Light aging test chamberProduct Introduction
The UV box can reproduce the hazards that occur outdoors for months or years in a matter of days or weeks. The types of hazards include fading, discoloration, loss of gloss, powdering, cracking, turbidity, bubbles, brittleness, strength, deterioration, and oxidation. This test chamber is suitable for evaluating the UV resistance performance of materials such as storage polymer materials, protective layers, photovoltaic modules, etc
Box structure: Box shell material: SUS stainless steel plate spray treated; Inner liner material: SUS stainless steel plate;
Box cover material: SUS stainless steel plate with spray coating treatment;
Install a total of 8 UV-A or UV-B ultraviolet lamps on both sides of the studio;
The heating method is the inner pot sink type heating, which heats up quickly and has a uniform temperature distribution;
The box cover is a double-sided flip cover, which can be opened and closed easily and freely;
The inner tank water level automatically replenishes to prevent the heating tube from burning out and being damaged;
The sample holder is made of stainless steel or aluminum alloy;
The bottom of the test chamber adopts high-quality fixed PU movable wheels;
The drainage system uses vortex and U-shaped sedimentation devices for drainage;
The surface of the sample is parallel to the plane of the ultraviolet lamp;
The spray type equipment is equipped with automatic nozzles inside, and the water pressure can be adjusted;
If the lamp is on, once the door of the box is opened, the machine will automatically cut off the power supply to the lamp and enter a balanced state for cooling to prevent harm to the human body;
Over temperature protection inside the box. When the temperature inside the box is too high, the machine will automatically cut off the power and enter a balanced state for cooling
Light aging test chamberThe control system:
The temperature and humidity control instrument adopts a fully imported high-precision digital display microcomputer integrated controller from South Korea; Accuracy: 0.1 ℃ (display range); Resolution: ± 0.1 ℃; Temperature sensor: PT100 platinum resistance thermometer;
Control mode: thermal balance temperature and humidity control mode;
The temperature and humidity control adopts the coordinated control of the P.I.D+S.S.R system on the same channel;
Non fuse protection switch; Overtemperature; Low water level; Overload; electric leakage; Fully sheathed terminal block; Automatic shutdown and other protections;
The model and parameters
Studio size: 450 × 1170 × 500mm;
Dimensions: 580 × 1280 × 1450mm;
Temperature range: RT+10 ℃~70 ℃;
Humidity range: 90-98% R · H;
Humidity uniformity: ± 2%;
Temperature uniformity: ± 2 ℃;
Temperature fluctuation: ± 0.5 ℃;
Humidity fluctuation: ± 2%;
Standard specimen size: 75 × 150mm or 75 × 300mm (special specifications need to be specified in the contract);
Water depth requirement for the sink: 25mm, automatic control;
Effective irradiation area: 900 × 210mm;
Ultraviolet wavelength: UV-A wavelength range is 315-400nm; UV-B wavelength range is 280-315nm;
Test time: adjustable from 0 to 999H;
Blackboard temperature: 40 ℃~65 ℃;
UV light and condensation time can be alternately adjusted;
We can also customize non-standard test chambers according to customer needs laboratory
Compliant with standards
This UV accelerated weathering testing machine is suitable for performance reliability testing of various industrial products. It is designed and manufactured in accordance with the corresponding standard clauses such as GB/T14522-93 "National Standard of the People's Republic of China - Plastic, Coating, and Rubber Materials for Mechanical Industry Products - Artificial Climate Acceleration Test Method" GB/T16585-1996 "National Standard of the People's Republic of China - Vulcanized Rubber Artificial Climate Aging (Fluorescent UV Lamp) Test Method" and GB/T16422.3-1997 "Plastic Laboratory Light Source Exposure Test Method";
Meets testing standards: ASTM D4329, D499, D4587, D5208, G154, G53; ISO 4892-3、ISO 11507; EN 534; prEN 1062-4、 BS 2782; JIS D0205; All current light aging test standards such as SAE J2020.