characteristic:
-Adopting imported Honeywell PT100 temperature sensor for more precise temperature control
-Two control modes: fixed value and program
-Equipped with automatic start, automatic stop, timed operation, and clock display functions
-Door switch monitoring function
-Five level automatic defrosting function and manual defrosting function
-Logging function
-Fault monitoring, alarm, and recording functions
-Level 4 password function: login password, operator password, administrator password, advanced administrator password
-Three power failure mode selection functions: power failure recovery, stop or restart
-Curve display function
-GPRS SMS alarm function
-Real time data and historical data printing function
-Touch screen data storage function;
-Computer monitoring software monitoring function
-Equipped with temperature calibration function
-Water level monitoring and automatic water replenishment function (humidity control type)
effective volume | Touchscreen without humidity control series | Touch screen humidity control series |
150L | MI-150T | HMI-150T |
250L | MI-250T | HMI-250T |
450L | MI-450T | HMI-450T |
750L | MI-750T | HMI-750T |
1100L | MI-1100T | HMI-1100T |
temperature range | 0 degrees to 70 degrees | 0 degrees to 70 degrees |
Temperature display accuracy | 0.1 degrees | 0.1 degrees |
Humidity display accuracy | not have | 15~95% |
Humidity display accuracy | not have | ±2.5%RH |
Ultraviolet lamp | have | have |
Curve display function | have | have |
Data monitoring function | have | have |
Data storage function | have | have |
Level 4 password function | have | have |
Data storage function | have | have |
Fault monitoring, alarm, recording | have | have |
Temperature control method | Fuzzy Intelligence P.I.D | |
program control | Normal mode and program mode | |
Defrosting method | Level 5 automatic defrosting and manual defrosting | |
Frost free area | Frost free operation above 20 degrees Celsius | |
temperature sensor | Imported Honeywell PT100 | |
Three power outage mode selection functions | Power outage recovery, stopping or restarting | |
test hole | Double testing holes on both sides | |
Thermal insulation material | Polyurethane foam material | |
operation temperature | 5~35 ℃ (recommended for long-term operation, with ambient temperature below 30 ℃) | |
power supply | AC220V±10% 50HZ/60HZ |
Volume (liters) | 150L | 250L | 450L | 750L | 1100L |
Temperature uniformity (at 37 degrees) | ± 0.5 degrees | ± 0.5 degrees | ± 0.5 degrees | ± 1 degree | ± 1 degree |
Power | 500W | 750W | 800W | 1000W | 1000W |
Cooling Power | 1100W | 1500W | 2000W | 2500W | 3000W |
Inner container size (W * D * H) mm | 540*400*700 | 640*440*890 | 750*500*1200 | 1250*500*1200 | 1250*735*1200 |
Dimensions (W * D * H) mm | 700*830*1300 | 800*870*1470 | 910*930*1785 | 1410*950*1705 | 1410*1185*1705 |
Shelf (standard) | three layers | three layers | four layers | four layers | four layers |
Factory standard plug | 10A | 10A | 16A | 16A | 16A |
Product weight | About 96kg | About 117kg | About 186kg | Approximately 216kg | About 256kg |
-The testing technical data is only applicable to the test results under no-load conditions of the equipment and at an ambient temperature of 25 degrees Celsius!
-Product appearance and parameter changes will not be notified separately. The product appearance may deviate due to photography, printing, and other reasons. We apologize for any inconvenience caused!
-Printer
-GPRS mobile SMS alarm
-Computer monitoring software