Microwave power meter GX2BB01S
The GX2BB01S series microwave power meter is equipped with a built-in 50MHz calibration source to provide a power reference, which can calibrate the h
Product details
GX2BB01S Microwave Power Meter

1、 Overview

The GX2BB01S series microwave power meter is a new generation of detection diode power meter based on digital signal processing technology. It has a built-in 50MHz calibration source to provide power reference and can calibrate the host and power sensor. It has automatic calibration and zeroing, and 10 built-in storage/retrieval registers for users to store and call data;GX2BB01S series microwave power meterPaired with YS11801X series power sensors, it has the advantages of wide frequency range, large dynamic range of power measurement, fast measurement speed, and high measurement accuracy.

GX2BB01S series microwave power meterThe calibration of the power indicator and the measurement of power level can be completed manually through the front panel or controlled by the USB interface,And the back panelBNCInterface:420mASignal output.GX2BB01S series microwave power meterThe superior performance can fully meet the measurement of RF and microwave power in fields such as radar, communication, broadcasting and television.


2、 Microwave power measurement technology

In the DC and low-frequency fields, power measurement can be achieved by measuring voltage and current. However, when the signal frequency is in the tens of MHz or even hundreds of GHz range, traditional methods can no longer meet the needs of power measurement. Therefore, low-frequency measurement methods lose their own significance and are replaced by electromagnetic field theory. Microwave power meters are a good means to solve microwave power measurement.

The microwave power meter consists of two parts, the * * part is the power sensor (power probe), which directly determines the bandwidth and dynamic range of microwave power measurement** Part of it is a power indicator (referred to as a power meter), which is used to set and display the measurement method, menu functions, and power measurement results of the power meter.

Power unit:

The unit of power is generally represented by watts, with the symbol "W". It can also be derived from kilowatts, megawatts, milliwatts, microwatts, and other units, which are also common in the DC and low-frequency fields. There is another commonly used unit for power: decibel milliwatt (dBm)

It can be calculated according to the following formula:

A =10log( P/

P0) (dBm)

In the formula, P and P0 are symbols representing power, with the power unit being milliwatts (mW), where P0 is defined as a reference of 1mW

Power.

Example:

The power of 1mW is converted to 0 dBm using the above formula;

The power of 10mW is converted to 10 dBm using the above formula;

The power of 0.1mW, converted by the above formula, is -10 dBm;


The unit of dBm is a widely used power unit in the microwave field.

3、 Technical specifications of microwave power meter

Frequency range10MHz ~ 18GHz(Depending on the power sensor configuration

)

power range

-50dBm ~ +20dBm

Zero setting±

10nW

display resolutionThe logarithmic method is

1-0.01dB50MHz/1mW

Power calibration sourcePower accuracy ±

2%

temperature range0 ~ 40

Storage temperature-40 ~ 70

330External dimensions260××

105mm

weightmake an appointment


3.5kg

4、 Main technical indicators of power sensors

model

YS11801A

YS11801B

YS11801C

Frequency range10MHz

12.4 GHz10MHz

18 GHz10MHz

18 GHz

power range-40dBm

+20dBm-40dBm

+20dBm-50dBm

+20dBm

*High power

+23 dBm

+23 dBm

+23 dBm

Power linearity-20dBm

+20dBm±

0.21dBm/10dBOther ±

0.09dB/10dB-20dBm

+20dBm±

0.21dBm/10dBOther ±

0.09dB/10dB-20dBm

+20dBm±

0.21dBm/10dBOther ±

0.09dB/10dB

VSWR1.29

Full frequency band less than or equal to1.29

Full frequency band less than or equal to1.29

Full frequency band less than or equal to

Input connector form

N(M)

N(M)

N(M)

temperature range0 ~ 40

0 ~ 40

0 ~ 40

Storage temperature-40 ~ 70

-40 ~ 70

-40 ~ 70

Dimensions (excluding wire length)

weightmake an appointment

0.4kgmake an appointment

0.4kgmake an appointment

0.4kg

Note: The power meter is matched with a power sensor and equipped with our company's precision attenuator, which can be extended to a series of medium to high power testers*itsHigh power can reach1W2W10W100W200W300W


...... Wait.

5、 Control Description and Function Key Introduction

5.1 Control Description (as shown below)

5.2 Function Introduction

Panel Introduction

function1

)Power switch

Used to turn on and off the use of this instrument.2LED

liquid crystal display

Used to set and display the measurement method, menu status, and power measurement results of the power meter.3

)Keyboard

Set and determine the measurement mode of the power meter, store and call the setting results. (The specific introduction of function keys is shown in the table below).4

)Power referencepass throughNType connector outputs one1mW0dBm50MHz

The reference signal is used to calibrate the probe and host system. When the LED next to the connector lights up, it indicates that the reference source is turned on.5

)Sensor interface

Power sensor access point6USB

interfaceUSB

The interface completes the calibration of the power indicator and the measurement of power level through remote control operation.7

)Socket fuse

Used to protect instruments8

)Power plugAC 95220V 45

55Hz9BNC

4interface20mA



output

keyboard

functionZERO

This keyboard has zero adjustment function. Press this key to enter the zero adjustment menuCAL

This keyboard is for calibration function. Press this key to enter the calibration menuMENU

This keyboard is a menu key, press this key to enter its * * submenu. And menu selection can be made through the 【 ▲▼ 】 keys to be introduced later.

The submenu includes:AVERAGE】【OFFSET】【FREQUENCY】【dBm/dBr】【SAVE】【CALL】【POWER REF

dBm/Watt

Used to switch display between logarithmic and watt modes◄►

】▲▼The directional keys are used to select and change parameters;

**Function keysENTER



Used to confirm the setting results

6、 Accessories List: box one1auxiliary word for ordinal numbers1Zhang, in total

fix

Microwave power meter one

position number

measureGX2BB01S

Series power meter host

1

tower

power sensor

1

individual attach

piece one

position number

measure

power line

1

root

fuse

1

individual

Technical manual

1

stem or root of plants

Product Qualification Certificate

1



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!