Shanghai Jinda Biochemical Instrument Co., Ltd
Home>Products>Low pressure glass column
Low pressure glass column
Low pressure glass column
Product details

Z-series chromatography column

Z series chromatography columns are suitable for ion exchange chromatography, gel permeation chromatography and affinity chromatography. The column design is advanced, easy to install, has a small "dead volume" for elution, and has good chemical corrosion resistance. It is the best chromatography tool essential for laboratories such as medical pharmaceuticals, biochemistry, petrochemicals, and chemical analysis.

1、 Structure:

Main components--Glass pillars, top fasteners, and bottom fasteners.

Mesh size:50-500 mesh

Operating temperature:0℃-60℃

Maximum column pressure of ordinary type:0.15 × 106 pascals (equivalent to 1 kilogram of atmospheric pressure).

Pressure column pressure:5 (0.15 × 106) pascals to 8 (0.15 × 106) pascals (equivalent to 5-8 kilograms of atmospheric pressure).

Column cleaning:Soap water and detergent are suitable cleaning agents for chromatography columns. If the chromatography column is contaminated with proteins, it can be cleaned with "Jiamei" (enzyme added) detergent.

Disinfection of columns:The column is allowed to be sterilized under high pressure for 20 minutes at temperatures below 120 ℃.

2、 Attention:

1. Excluding chlorinated hydrocarbons (dichloroethane, trichloromethane). All organic solvents except acetone, ketone compounds, aliphatic lipids, and phenol can be used.

2. Do not use sodium hydroxide, hydrochloric acid, or acetic acid solutions with concentrations greater than 10%, as these solutions can damage the nylon mesh sieve.

3、 Tip:

If the compounds and solutions you are using belong to items 1 and 2 of the above precautions, please let us know so that we can provide chromatography columns with the corresponding materials according to your needs.

Z-series chromatography column conversion joint

The chromatography column conversion joint has a reasonable structure, easy installation, and beautiful appearance. It can be used for both aqueous and liquid phase analysis solutions. This product is an ideal chromatography tool when used in conjunction with our chromatography column.

advantage:

1. According to experimental needs, the length can be adjusted from 150mm to 1000mm

2. It can protect the gel surface from being damaged by liquid flow, and the chromatography liquid flows evenly, thus improving the resolution.

matters needing attention:

1. Hydrocarbons, acetone, ketones, fatty esters, and their solutions treated with chlorine cannot use this adapter.

2. Solutions such as caustic soda with a concentration exceeding 10%, hydrochloric acid with a concentration of 10%, or acetic acid with a concentration of 5% cannot use this adapter, as these solutions may damage the nylon mesh cover.

clean:

It can be cleaned with soapy water or detergent, but distillation should be avoided.

Tips:

If the compounds and solutions you are using fall under items 1 and 2 of the above precautions, please let us know so that we can provide corresponding material adapters according to your needs.

Various specifications of low-pressure glass columns

Ordinary chromatography column
Specifications Specifications Specifications Specifications Specifications Specifications Specifications Specifications
Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm
10 200 16 200 26 200 35 200 45 200 55 200 70 200 5 100
10 300 16 300 26 300 35 300 45 300 55 300 70 300
10 400 16 400 26 400 35 400 45 400 55 400 70 400
10 500 16 500 26 500 35 500 45 500 55 500 70 500
10 600 16 600 26 600 35 600 45 600 55 600 70 600
10 700 16 700 26 700 35 700 45 700 55 700 70 700
10 800 16 800 26 800 35 800 45 800 55 800 70 800
10 900 16 900 26 900 35 900 45 900 55 900 70 900
10 1000 16 1000 26 1000 35 1000 45 1000 55 1000 70 1000
Jacketed chromatography column (double conversion joint)
Specifications Specifications Specifications Specifications Specifications Specifications Specifications Specifications
Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm
10 200 16 200 26 200 35 200 45 200 55 200 50 200 5 100
10 300 16 300 26 300 35 300 45 300 55 300 50 300
10 400 16 400 26 400 35 400 45 400 55 400 50 400
10 500 16 500 26 500 35 500 45 500 55 500 50 500
10 600 16 600 26 600 35 600 45 600 55 600 50 600
10 700 16 700 26 700 35 700 45 700 55 700 50 700
10 800 16 800 26 800 35 800 45 800 55 800 50 800
10 900 16 900 26 900 35 900 45 900 55 900 50 900
10 1000 16 1000 26 1000 35 1000 45 1000 55 1000 50 1000
Stainless steel chromatography column with conversion joint
Specifications Specifications Specifications Specifications Specifications Specifications Specifications Specifications
Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm
50 500 75 500 100 500 150 500 165 500 210 500 300 500
50 600 75 600 100 600 150 600 165 600 210 600 300 600
50 700 75 700 100 700 150 700 165 700 210 700
50 800 75 800 100 800 150 800 165 800 210 800
50 900 75 900 100 900 150 900 165 900 210 900
500 1000 75 1000 100 1000 150 1000 165 1000 210 1000
Polyoxymethylene chromatography column with support and conversion joint
Specifications Specifications Specifications Specifications Specifications Specifications Specifications Specifications
Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm
50 200 75 200 100 200 150 200 165 200 210 200
50 300 75 300 100 300 150 300 165 300 210 300
50 400 75 400 100 400 150 400 165 400 210 400
50 500 75 500 100 500 150 500 165 500 210 500
Expanded chromatography column (resistant to organic solvents)
Specifications Specifications Specifications Specifications Specifications
Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm Inner diameter mm Length mm
12 200 18 200 25 200 38 200 50 200
12 300 18 300 25 300 38 300 50 300
12 400 18 400 25 400 38 400 50 400
12 500 18 500 25 500 38 500 50 500
12 600 18 600 25 600 38 600 50 600
12 750 18 750 25 750 38 750 50 750
12 1000 18 1000 25 1000 38 1000 50 1000

Explanation: Various specifications and materials of chromatography columns can be customized.

Column conversion joint
Specifications 10 16 26 35 45 55 70 75 100 150 165
ordinary
thread
Stainless steel extended thread
Expansion chromatography column conversion joint (threaded)
specifications 12 18 25 38 50 75
Chromatography column sieve
Specifications 10 16 26 35 45 55/50 70 75 100 150 165
Single price yuan 200-300 mesh 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 14.00 20.00 21.00
400 mesh 5.00 6.00 8.00 9.00 10.00 11.00 12.00 13.00 16.00 26.00 27.00
500 mesh 6.00 7.00 9.00 10.00 11.00 12.00 14.00 16.00 18.00 27.00 28.00
Table of mesh size and pore size (um) conversion for sieve mesh
Number of eyes 50 100 150 200 250 300 400 500
Aperture (um) 326 133 85 78 55 50 40 25
Column attachments for chromatography
Specifications 10 16 26 35 45 55/50 70 100 150 165 210
one
price
(Yuan)
Rubber gasket 6.00 7.00 9.00 11.00 13.00 15.00 17.00
Silicone gasket 6.00 7.00 9.00 11.00 13.00 15.00 17.00 35.00 45.00 55.00 65.00
rubber stopper 4.00 4.00 4.00 6.00 7.00 7.00 7.00 10.00 10.00 10.00 15.00
Silicone stopper 4.00 4.00 4.00 6.00 7.00 7.00 7.00 10.00 10.00 10.00 15.00
Nut cap 4.00 4.00 4.00 6.00 7.00 7.00 7.00 10.00 10.00 10.00 10.00
rubber ring 8.00 9.00 11.00 14.00 18.00 20.00 22.00 30.00 40.00 50.00 60.00
Guide Ring 12.00 14.00 16.00 18.00 20.00 22.00 27.00
Hoop ring 6.00 7.00 8.00 10.00 15.00 15.00 20.00 100.00 200.00 250.00 300.00
Bottom screw 50.00 70.00 80.00 80.00 100.00 100.00

Filling bottles of various specifications

Gel filling bottle
Used for ordinary chromatography columns
Inner diameter (mm) 10 16 26 35 45 55 70
Used for expanding the chromatography column
Inner diameter (mm) 12 18 25 38 50 75
Used for jacketed chromatography columns
Inner diameter (mm) 10 16 26 35 45 55 70
Used for flange chromatography columns
Inner diameter (mm) 50 75 100 150 165 210 300
other:

1. Connector

a. M6 connector compatible with AKTA machine:

Price: 30.00 yuan/set

b. Customized two-way connectors and other connectors:

The price ranges from 30.00 to 100.00 yuan

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!