Mettler pH electrode InPro 2000 150/PT1000/9848
InPro 2000 150/PT1000/9848
Simulation or ISM | Analog |
Measurement parameters | pH |
PH glass film type | High Alkali glass (HA) |
Single liquid connection or double liquid connection | Single Junction Refillable |
sensor length | 150 mm |
temperature signal | PT1000 |
Type of connector | VP |
Solution grounding/redox metal | None |
electrolyte | Friscolyt |
pH range | 0-14 pH |
Pressure (bar) | 0 to 6 barg (in presurized housing) |
Pressure (psi) | 0 to 87 psig (in presurized housing) |
reference system | Argenthal with silver-ion trap |
disinfectant | Yes |
High voltage resistance | Yes |
membrane | Ceramic |
ATEX certificate | SEV 14 ATEX 0168 X<br> Ex ia IIC T6/T5/T4/T3 Ga/Gb |
FM Approval | IS/ I, II, III /1/ABCDEFG /T6 |
IECEx certificate | IECEx SEV 14.0025X<br> Ex ia IIC T6/T5/T4/T3 Ga/Gb |
Measurement temperature range (imp) | 32 to 284° F |
Measurement temperature range (index) | 0 to 140° C |
Material number (s) | 52001749 |
Mettler pH electrode InPro 2000 150/PT1000/9848
9848: Suitable for biochemistry, media containing proteins, organic solvents, and low temperatures
9816: Suitable for chemical processes, slow electrolyte flow rate 9830: Suitable for media containing a large amount of organic solvents 9823: Classic electrolyte, fast electrolyte flow rate, helps with membrane cleaning
Long service life under extreme conditions
PH electrodes that can be filled are highly suitable for extreme conditions. These sensors have a pressure resistant sheath and can be used in extreme applications where other sensors cannot be used. If properly maintained, these sensors can provide significant savings in electrode replacement. The unique silver ion capture trap can prevent electrode poisoning caused by sulfides, and the function of refilling the electrolyte means that the sensor can be used for many years.
Tailored performance for your application
The pH electrode that can be filled provides you with the ability to choose a specific reference electrolyte that suits your application needs. KCI electrolyte provides high permeability, which can improve membrane cleaning. Viscolyt has lower exudation, thus prolonging the refill interval. Calcolyt can be used in applications where there is a risk of calcium carbonate precipitation. The correct electrolyte means better accuracy and reliability in pH measurement.
Accurate and reproducible pH measurement
The pH electrode with refillable electrolyte provides various functions to ensure measurement accuracy. This series of pH sensors provides a pressure resistant reference system to ensure continuous self-cleaning of the diaphragm. Some models include an integrated temperature sensor that can achieve automatic temperature compensation. These features all help ensure consistent and accurate measurements.