◆ Product Introduction◆ Product IntroductionThe MKP series mold temperature control machine is mainly used for controlling the temperature of extrusion system rollers or plastic injection molds. It adopts imported high-temperature water (oil) pumps and temperature control components, with unique heating and cooling system designs, fast heating and cooling, making it an ideal choice for controlling roller barrel temperature and mold temperature.MKP series mold temperature controller is mainly used for the control of roller barrel of extrusion system or plastic injection mold temperature. It adopts the imported high-temperature water (oil) pump and temperature control components, and the unique heating system and cooling system design, with heating rapidly and cooling quickly, and is the ideal choice for the control of roller barrel temperature and mold temperature.◆ Characteristics◆ Characteristics◆ Fast heating and cooling;◆ Heating rapidly and cooling quickly;◆ Adopting imported PID intelligent temperature controller with high temperature control accuracy;◆ Use imported PID intelligent temperature controller with high precision of temperature control;Unique dual group low-density stainless steel electric heating tube with long service life;◆ Unique double low density stainless steel tubular electric heating element with long service life;Imported thermal circulation pumps and solenoid valves work stably and reliably;◆ The operation of imported thermal circulating pump and solenoid valve is stable and reliable;◆ It has multiple protection functions to ensure the safe operation of the machine;◆ Having multiple protection functions to ensure the safe opreation of the machine;The product has been carefully designed, with a beautiful appearance that conforms to the human-machine relationship.◆ The products have been meticulously designed and have beautiful apperance, and meet human-machine relationship.MKP series temperature control machine specification parameter table (1)
MKP Series Temperature Controller Specification Parameters Table (Ⅰ)
MKPSpecification and parameter table of series temperature control machine(one)
model |
MKP06S |
MKP09S |
MKP18S |
||
control system |
Temperature control range ℃ |
0~120 |
|||
Temperature controller accuracy |
1 |
||||
Operating Procedure ℃ |
Fuji, JapanPIDIntelligent Temperature Operating System |
||||
heating systemkW |
heating powerkW |
6(3×2) |
9(4.5×2) |
18(9×2) |
|
Electric heating material |
KANTHALAlloy electric heating wire and stainless steel electric heating tube |
||||
Electric heating densityw/cm |
12 |
12 |
12 |
||
Heating efficiency ℃/min |
16/2 |
16/2 |
16/2 |
||
heat exchanger |
Multi barrel style |
||||
energy output |
Adjustable automatically or manually |
||||
cooling system |
cooling method |
Direct cooling |
|||
Cooling efficiency ℃ |
30/1 |
30/1 |
30/1 |
||
heat exchanger |
Efficient shell and tube type |
||||
Electromagnetic valve diameter |
3/8” |
3/8” |
1/2” |
||
circulatory system |
pump powerkW |
0.37 |
0.75 |
2.20 |
|
maximum flowL/min |
65 |
120 |
220 |
||
maximum pressureMPa |
0.3 |
0.3 |
0.4 |
||
Security protection system |
Motor reverse phase protection Water shortage (oil) protection Pump overload protection over-temperature protection Abnormal alarm buzzer |
||||
organism |
Heat medium reservesL |
6 |
6 |
8 |
|
Overall dimensionscm |
70×40×75 |
70×40×75 |
90×45×80 |
||
weightkg |
75 |
80 |
110 |
||
piping |
cooling water |
1/2” |
1/2” |
1/2” |
|
Thermal medium |
1” |
11/4” |
11/2” |
||
electricity |
power supply |
3PH 380V 50Hz |
|||
Power control |
Electromagnetic switch with protection |
||||
Maximum powerkW |
6.37 |
9.75 |
20.2 |
||
Standard Accessories |
Cooling water piping ball valve and joint Oil filled pressure gauge |
||||
Choose accessories |
Hot medium piping ball valve and joint electric heating tube temperature measuring probe |
||||
MKP series temperature control machine specification parameter table (II)
MKP Series Temperature Controller Specification Parameters Table (Ⅱ)
MKPSpecification and parameter table of series temperature control machine (II)
model |
MKP09Y |
MKP18Y |
MKP36Y |
|
control system |
Temperature control range ℃ |
0~200 |
||
Temperature controller accuracy |
1 |
|||
Operating Procedure ℃ |
Fuji, JapanPIDIntelligent Temperature Operating System |
|||
|
heating systemkW |
heating powerkW |
9(4.5×2) |
18(9×2) |
36(9×4) |
Electric heating material |
KANTHALAlloy electric heating wire and stainless steel electric heating tube |
|||
Electric heating densityw/cm |
4.5 |
4.5 |
4.5 |
|
Heating efficiency ℃/min |
24/2 |
26/2 |
28/2 |
|
heat exchanger |
Multi barrel style |
|||
energy output |
Adjustable automatically or manually |
|||
cooling system |
cooling method |
Indirect cooling |
||
Cooling efficiency ℃ |
16/1 |
16/1 |
16/1 |
|
heat exchanger |
Efficient shell and tube type |
|||
Electromagnetic valve diameter |
1/2” |
3/4” |
1” |
|
circulatory system |
pump powerkW |
0.75 |
2.20 |
4.0 |
maximum flowL/min |
90 |
180 |
280 |
|
maximum pressureMPa |
0.2 |
0.3 |
0.35 |
|
Security protection system |
Motor reverse phase protection Water shortage (oil) protection Pump overload protection over-temperature protection Abnormal alarm buzzer |
|||
organism |
Heat medium reservesL |
20 |
40 |
60 |
Overall dimensionscm |
80×55×85 |
90×55×95 |
100×60×95 |
|
weightkg |
90 |
120 |
150 |
|
piping |
cooling water |
1/2” |
3/4” |
1” |
Thermal medium |
1” |
11/4” |
11/2” |
|
electricity |
power supply |
3PH 380V 50Hz |
||
Power control |
Electromagnetic switch with protection |
|||
Maximum powerkW |
9.75 |
22.20 |
40 |
|
Standard Accessories |
Cooling water piping ball valve and joint Oil filled pressure gauge |
|||
Choose accessories |
Hot medium piping ball valve and joint electric heating tube temperature measuring probe |
|||
1. S - heat transfer medium is water Y - heat transfer medium is oil; 2. Heating and cooling efficiency testing conditions: no load; 3. Any specification between 0 and 300 ℃ can be designed and manufactured
1. S- Heat transfer medium is water Y- heating transfer medium is oill; 2. Testing conditions of heating cooling efficiency: no-load; 3. Any specificaiton between 0℃ and 300℃ can be designed and prepared.