Multi parameter/multifunctional water quality analyzer
Instrument description: The multi parameter water quality rapid measuring instrument adopts a 5-inch high-definition screen, flat icon design, guided
Product details

Instrument Introduction

The YC-8100 multi parameter/multi-functional water quality rapid measuring instrument is designed and developed based on relevant national standards. It adopts an independent multi module optical (imported) design with excellent optical performance,5A high-definition color screen with a flat icon design, a guided operating system, and a simple and easy to understand interface, allowing operators to use it quickly and accurately.


Measuring Item


Serial Number

Measuring Item

Measurement range(mg/L

limit of detection

Serial Number

Measuring Item

Measurement range(mg/L

limit of detection

1

COD

0-10000

5

17

manganese

05

0.04

2

Mn methodCOD

0-10

0.1

18

phosphate

0-20

0.02

3

Ammonia nitrogen

0-50

0.05

19

sulfate

0-200

5

4

total phosphorus

0-20

0.02

20

sulfide

0-4mg/L

0.01

5

total nitrogen

0-100

0.5

21

cyanide

0-1

0.004

6

turbidity

0-1000NTU

0.5

22

fluoride

0-10

0.02

7

Suspended solids(SS

0-500

5

23

nitrate nitrogen

0-20

0.5

8

chroma

0-500linear measure

5

24

nitrite

0-1

0.002

9

hexavalent chromium

0-5

0.01

25

Residual chlorine

0-10

0.1

10

chromium

0-5

0.01

26

total chlorine

0-10

0.1

11

copper

0-50

0.05

27

chlorine dioxide

0-10

0.05

12

nickel

0-4

0.1

28

silica

0-5

0.1

13

zinc

0-15

0.05

29

Volatile phenol

10

0.1

14

iron

0-50

0.01

30

arsenic

0-0.5

0.005

15

silver

0-1

0.05

31

aniline

0-2

0.02

16

antimony

0-10

0.5

32

…………….




Host technical parameters


Measurement Error

≤± 5

Optical stability

≤±0.001A/20Minutes(100000Hour without decay)

transmission mode

USBLocal Area Network

display

5Inch high-definition color screen

repeatability

≤±3%

Colorimetric method

Colorimetric tube (digestion colorimetric integrated tube)

Printing method

Built in thermal printer

Operation interface

Chinese/English (optional)

Storage

3Ten thousand records96Curve (supports customization)

work environment

5-45 85%No condensation

Host size

348mm*250mm*145mm

Instrument weight

host<2.6kg; Dissolver<7kg

Power supply mode

AC(220V±10%)50Hz

power

5W


Technical parameters of digestion instrument

Dissolve sample size

25branch

time display

Real time date and time display

Operation interface

Chinese display

operating mode

Touch-tone

rated voltage

AC 220V±10%/50Hz

Power requirements

grounding

Dissolve pore size/depth

16mm/65mm

Dissolving capacity

>12mL

display screen

TFTHigh definition color screen

timing error

10min±0.1s

Pre set digestion mode

COD、 Total phosphorus and total nitrogen

Dissolution method

Fully enclosed type

safety protection

Double protection against overheating

temperature control

intelligencePIDtemperature control

custom mode

5, temperature and time can be set arbitrarily

Project switching

Quick switch

Reminder method

buzzer

Alarm prompt1

Reaching the specified temperature and maintaining a constant temperature

Custom time

5-999min adjustable

Alarm prompt2

Dissolve completed and stop heating

Custom Temperature

90~200 ℃ adjustable

Dissolve protection

Heat shield/shield

Temp Accuracy

0.5

Temperature control sensor

Imported PlatinumPT100

heating rate

Set to165℃,12Constant within minutes

Instrument weight

6kg

work environment

-10-40 ℃, relative humidity<85%

External dimensions

230*340*130mm


Instrument characteristics

1. High definition color design:5Inch high-definition screen, supports medium resolution/English display (optional), guided operating system, simple and time-saving.

2. Wide detection range: dozens of detection parameters can be expanded, and customized according to customer needs.

3. Detection optics: Adopting independent multi module optical (imported) design, excellent optical performance, stable and reliable.

4. Operating System: Guided operating system with a simple and easy to understand interface, guiding users to complete operations quickly and accurately.

5. Operating procedure:a.Built in system program and user program, which can add frequently tested items to the user program for easy searching.

b. It has power-off protection function and one click factory reset function to prevent data loss.

c. The built-in standard work program can be used directly, and users can also expand the detection items themselves.

d. Built in help interface, which can query user detection process problems and issues.

e. It has a one click factory reset function, which can quickly recover data loss in case of unexpected situations.

6. Intelligent detection: Standard measurement and continuous measurement can be switched freely, reducing repeated measurement steps and improving detection efficiency.

7. Operation safety: Adopting a digestion colorimetric integrated tube, reducing the steps of transferring reagents, making the measurement simple, fast, and safe.

8. Quick printing: Equipped with a built-in thermal printer, it can print both current and historical measurement data.

9. Data storage: standard working curve and96User defined projects that can be stored30000Strip detection data.

10. Online function: supports network ports, local area networksUSBgivePCEnd or printer for data transmission.

11. Professional reagents: specialized reagents, simplified operating procedures, reduced operational errors, less reagent usage, and lower consumable prices.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!