖-10 F
500
1300
730
1400
640
365
590
440
310
180
50
25
4.5
≤1100
190
YLD-‖-11 F
600
1300
730
1400
640
365
590
440
310
180
50
25
5
≤1300
195
YLD-‖-12 F
700
1400
740
1400
850
395
590
440
310
180
65
25
4
≤1500
198
YLD-‖-13 F
800
1400
740
1400
850
395
590
440
310
180
65
25
5
≤1800
200

Note: The applicable pipe diameter refers to the diameter of the open system main pipe that this model of water processor is suitable for. * is represented as a threaded connection, and others are flange connections

Selection of YLD-II Side Stream Processor
A、 The open cooling water system should choose F-type, and select the water processor according to the pipe diameter indicated by the F-type specification.
B、 The closed circulating water system should be selected as G-type, and the water processor should be selected according to the pipe diameter indicated by the G-type specification.

Design and Installation of YLD-II Side Stream Processor
The design working pressure of YLD-II bypass flow processor is 1.0Mpa, and customers with special requirements can make special designs according to actual situations. When designing and installing, space should be reserved around the system water pump for the installation of the processor. The inlet of the processor should be connected to the outlet pipe of the system water pump, and the outlet of the processor should be connected to the inlet pipe of the system water pump (as shown in the installation diagram). The external power supply of the processor is a 220V/380V, 50Hz ordinary power supply, and the processor is installed indoors in a dry and ventilated area.
The new system can directly install the processor. For old systems with severe scaling, the pipeline must be cleaned before installing the processor to avoid blockage of the pipeline by falling scale.
YLD-II Side Flow Processor After sales Service
Our company's products undergo strict technical testing before leaving the factory to ensure that each device is a qualified product. Our company provides free repair within one year and lifelong maintenance for the products sold. If the equipment malfunctions during operation, our company guarantees to provide a response within 48 hours.

Explosion proof bypass flow processor

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!