Testomat 2000PO4 online phosphate analyzer
HEYL online phosphate analyzer from Germany
Performance characteristics:
- By selecting reagents and measuring ranges
• Simple menu driver program, text display programming
• High precision titration with piston metering pump
• Analysis startup: - Automatic interval operation (set interval of 0-99 minutes)
External control - Dynamic mode (depending on the range of device power consumption) - Flow control through water meter
Monitor two measurement points (via external valves)
Internal error records
• Programmable maintenance interval
500ml reagent bottle, available for operation
• Optional data recording device (with SD card), or port card (0/4-20mA), or RS 232
Technical parameters:
measuring method |
spectrophotometry |
measuring range |
Determine based on the selection of reagents |
Measurement method |
Timed measurement, quantitative measurement, external control |
output |
Two sets of programmable setpoints, alarm output points for cleaning the measuring tank or replenishing medication, 4-20mA signal or RS232 interface |
Relay contact capacity: |
4 A |
Inlet water pressure |
0.1 - 8 bar |
Inlet water temperature |
10 - 40 °C |
display |
lcd display |
protection grade |
IP 65 |
power |
Maximum 30VA |
power supply |
230 V or 24 V |
Dimensions (W x H x D) |
380 x 480 x 280 mm |
weight |
9.5 kg |
Reference for other models of Testomat 2000 analyzer
Serial Number |
order No |
model |
notes |
|
TESTOMAT analyzer |
||||
1 |
100122 |
TESTOMAT ® ECO |
Test the hardness of water quality |
|
2 |
100096 |
TESTOMAT ® two thousand |
Similar to Testomat ECO |
|
3 |
100704 |
TESTOMAT ® EVO |
Similar to Testomat ECO |
|
4 |
100301 |
TESTOMAT ® DUO |
Similar to Testomat 2000, TESTOMAT DUO allows the operation of two different types of reagents, if the function of "controlling samples from two different locations" is used. |
|
5 |
100221 |
TESTOMAT ® CAL |
Similar to Testomat 2000, adding calibration function |
|
6 |
100181 |
TESTOMAT ® V |
Online detection of total hardness, built-in positioning controller. |
|
7 |
100241 |
TESTOMAT ® CLF |
Online detection of free chlorine, in compliance with DPD method |
|
8 |
100141 |
TESTOMAT ® CLT |
Online detection of total chlorine, in compliance with DPD method |
|
9 |
100281 |
TESTOMAT ® THCL |
Composite equipment: online detection of total hardness and total chlorine (total chlorine meets DPD method) |
|
10 |
100161 |
TESTOMAT ® Fe |
Online detection of iron content for controlling iron removal |
|
11 |
100321 |
TESTOMAT ® CrVI |
Online detection of hexavalent chromium content for controlling the content of Cr6+in wastewater |
|
12 |
110121 |
TITROMAT ® TH |
Online titration detection of total hardness, using 2 reagents -Hardness up to 896 ppm -There is a particularly high resolution in soft water control |
|
Optional accessories |
||||
13 |
270305 |
SK910(6)0/4-20mA |
4-20mA current output module |
|
14 |
270310 |
RS 910 RS 232 |
RS 232 module |
|
15 |
130010 |
R 230V 50Hz |
CO2 removal device |
|
reagent |
||||
20 |
152005 |
TH 2005 |
500 ml |
2000/ECO |
21 |
152025 |
TH 2100 |
500 ml |
2000/ECO |
22 |
152100 |
TH 2250 |
500 ml |
2000/ECO |
23 |
152250 |
TH 2050 |
500 ml |
2000/ECO |
24 |
153050 |
TC 2050 |
500 ml |
2000/ECO |
25 |
154005 |
TM 2005 |
500 ml |
2000/ECO |
26 |
155100 |
TP 2100 |
500 ml |
2000/ECO |
27 |
155160 |
TH 2500 A |
500 ml |
TITROMAT ® TH |
28 |
155161 |
TH 2500 B |
500 ml |
TITROMAT ® TH |
35 |
156220 |
CrVI 2100 A |
500 ml |
TESTOMAT ® CrVI |
36 |
156221 |
CrVI 2100 A |
500 ml |
TESTOMAT ® CrVI |
37 |
156250 |
Fe 2005 A |
500 ml |
TESTOMAT ® Fe |
38 |
156251 |
Fe 2005 B |
500 ml |
TESTOMAT ® Fe |