Jiangsu Jiamei Instrument Manufacturing Co., Ltd
Home>Products>Multi functional blood plasma analyzer
Multi functional blood plasma analyzer
A new type of multifunctional blood plasma analyzer has been independently developed to meet the needs of hospital blood banks. The machine adopts dig
Product details

Detailed information of JMR-8 multifunctional blood plasma analyzer:



Multi functional blood plasma analyzerWe have independently developed a new multifunctional plasma dissolving machine to meet the needs of hospital blood banks. This machine adopts digital display and computer temperature control. The temperature can be set arbitrarily according to different needs, and the water temperature difference is not greater than ±1℃, equipped with an automatic swing system that can automatically adjust the frequency, especially for dissolving plasma. Dissolve and shake simultaneously, take out in a few minutes and use. Reducing the number of procedures, saving time for rescuing patients, and facilitating medical workers, it is an ideal supporting tool for blood banks.

  • Multi functional blood plasma analyzerMain technical parameters:
  1. Temperature control:37℃±0.5
  2. Temperature control accuracy: ±0.5
  3. Digital temperature display, microcomputer temperature control.
  4. Heating power: ≤1000W
  5. Thawing time: ≤10min
  6. The maximum slurry volume is less than8Bag(100-200ml
  7. Non movable stainless steel thawing blue8only
  8. Equipped with an automatic back and forth swing system80order/Minute or automatic frequency modulation.

  • matters needing attention:
  1. Normally set the water temperature, it can be turned on for a long time. When in use, turn on the swing switch, set the frequency, and it will automatically swing. Turn off the swing switch after use to save electricity and reduce mechanical wear and tear.
  2. Before use, be sure to add water to the desired level and avoid dry burning to protect the heating tube. As the startup time increases, the water in the water tank will gradually evaporate. Please check the water level at any time (add water and replace it). Ensure that the machine is operating normally. 、
  3. Set temperature: PressSETThe key can be used to set or view the temperature setpoint. clickSETThe key tube symbol starts flashing, indicating that the instrument has entered the set state. Press the △ key to increase the set value, and press the △ or ▽ key to quickly change the data. Press againSETThe key instrument panel returns to normal working state and the temperature setting is completed. The heating start indicator light is on.
  4. Pre setting: PressSETkey3The second meter enters the inner parameter setting state. *The parameter that appears and flashes is the advance amount that stops immediately. The advance amount parameter should be carefully adjusted to reduce temperature overshoot. When the instrument controls the heating output, it will cut off heating in advance. When the temperature drops below the advance amount, it will start heating again. The output (relay) will not work within the set value and advance amount range. This can reduce the number of relay actions to extend the service life of the relay. Example: If the set value is50.0℃, with an advance amount of0.5The instrument controls the heating to49.50When the relay is released, the temperature drops to50.0℃-0.5=49.5At ℃, the relay closes again. The larger the advance amount, the fewer times the relay will act, and if the advance amount is too large, it will reduce the control accuracy. After adjusting the advance quantity parameter, pressSETkey3The second meter returns to working mode. (Note: Pre setting is specifically set to prevent excessive temperature surge after heating stops, and generally does not require modification.)