Z-series chromatography column

Z series chromatography columns are suitable for ion exchange chromatography, gel permeation chromatography and affinity chromatography. The column design is advanced, easy to install, has a small "dead volume" for elution, and has good chemical corrosion resistance. It is the best chromatography tool essential for laboratories such as medical pharmaceuticals, biochemistry, petrochemicals, and chemical analysis.
1、 Structure:
Main components--Glass pillars, top fasteners, and bottom fasteners.
Mesh size:50-500 mesh
Operating temperature:0℃-60℃
Maximum column pressure of ordinary type:0.15 × 106 pascals (equivalent to 1 kilogram of atmospheric pressure).
Pressure column pressure:5 (0.15 × 106) pascals to 8 (0.15 × 106) pascals (equivalent to 5-8 kilograms of atmospheric pressure).
Column cleaning:Soap water and detergent are suitable cleaning agents for chromatography columns. If the chromatography column is contaminated with proteins, it can be cleaned with "Jiamei" (enzyme added) detergent.
Disinfection of columns:The column is allowed to be sterilized under high pressure for 20 minutes at temperatures below 120 ℃.
2、 Attention:
1. Excluding chlorinated hydrocarbons (dichloroethane, trichloromethane). All organic solvents except acetone, ketone compounds, aliphatic lipids, and phenol can be used.
2. Do not use sodium hydroxide, hydrochloric acid, or acetic acid solutions with concentrations greater than 10%, as these solutions can damage the nylon mesh sieve.
3、 Tip:
If the compounds and solutions you are using belong to items 1 and 2 of the above precautions, please let us know so that we can provide chromatography columns with the corresponding materials according to your needs.
Z-series chromatography column conversion joint

The chromatography column conversion joint has a reasonable structure, easy installation, and beautiful appearance. It can be used for both aqueous and liquid phase analysis solutions. This product is an ideal chromatography tool when used in conjunction with our chromatography column.
advantage:
1. According to experimental needs, the length can be adjusted from 150mm to 1000mm
2. It can protect the gel surface from being damaged by liquid flow, and the chromatography liquid flows evenly, thus improving the resolution.
matters needing attention:
1. Hydrocarbons, acetone, ketones, fatty esters, and their solutions treated with chlorine cannot use this adapter.
2. Solutions such as caustic soda with a concentration exceeding 10%, hydrochloric acid with a concentration of 10%, or acetic acid with a concentration of 5% cannot use this adapter, as these solutions may damage the nylon mesh cover.
clean:
It can be cleaned with soapy water or detergent, but distillation should be avoided.
Tips:
If the compounds and solutions you are using fall under items 1 and 2 of the above precautions, please let us know so that we can provide corresponding material adapters according to your needs.
Various specifications of low-pressure glass columns
Ordinary chromatography column
Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | ||||||||||||||||
Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | ||||||||
10 | 200 | 16 | 200 | 26 | 200 | 35 | 200 | 45 | 200 | 55 | 200 | 70 | 200 | 5 | 100 | ||||||||
10 | 300 | 16 | 300 | 26 | 300 | 35 | 300 | 45 | 300 | 55 | 300 | 70 | 300 | ||||||||||
10 | 400 | 16 | 400 | 26 | 400 | 35 | 400 | 45 | 400 | 55 | 400 | 70 | 400 | ||||||||||
10 | 500 | 16 | 500 | 26 | 500 | 35 | 500 | 45 | 500 | 55 | 500 | 70 | 500 | ||||||||||
10 | 600 | 16 | 600 | 26 | 600 | 35 | 600 | 45 | 600 | 55 | 600 | 70 | 600 | ||||||||||
10 | 700 | 16 | 700 | 26 | 700 | 35 | 700 | 45 | 700 | 55 | 700 | 70 | 700 | ||||||||||
10 | 800 | 16 | 800 | 26 | 800 | 35 | 800 | 45 | 800 | 55 | 800 | 70 | 800 | ||||||||||
10 | 900 | 16 | 900 | 26 | 900 | 35 | 900 | 45 | 900 | 55 | 900 | 70 | 900 | ||||||||||
10 | 1000 | 16 | 1000 | 26 | 1000 | 35 | 1000 | 45 | 1000 | 55 | 1000 | 70 | 1000 |
Jacketed chromatography column (double conversion joint)
Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | |||||||||||||||
Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | |||||||
10 | 200 | 16 | 200 | 26 | 200 | 35 | 200 | 45 | 200 | 55 | 200 | 50 | 200 | 5 | 100 | |||||||
10 | 300 | 16 | 300 | 26 | 300 | 35 | 300 | 45 | 300 | 55 | 300 | 50 | 300 | |||||||||
10 | 400 | 16 | 400 | 26 | 400 | 35 | 400 | 45 | 400 | 55 | 400 | 50 | 400 | |||||||||
10 | 500 | 16 | 500 | 26 | 500 | 35 | 500 | 45 | 500 | 55 | 500 | 50 | 500 | |||||||||
10 | 600 | 16 | 600 | 26 | 600 | 35 | 600 | 45 | 600 | 55 | 600 | 50 | 600 | |||||||||
10 | 700 | 16 | 700 | 26 | 700 | 35 | 700 | 45 | 700 | 55 | 700 | 50 | 700 | |||||||||
10 | 800 | 16 | 800 | 26 | 800 | 35 | 800 | 45 | 800 | 55 | 800 | 50 | 800 | |||||||||
10 | 900 | 16 | 900 | 26 | 900 | 35 | 900 | 45 | 900 | 55 | 900 | 50 | 900 | |||||||||
10 | 1000 | 16 | 1000 | 26 | 1000 | 35 | 1000 | 45 | 1000 | 55 | 1000 | 50 | 1000 |
Stainless steel chromatography column with conversion joint
Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | |||||||||||||||
Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | |||||||
50 | 500 | 75 | 500 | 100 | 500 | 150 | 500 | 165 | 500 | 210 | 500 | 300 | 500 | |||||||||
50 | 600 | 75 | 600 | 100 | 600 | 150 | 600 | 165 | 600 | 210 | 600 | 300 | 600 | |||||||||
50 | 700 | 75 | 700 | 100 | 700 | 150 | 700 | 165 | 700 | 210 | 700 | |||||||||||
50 | 800 | 75 | 800 | 100 | 800 | 150 | 800 | 165 | 800 | 210 | 800 | |||||||||||
50 | 900 | 75 | 900 | 100 | 900 | 150 | 900 | 165 | 900 | 210 | 900 | |||||||||||
500 | 1000 | 75 | 1000 | 100 | 1000 | 150 | 1000 | 165 | 1000 | 210 | 1000 |
Polyoxymethylene chromatography column with support and conversion joint
Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | Specifications | |||||||||||||||
Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | |||||||
50 | 200 | 75 | 200 | 100 | 200 | 150 | 200 | 165 | 200 | 210 | 200 | |||||||||||
50 | 300 | 75 | 300 | 100 | 300 | 150 | 300 | 165 | 300 | 210 | 300 | |||||||||||
50 | 400 | 75 | 400 | 100 | 400 | 150 | 400 | 165 | 400 | 210 | 400 | |||||||||||
50 | 500 | 75 | 500 | 100 | 500 | 150 | 500 | 165 | 500 | 210 | 500 |
Expanded chromatography column (resistant to organic solvents)
Specifications | Specifications | Specifications | Specifications | Specifications | |||||||||
Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | Inner diameter mm | Length mm | ||||
12 | 200 | 18 | 200 | 25 | 200 | 38 | 200 | 50 | 200 | ||||
12 | 300 | 18 | 300 | 25 | 300 | 38 | 300 | 50 | 300 | ||||
12 | 400 | 18 | 400 | 25 | 400 | 38 | 400 | 50 | 400 | ||||
12 | 500 | 18 | 500 | 25 | 500 | 38 | 500 | 50 | 500 | ||||
12 | 600 | 18 | 600 | 25 | 600 | 38 | 600 | 50 | 600 | ||||
12 | 750 | 18 | 750 | 25 | 750 | 38 | 750 | 50 | 750 | ||||
12 | 1000 | 18 | 1000 | 25 | 1000 | 38 | 1000 | 50 | 1000 |
Explanation: Various specifications and materials of chromatography columns can be customized.
Column conversion joint
Specifications | 10 | 16 | 26 | 35 | 45 | 55 | 70 | 75 | 100 | 150 | 165 | ||||||||||||
ordinary | |||||||||||||||||||||||
thread | |||||||||||||||||||||||
Stainless steel extended thread |
Expansion chromatography column conversion joint (threaded)
specifications | 12 | 18 | 25 | 38 | 50 | 75 | |||||||
Chromatography column sieve
Specifications | 10 | 16 | 26 | 35 | 45 | 55/50 | 70 | 75 | 100 | 150 | 165 | ||||||||||||
Single price yuan | 200-300 mesh | 4.00 | 5.00 | 6.00 | 7.00 | 8.00 | 9.00 | 10.00 | 11.00 | 14.00 | 20.00 | 21.00 | |||||||||||
400 mesh | 5.00 | 6.00 | 8.00 | 9.00 | 10.00 | 11.00 | 12.00 | 13.00 | 16.00 | 26.00 | 27.00 | ||||||||||||
500 mesh | 6.00 | 7.00 | 9.00 | 10.00 | 11.00 | 12.00 | 14.00 | 16.00 | 18.00 | 27.00 | 28.00 |
Table of mesh size and pore size (um) conversion for sieve mesh
Number of eyes | 50 | 100 | 150 | 200 | 250 | 300 | 400 | 500 | |||||||||
Aperture (um) | 326 | 133 | 85 | 78 | 55 | 50 | 40 | 25 |
Column attachments for chromatography
Specifications | 10 | 16 | 26 | 35 | 45 | 55/50 | 70 | 100 | 150 | 165 | 210 | ||||||||||||
one price (Yuan) |
Rubber gasket | 6.00 | 7.00 | 9.00 | 11.00 | 13.00 | 15.00 | 17.00 | |||||||||||||||
Silicone gasket | 6.00 | 7.00 | 9.00 | 11.00 | 13.00 | 15.00 | 17.00 | 35.00 | 45.00 | 55.00 | 65.00 | ||||||||||||
rubber stopper | 4.00 | 4.00 | 4.00 | 6.00 | 7.00 | 7.00 | 7.00 | 10.00 | 10.00 | 10.00 | 15.00 | ||||||||||||
Silicone stopper | 4.00 | 4.00 | 4.00 | 6.00 | 7.00 | 7.00 | 7.00 | 10.00 | 10.00 | 10.00 | 15.00 | ||||||||||||
Nut cap | 4.00 | 4.00 | 4.00 | 6.00 | 7.00 | 7.00 | 7.00 | 10.00 | 10.00 | 10.00 | 10.00 | ||||||||||||
rubber ring | 8.00 | 9.00 | 11.00 | 14.00 | 18.00 | 20.00 | 22.00 | 30.00 | 40.00 | 50.00 | 60.00 | ||||||||||||
Guide Ring | 12.00 | 14.00 | 16.00 | 18.00 | 20.00 | 22.00 | 27.00 | ||||||||||||||||
Hoop ring | 6.00 | 7.00 | 8.00 | 10.00 | 15.00 | 15.00 | 20.00 | 100.00 | 200.00 | 250.00 | 300.00 | ||||||||||||
Bottom screw | 50.00 | 70.00 | 80.00 | 80.00 | 100.00 | 100.00 |
Filling bottles of various specifications
Gel filling bottle
Used for ordinary chromatography columns
Inner diameter (mm) | 10 | 16 | 26 | 35 | 45 | 55 | 70 |
Used for expanding the chromatography column
Inner diameter (mm) | 12 | 18 | 25 | 38 | 50 | 75 |
Used for jacketed chromatography columns
Inner diameter (mm) | 10 | 16 | 26 | 35 | 45 | 55 | 70 |
Used for flange chromatography columns
Inner diameter (mm) | 50 | 75 | 100 | 150 | 165 | 210 | 300 |
other:
1. Connector
a. M6 connector compatible with AKTA machine:
Price: 30.00 yuan/set
b. Customized two-way connectors and other connectors:
The price ranges from 30.00 to 100.00 yuan