Multi functional power meters suitable for hospital use
Every hospital needs a monitoring system, whether private or public, such as security monitoring in outpatient and inpatient buildings, 24-hour monitoring of patients in wards and monitoring rooms, surgical observation and learning in operating rooms, joint consultations with doctors, and real-time monitoring of each surgery and patient in each ward as much as possible, which is conducive to standardized management of the hospital. To choose this monitoring system, it is necessary to configure multifunctional power metersWhat are the multifunctional power meters suitable for use in hospitals? The multifunctional power meter expert from Xiamen Johnson recommends to you the products produced by our company:
PMS963M color screen multifunctional power meter (96 * 96)
Why do we recommend this product from our company? Click on some product details to view the reason:PMS963M color screen multifunctional power meter (96 * 96)
Meanwhile,Jiangxi Provincial People's Hospital has also selected the products produced by our companyEstablish a monitoring system for hospitals using a series of multifunctional power meter products!

operation parameters
Working power supply: 85VAC~265VAC/85VDC~265VDC, power consumption<>
Analog sampling rate: 64 points per cycle
Supporting wiring methods: three-phase four wire system 3CT, 1CT and three-phase three wire system 3CT, 2CT, 1CT
RS485 communication: Supports Modbus protocol, communication rate (60012002400480096019200), maximum node capacity of 32
Communication response time: 20ms (9600bps)
Operating environment: -20 ℃~60 ℃
Humidity: 95% without condensation
Insulation complies with DL478, vibration complies with GB7261-87, and anti-interference complies with GB6162
Protection level: Panel IP54, Shell IP20
Weight: 0.5Kg
Tracking frequency range: 45~65Hz (resolution: 0.02Hz)
Accuracy: The acquisition part (U, I) is at level 0.2, and the calculation part (P, Q, S) is at level 0.5; (Please specify when ordering at level 0.2)
PT frequency input: 220V on the secondary side or standard 100V (input continuously overloaded to 1.25 times the rated value)
Primary side 100V~35000V
CT rated input: 5A/1A (continuously overloaded to twice the rated value), (indicate the required type when ordering)
External dimensions
Type 96: Frame (mm): 96 * 96 Hole (mm) 91 * 91 Depth (mm) 78
Parameter function
Basic functions: three-phase I, U, Kw, Kvar, Kwh, Kvar, Hz, cos φ, RS485/Modbus, color screen LED display
Extended functions: 4DI (K), 2DO (O), 2AO (M), 2-channel pulse (P)
Compliant with standards
GB/T 13729_2002 Remote Terminal Equipment
IEC61000-4-2:1995 Electrostatic discharge immunity test level 3
IEC61000-4-4:1995 Electrical fast transient burst immunity test level 3
IEC61000-4-5:1995 Surge Immunity Test Level 3