Ø Main Features:
l Large screen dot matrix LCD 192 × 64 (or 320 × 240), multi parameter display, rich content.
l The adoption of advanced embedded system design and surface mount technology has improved
Performance and reliability, compliance with EMC design requirements
l Fully guided operation mode in both Chinese and English, easy to use, and easy to understand.
l Programmable automatic or manual temperature compensation method, flexible and convenient to use.
l Two completely isolated current signals can be output, and the output current range can be set separately.
l Equipped with upper and lower limit alarm functions, the alarm values can be set separately.
l Equipped with a standard 485 digital communication interface, it can achieve long-distance communication.
l It has the functions of storing and querying historical data, operation and calibration records.
l Can query 100000 historical data, 1000 operational records, and 100 calibration records.
l High protection level, reaching IP66, can meet various complex environmental requirements.
l The electrode zero drift is small and the response speed is fast.
l The residual current of the electrode is small, the maintenance is simple, the service life is long, the structure is firm, and the anti pollution ability is strong.
l Equipped with polarization voltage scanning function, it can automatically complete electrode self diagnosis.
Ø Main Technical Performance:
Display: Chinese display, 192 × 64 (or 320 × 240) dot matrix LCD
Range: (0-20) µ g/L, (0-200) µ g/L, (0-20) mg/L (automatic shift)
Resolution: 0.1 µ g/L; 0.01 mg/L;
Basic error:<± 1.5% F.S or 1 µ g/L (whichever is greater)
Response time: 90% change achieved within 60 seconds at 25 ℃
Temperature sensor: thermistor
Temperature measurement range: 0.0~99.9 ℃
Temperature measurement accuracy: ± 0.5 ℃
Temperature measurement resolution: 0.1 ℃
Temperature compensation range: 0-50 ℃ (manual or automatic)
Sample conditions: Temperature range: 5-50 ℃
Flow range: 50-300ml/min (optimal around 150ml/min)
Allowable solid content of water sample: ≤ 5 microns (no gelatinous substances allowed, no oil or grease)
Environmental temperature: 5-45 ℃
Environmental humidity: ≤ 90% RH (no condensation)
Output current: (4-20) mA (two-way isolated output)
Current accuracy: ± 1% FS
Current load:<800 Ω
Power supply: AC (85-265) V, frequency (50-60) Hz
Power: ≤ 10W
Alarm output: Two channel alarm output, DC 5A/30V or 5A/250V
Storage and transportation temperature: (-20~55) ℃
Dimensions: 144mm x 144mm x 210mm (width x height x depth)
Disk mounting hole size: 139mm × 139mm
Weight: Approximately 1.5kg