Lovibond COD analyzer
Measurement range: 0 to 150 mg/L (ppm) O2, 0 to 1500 mg/L (ppm) O2, 0 to 15000 mg/L (ppm) O2
Detection principle: The potassium dichromate method (K2CrO7) is used to determine the chemical oxygen demand (COD). The pre made COD reagent complies with the Standard Method 5220D and US EPA 410.4 standards. The dedicated heating digestion device is made of heat-resistant and corrosion-resistant materials, and can digest 24 samples simultaneously. It has overheating protection function to ensure safe and stable use.
Unique SMD microcomputer control technology, high-quality narrow band filter, temperature compensated LED optical system, built-in reaction timer to ensure consistency between sample measurement and user results, compact overall design, waterproof sample pool to ensure fast and accurate measurement, good reproducibility, calibration function and built-in software adjustment function, applied in scientific research, metrology for sample testing and identification.
Equipped with unique SMD microcomputer control technology, high-performance narrowband filter and temperature compensated LED light source system, new waterproof design, exquisite portability, and background light display screen.
▷ Factory and user-defined dual calibration function, automatic memory of the last zero calibration, no need for frequent zero calibration, good GLP function, automatic shutdown setting.
Unique IRiM infrared data transmitter [recommended ET214050] design, 16 sets of data storage, can be accessed and read at any time, convenient for on-site data organization and recording, and easy to connect with a computer for data transmission.
technical specifications |
MD100/MD200/ET99718 |
measuring range |
0 to 150 mg/L(ppm)O2 、0 to 1500 mg/L(ppm)O2、0 to 15000 mg/L(ppm)O2 |
resolution |
1 mg/L(ppm)、1 mg/L(ppm)、10 mg/L(ppm) |
Accuracy @ 20 ° C |
±3.5 % F.S. |
optical system |
Waterproof sample pool, temperature compensated LED optical system; |
Method standards |
Reference water and wastewater standard methods, 18th edition, potassium dichromate/sulfuric acid colorimetric method [ISO 15705:2002] |
Calibration Mode |
Automatic zero point calibration, factory calibration, and user-defined dual calibration modes |
data management |
16 sets of data storage, which can be accessed at any time; Cooperate with ET214050 IRiM infrared data transmitter for convenient data transmission with PC |
Power Mode |
4 x 1.5AAA battery, automatically shuts down after 10 minutes without operation, LCD backlight |
application environment |
5 to 40 ° C, RH: 30 to 90% non condensing |
Dimension |
Host size: 155 × 75 × 35mm, host weight: 260g |
Certification standards |
CE certification, IP68 (under 0.1m conditions, 1 hour) |
Technical specifications of heating and digestion processor |
|
Dissolve quantity |
Can simultaneously digest 24 samples, with a digestion aperture of 16mm, suitable for international custom tube reagents |
Temperature setting |
70, 100, 120, 150 ° C four gear selection |
time control |
30, 60, 120 minutes or continuous heating. After digestion is complete, it will automatically turn off with a prompt sound |
temperature range |
Pt100A built-in temperature probe, accuracy: ± 0.3 ° C |
Protection type |
ABS heat-resistant and corrosion-resistant material, temperature automatic control, anti overheating system protection |
Power Mode |
230 V/50-60 Hz or 115 V/50-60 Hz; 40W Manually switch between 110 V and 220 V through the voltage switch on the back |
application environment |
10 to 40 ° C, RH: 85% Max |
Dimension |
Host size: 219 × 171 × 248mm, host weight: 3.9Kg |
Certification standards |
CE certification |
|
- photometer
- COD reactor RD 125
- COD colorimetric cup test (0-150 mg/l&0-1500 mg/l)
- cuvettes
- Operating instructions
- Warranty Statement
Recommend purchasing accessories |
ET99955 customized specialized chemical oxygen demand [COD-LR] reagent, applicable range: 0 to 150 mg/L (ppm) |
ET99974 customized specialized chemical oxygen demand [COD-MR] reagent, applicable range: 0 to 1500 mg/L (ppm) |
|
ET99106 customized chemical oxygen demand [COD-MR] reagent, applicable range: 0 to 15000 mg/L (ppm) |
|
ET2420803 customized special COD standard solution, standard value: 100mg/L, specification: 30mL |
|
ET2420804 customized special COD standard solution, standard value: 500mg/L, specification: 30mL |
|
ET2420805 customized special COD standard solution, standard value: 5000mg/L, specification: 10mL |
|
ET214050 customized dedicated IRiM infrared data transmitter, USB interface, suitable for data transmission to a computer for data, management, and analysis |
|
ET197635 customized glass colorimetric dish cleaning cloth, packaging: 4 pieces/group |
|
ET418957 customized ∅ 16mm ten hole colorimetric dish test tube rack, suitable for heating and cooling of tube reagents |