Gopu Instrument (Shanghai) Co., Ltd
Home>Products>Online analyzer for residual chlorine and total chlorine in drinking water
Online analyzer for residual chlorine and total chlorine in drinking water
Brief description: The PROCON 3000 online analyzer for residual chlorine and total chlorine in drinking water is used to detect and control chlorine c
Product details

Online analyzer for residual chlorine and total chlorine in drinking waterPROCON 3000


Online analyzer for residual chlorine and total chlorine in drinking waterPROCON 3000Mainly composed of a control unit with a touch screen and a measurement room The analysis unit consists of valves, metering pumps, and pipelines. Control with microprocessor Control the automatic operation of the entire analysis process by the manufacturing unit, including automatic sampling and automatic Cleaning, pumping reagents and photometric testing.The PROCON3000 analyzer can measure residual chlorine or total chlorine by selecting different reagents. Typically used for detecting chlorine content in water bodies such as drinking water, cooling water, and swimming pool water.


PROCON3000 analyzerMeasurement parameters:

Measurement parameters

Residual chlorine or total chlorine

measuring range

0.02-2.00ppm CI2

resolution

0.1ppm

refined linear measure

2% final value

repeatability

1% final value

zero stability

Automatic adjustment

Analysis cycle

3-5 minutes without rinsing time

between partition

1min-99min or external start stop

current output

0/4_20mA, Load 500Q

apparent show

240x128, Touch Screen

operation temperature

5-45. (The reagent needs to be used up within 6 months)

Electrical connection

1.5mm2Circular plug connection

relay

1x alarm, passive 230v/50Hz, 3A; 1x limit, passive 230v/50Hz, 3A; 1 x analysis of pancreas, approaching 230v/filter, 3A

Remote control

Passive, 18VDC, ca.4mA

supply voltage

110-230V(50/60Hz)

ability consume

Approximately 16VA

chi cun

640x315x190mm(HxWxD)

protection grade

IP65



sample

Working pressure

0.1-10bar

temperature


5-30^

Sample Volume


25ml/per analysis (excluding cleaning)

Sample conditions


Clear, filtered

Chemical Conditions


pH4-8

emission


Non pressure open type

reagent

quantity


2

model

CL1001/CL1002 (residual chlorine) CL1001/CL1003 (total chlorine)

storage temperature


5-25^

Single analysis consumption

0.27ml/analysis

Total Volume


250ml/250ml

Analysis frequency


925


图片.png

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!