GC1120Non methane total hydrocarbon detection gas chromatographycharacteristic
More outstanding instrument performance
GC1120Yes, it isThe new gas chromatography developed on the basis of GC112A not only upholds the many qualities of GC112A, but also provides more advanced, precise, and higher technical specifications for ordinary functions.
Clear display screen at a glance
Large screen display, realizing Chinese menu style dialogue, making the display clearer and the operation simpler. It can display chromatograms, rise curves, and baseline levels, and simultaneously display the temperature settings and actual values of column boxes, injectors, detectors, etc. on one screen, providing more diverse and colorful instrument information.
Digital carrier gas flow monitoring system
The GC1120 pneumatic system can be equipped with an optional digital flow monitoring unit that displays the carrier gas flow rate and capillary branch flow rate values on the screen. It can display up to four sets of flow rates and automatically store flow parameters for easy recording and retrieval of analysis conditions. Convenient diversion adjustment and diversion ratio calculation, no need to use soap film flowmeter
Rich combinations of injector/detector units
Better expansion configuration to meet various needs. Choose more injector/detector series based on the diversity and complexity of the analyzed samples.
GC1120Four types of injectors can be configured from packed column injection unit, capillary split/non split injection unit, and up to three injectors can be loaded simultaneously.
GC1120Up to 6 high-performance detector options are available, including FID, TCD, ECD, FPD, NPD, and PID, and up to 3 detectors can be installed simultaneously. Additional detectors can also be used, making it easy to purchase and install other detectors after purchasing the instrument.
New built-in acquisition system
GC1120Advanced built-in acquisition device can collect instrument control status and chromatographic output signals, enabling real-time instrument control and data processing by connecting an external computer with a communication cable.
Real time control of instruments includes functions such as temperature control of various channels, selection and setting of detectors, programmed temperature rise control and range curve tracking, flow value display (optional), etc.
Data processing includes high-speed acquisition of dual channel (expandable to multiple channels) chromatographic data, automatic or manual setting of integration parameters, up to 5 quantitative methods, baseline deduction, report preparation, and other functions.
GC1120Non methane total hydrocarbon detection gas chromatographySpecification parameters
| specifications | Main configuration |
| GC1120-1 | Capillary injection system (including diaphragm blowing, back pressure valve diversion) tail blowing adjustment FID |
| GC1120-2 | Double packed column injection system TCD |
| GC1120-3 | Double filled column injection system with dual FID |
| GC1120-4 | Single packed column injection system, independent capillary injection system (including diaphragm blowing, back pressure valve diversion), tail blowing adjustment, dual FID |
| GC1120-5 | Dual packed column injection system, independent capillary injection system (including diaphragm blowing and back pressure valve diversion), tail blowing adjustment, dual FID |
| GC1120-6 | Dual independent capillary injector system (including carrier gas control, diaphragm blowing, back pressure valve diversion, independent temperature control), dual tail blowing adjustment, dual FID packed column injection accessories (modified on the capillary injector) |
Note: The above are common configurations, and users can make any configuration combination according to their special needs. Please specify when placing an order.
GC1120Main technical indicators
temperature control
Temperature control range: 7 ℃ above room temperature~400℃(Increment 1 ℃)
Temperature control objects: column box, detector, thermal conductivity cell, sampler, auxiliary
Cheng Sheng order: Eight orders
Cheng Sheng rate: 0.1 ℃~40℃/min (Incremental 0.1 ℃)
Constant temperature time: 0~655min (Increment of 1 minute)
Flame photometric detector(FPD)
Detection limit: ≤1×10-11g/s(P)
Sample:
≤1×10-10g/s(S)
Sample:
Hydrogen flame ionization detector (FID)
Sensitivity: M ≤ 8 × 10-12g/s Sample: C16
*Test result: M ≤ 3 × 10-12g/s Sample: C16
Nitrogen phosphorus detector (NPD)
Detection limit: ≤5×10-12g/s(N)
Sample: Azobenzene
≤5×10-13g/s(P)
Sample:
Thermal conductivity detector (TCD)
Sensitivity: ≥ 5000mV · mL/mg Sample: C16
Zui high sensitivity: ≥ 10000mV · mL/mg (optional electronic amplifier board)
Electron Capture Detector (ECD)
Detection limit: ≤ 1 × 10-13g/ml Sample: γ -666
Maximum operating temperature: 350 ℃
Photoionization detector (PID)
Detection limit: ≤ 1pppb
Sample: Benzene
| main accessories | Function Introduction |
| GC1120-TCD Thermal Conductivity Detector | High quality rhenium tungsten wire, controlled by a constant current source, balanced with dual packed columns, and equipped with an amplifier. |
| GC1120-FPD flame photometric detector | Double flame structure, optical fiber signal transmission, with high response values for trace amounts of phosphorus and sulfur organic compounds. |
| GC1120-ECD electron capture detector | Using NI63 radioactive source, it has extremely high sensitivity to substances with strong electronegativity, such as halogen compounds. |
| GC1120-NPD nitrogen and phosphorus detector | Using imported high stability rubidium beads, it has a high response value for organic compounds containing nitrogen and phosphorus. |
| GC1120-PID photoelectric ion detector | Non destructive detection, using photons to ionize the sample, without a radioactive source, theoretically capable of detecting all gas (vapor) compounds with ionization potentials below 10.6eV |
| Digital traffic monitoring module | Each module can collect air flow values and connect to the motherboard to achieve real-time digital display of flow |
| Capillary Split/Non Split Injection System | Capillary splitter/non splitter injector, capable of independent temperature control, independent gas path (including carrier gas control, diaphragm blowing, back pressure valve splitting), tail blowing adjustment, inlet cleaning solenoid valve, and time program control for split/non split injection. |
| Liquid automatic sampler | Realize automatic injection of chromatographic liquid samples, with up to 110 sample positions in the sample tray. |
| Headspace sampler | The sample is sealed in a sample bottle and heated for a certain period of time to analyze the headspace gas in the gas phase. Suitable for volatile component analysis of solids and liquids. |
| Thermal analyzer | The sample air is introduced into the adsorption tube, and the volatile components are retained in the adsorption tube. Heat the adsorption tube to desorb the collected vapor (volatile organic compounds), and the sample to be tested enters the chromatograph with an inert carrier gas for analysis. |
| simulation software | Simulate the search for chromatographic conditions for chromatographic simulation teaching, training, and knowledge base access. |